• Title/Summary/Keyword: FE analysis method

Search Result 1,530, Processing Time 0.029 seconds

The formability of high strength steel plate applied TRB for stamping (스탬핑용 고강도강 TRB 판재의 성형 특성)

  • Park, Hyun-kyung;Jeong, Ji-Won;Lee, Gyung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.184-189
    • /
    • 2018
  • Recently, research on lightweight automobiles is increasing continuously to respond to the high safety standards and environmental regulations. The application of high strength steel is one of the effective methods for developing lightweight car bodies. A TWB (Tailor Welded Blank) is major method that allows partial high strength with light weighting using a multi-thickness and multi-material welded blank. On the other hand, additional welding process is required to prepare the blank and quality control for the welding process also required. To secure this point, the TRB (Tailor Rolled Blank) method was suggested. In the TRB method, the thickness of sheet is controlled by the rolling presses and the production efficiency is much higher than welding in TWB methods. In this study, the formability of high strength TRB steel plate was analyzed to examine the rolling effect of the blank. The formability of the specimen was tested using 0.8 and 1 mm thick steel sheets for the TRB plate. The strain was analyzed by the digital image sensing of grid markings on the specimen and the forming limit diagram was calculated. An Erichsen test for the 0.8 and 1 mm thick TRB specimens was carried out and the formability was investigated by comparing with FE analysis.

Simultaneous Concentration and Determination of Several Trace Elements in Sea Water by Ce(OH)$_3$ Coprecipitation (Ce(OH)$_3$의 공침부선에 의한 해주중 몇 가지 미량원소의 동시 농축 및 정량)

  • Woo-Sik Sung;Hee-Seon Choi;Young-Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.327-333
    • /
    • 1993
  • A method was developed for the determination of trace elements in seawater by precipitate flotation preconcentration and subsequent flame atomic absorption detection. In order to quantitatively coprecipitate trace ions such as Cd(II), CuI(II), Fe(III), Mn(II), Pb(II) and Pd(II), 2.0 ml of 1.0M cerium(III) solution was added to 1.0l of seawater and the pH was adjusted to 9.5 with 5.0 M sodium hydroxide solution while stirring with a magnetic stirrer. The precipitate was floated with the aid of surfactant solution (1.0 ml of 0.3% sodium oleate) by bubbling nitrogen gas through a porous (No. 4) fritted glass disk. The floats was collected in a small Erlenmeyer flask by suction. The washed precipitate was dissolved in 8.0 M nitric acid and marked with deionized water in the volumetric flask of 10.0 ml. The analyte was determined by measuring the atomic absorbances in 100-fold concentrated solution. Above all analytes in Kangnung (East Sea) and Kanghwado (West Sea) sea waters were found to be under the detection limit of this method. The recoveries of over 92% for all analytes spiked into seawater samples showed that this method was applicable to the analysis of real seawater.

  • PDF

Antibacterial, Antioxidant Activities of Acer tegmentosum Maxim Ethanol Extract Against Staphylococcus aureus (벌나무 추출물의 황생포도상구균에 대한 항균 효과와 항산화 활성)

  • Jin-Woo Hwang;Chan Hwi Park;Hae-Yeon An;Ye-Won Jang;Hyun Kang;Sung-Gyu Lee
    • Journal of Plant Biotechnology
    • /
    • v.49 no.4
    • /
    • pp.339-346
    • /
    • 2022
  • This study investigates the antibacterial and antioxidant activities of the ethanol extract of Acer tegmentosum Maxim (EATM) against Staphylococcus aureus. The total polyphenol and flavonoid content, 1,1-diphenyl-2-picryl hydrazyl (DPPH) and 2,2'-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) radical scavenging effect, and reducing power of the ferric reducing antioxidant power (FRAP) method were measured to verify the antioxidant activity of the EATM. The antibacterial activity against S. aureus using the EATM was verified by the paper disc method, minimum inhibitory concentration (MIC), and minimum bactericidal concentration (MBC) methods. The total polyphenol and flavonoid contents were 266.66 ㎍ GAE/mg and 6.46 ㎍ QE/mg, respectively. The DPPH and ABTS radical scavenging activity showed a concentration-dependent scavenging activity. The RC50 values of the EATM were 21.49 and 12.81 ㎍/mL, respectively. A FRAP analysis was conducted for evaluating the reducing power of the EATM and an efficacy of 0.73 ± 0.19 mM FeSO4 E/mg was observed. The antibacterial activity of EATM against S. aureus, determined using the paper disc method, showed an inhibitory ring of 3 mm at 2 mg. The MIC was confirmed at a concentration of ≥ 16 mg/mL, while the MBC was confirmed at 32 mg/mL. As the EATM shows antioxidant and antibacterial activities against S. aureus, it can be used as an effective antidote against atopic dermatitis.

Rotordynamic Analysis of a Dry Vacuum Pump Rotor-Bearing System for High-Speed Operation (고속 운전용 건식진공펌프 로터-베어링 시스템의 회전체동역학 해석)

  • Lee, An-Sung;Lee, Dong-Hwan;Kim, Byung-Ok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.523-530
    • /
    • 2006
  • A rotordynamic analysis was performed with a dry vacuum pump, which is a major equipment in modern semiconductor and LCD manufacturing processes. The system is composed of screw rotors, lobes picking air, helical gears, driving motor, and support rolling element hearings of rotors and motor. The driving motor-screw rotor system has a rated speed of 6,300rpm, and was modeled utilizing a rotordynamic FE method for analysis, which was verified through the results of its 3-D finite element model. As loadings on the bearings due to the gear action were significant in the system considered, each resultant bearing load was calculated determinately and indeterminately by considering the generalized forces of the gear action as veil as the rotor itself. Each resultant hearing loading was used in calculating each stiffness of rolling element bearings. Design goals are to achieve wide separation margins of critical speeds and favorable unbalance responses of the rotor in the operating range. Then, a complex rotordynamic analysis of the system was carried out to evaluate its forward synchronous critical speeds, whirl natural frequencies and mode shapes, and unbalance responses under various unbalance locations. Results show that the entire system is well designed in the operating range. In addition, the procedure of rotordynamic analysis for dry vacuum pump rotor-bearing system was proposed and established.

  • PDF

A Rotordynamic Analysis of Dry Vacuum Pump Rotor-Bearing System for High-Speed Operation (고속 운전용 건식진공펌프 로터-베어링 시스템의 전체동역학 해석)

  • Kim, Byung-Ok;Lee, An-Sung;Noh, Myung-Keun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.3 s.42
    • /
    • pp.47-54
    • /
    • 2007
  • A rotordynamic analysis was performed with a dry vacuum pump, which is a major equipment in modem semiconductor and LCD manufacturing processes. The system is composed of screw rotors, lobes picking air, helical gears, driving motor, and support rolling element bearings of rotors and motor. The driving motor-screw rotor system has a rated speed of 6,300rpm, and was modeled utilizing a rotordynamic FE method for analysis, which was verified through the results of its 3-D finite element model. As loadings on the bearings due to the gear action were significant in the system considered, each resultant bearing load was calculated determinately and indeterminately by considering the generalized forces of the gear action as well as the rotor itself. Each resultant bearing loading was used in calculating each stiffness of rolling element bearings. Design goals are to achieve wide separation margins of critical speeds and favorable unbalance responses of the rotor in the operating range. Then, a complex rotordynamic analysis of the system was carried out to evaluate its forward synchronous critical speeds, whirl natural frequencies and mode shapes, and unbalance responses under various unbalance locations. Results show that the entire system is well designed in the operating range. In addition, the procedure of rotordynamic analysis for dry vacuum pump rotor-bearing system was proposed and established.

Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis

  • Geramizadeh, Maryam;Katoozian, Hamidreza;Amid, Reza;Kadkhodazadeh, Mahdi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • Objectives: This study aimed to optimize the thread depth and pitch of a recently designed dental implant to provide uniform stress distribution by means of a response surface optimization method available in finite element (FE) software. The sensitivity of simulation to different mechanical parameters was also evaluated. Materials and Methods: A three-dimensional model of a tapered dental implant with micro-threads in the upper area and V-shaped threads in the rest of the body was modeled and analyzed using finite element analysis (FEA). An axial load of 100 N was applied to the top of the implants. The model was optimized for thread depth and pitch to determine the optimal stress distribution. In this analysis, micro-threads had 0.25 to 0.3 mm depth and 0.27 to 0.33 mm pitch, and V-shaped threads had 0.405 to 0.495 mm depth and 0.66 to 0.8 mm pitch. Results: The optimized depth and pitch were 0.307 and 0.286 mm for micro-threads and 0.405 and 0.808 mm for V-shaped threads, respectively. In this design, the most effective parameters on stress distribution were the depth and pitch of the micro-threads based on sensitivity analysis results. Conclusion: Based on the results of this study, the optimal implant design has micro-threads with 0.307 and 0.286 mm depth and pitch, respectively, in the upper area and V-shaped threads with 0.405 and 0.808 mm depth and pitch in the rest of the body. These results indicate that micro-thread parameters have a greater effect on stress and strain values.

Nonlinear Tensile Behavior Analysis of Torque-controlled Expansion Anchors Using Finite Element Analysis (유한요소해석을 활용한 비틀림 제어 확장앵커의 비선형 인장거동 특성 분석)

  • Bang, Jin Soo;Youn, Ilro;Kwon, Yangsu;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.91-99
    • /
    • 2020
  • Post-installed anchors were widely used due to its workable benefits. Regarding the resistance performance of anchors, the critical edge distance is presented to minimize the impact of concrete splitting. In the case of actual anchors, however, it is difficult to obtain the ideal edge distance. The purpose of this study is to identify resistance performance and behavior characteristics that contain complex elements such as concrete crack occurring under tensile load. Tensile tests were conducted based on the standard method. Failure shape and the resistance characteristics that do not have the critical edge distance were derived by tensile load. Parametric analysis according to the boundary condition was performed to simulate the actual tensile behavior, through a nonlinear finite element model based on the specimen. Consequently therefore, verifying analysis results the resistance mechanism can be applied through boundary conditions.

Spectrophotometric Determination of Aluminium Ion in Drinking Water by Flow Injection Analysis (흐름주입분석법에 의한 음용수 중 알루미늄 이온의 분광광도법 정량)

  • Choi, Yong-Wook;Jin, Jae-Young
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.5
    • /
    • pp.422-428
    • /
    • 2000
  • Optimum analytical conditions of the aluminium ion were established by flow injection analysis. Eriochrome Cyanine R(ECR) dye reacts with the aluminium ion at pH 6.0 to form a complex that exhibits maximum absorption at 535 nm. Reaction conditions including the mixing and the reaction coil length, the concentration and the pH of the buffer solutio, temperature, and injection loop volume were optimized to intro-duce this reaction into flow injection analysis. The results were as follows. A mixing coil length of 0.5 m and a reaction coil length of 4.0 m, the pH 6.0 and 1M of acetate buffer solution, the ECR concentration of 0.56 mM, the reaction temperature of 40$^{\circ}C$, the injection loop volume of 300${\mu}L$ were chosen as optimum conditions. Under these conditions the detection limit of the aluminiumion was less than 0.05 mg/L and the repeatability was better than 1%. A sampling frequency of 24 times for an hour was achieved. Interfering ions such as $F^-$, HP$O_4^{2-}$, $Fe^{2+}$, $Fe^{3+}$, $Mn^{2+}$, and other anions were tested, interference did not occur up to 1,000mg/L of ion concentration and up to 2,CO0mg/L of sulfate ion con-centration. This method was applied for the determination of aluminium ion in tap water and ground water of Jeonju and the Gochang area. The results showed that the aluminium residual in tap water of the Jeonju area was at a mean of 0.478mg/L and that in tap water of the Gochang area was at a mean of 0.278mg/L. Aluminium ion residual of the tap waters in the Jeonju area was higher level than that in the Gochang area. Aluminium residual in the ground water of the Jeonju area was 0.386 mg/L and was lower compared to 0.564 mg/L for the Gochang area.

  • PDF

Characterization of manganese oxide supercapacitors using carbon cloth (Carbon Cloth을 이용한 이산화망간 슈퍼커패시터 특성 연구)

  • Lee, Seung Jin;Kim, Chihoon;Ji, Taeksoo
    • Journal of Digital Contents Society
    • /
    • v.18 no.6
    • /
    • pp.1199-1205
    • /
    • 2017
  • Global energy consumption is rapidly increasing yearly due to drastic industrial advances, requiring the development of new energy storage devices. For this reason, supercapacitors with fast charge-discharge, long life cycle and high power density is getting attention, and have been considered as one of the potential energy storage systems. In this research, we developed a supercapacitor that consists of amorphous manganese oxide($MnO_2$) electrodes deposited onto carbon cloth substrates using the hydrothermal method. The Fe-doped amorphous $MnO_2$ samples were characterized by X-ray diffraction(XRD), Energy Dispersive X-ray spectroscopy(EDX), as well as scanning electron microscopy(SEM). The electrochemical analysis of the prepared samples were performed using cyclic voltammetry and galvanostatic charge-discharge measurements in 1M $Na_2SO_4$ electrolyte. The test results demonstrate that the supercapacitor based on the Fe-doped amorphous $MnO_2$ electrodes has a specific capacitance as high as 163F/g at 1A/g current density, and good cycling stability of 87.34% capacitance retention up to 1000 cycles.

A Study on Nutrient Intake, Food Behavior and Health Conditions according to Food Intake Diversity in the Elderly in a Local City (식품 섭취의 다양성에 따른 중소도시 노인의 영양 및 식행동, 건강상태에 관한 연구)

  • 김인숙;유현희;김윤숙
    • Korean Journal of Community Nutrition
    • /
    • v.6 no.2
    • /
    • pp.205-217
    • /
    • 2001
  • This survey was carried out to study the difference of nutrient intake, food behavior and health condition according to food intake diversity in the elderly(age 65 year over and 74 year under) in a local city. A diet survey with one day 24-recall method was used for 216 subjects(65 male & 151 female). Based on a food intake diversity examination, including an evaluation of KDDS(Korean's Dietary Diversity Score ; counts the number of food groups consumed daily from total five food groups(cereal, meat, vegetable, dairy, and oil groups)), Meal Balance(apply the KDDS at breakfast, lunch and dinner), and DVS(Dietary Variety Score ; total number of foods consumed), subjects were clustered according to food intake diversity. Food intake diversity patterns of male and female clusters were classified each into threes(Male-low group(24.6%), middle group(33.8%), and high group(41.5%)/Female low group(41.7%) middle group(37.1%), and high group(21.2%). The averages of KDDS, Meal Balance and DVS were 3.0, 7.5, 14.8 in the male middle group, and 4.5, 10.2, 25.7 in the male high group, 2.7, 6.3, 14.3 in the female low group, 4.0, 8.6, 18.0 in the female middle group, and 4.5, 10.5, 25.7 in the female high group respectively. The average dairy intake of nutrients below the RDA were energy, protein, Ca, Fe, Vitamin A, Vitamin B$_2$and niacin in the male low group, energy, protein, Ca, Fe, Vitamin A, Vitamin B$_2$in the male middle group and energy, Ca, Vitamin B$_2$in the male high group but a little. Also the female low group had intakes of all nutrients except Vitamin C, the middle group had intakes of energy, protein, Ca, Fe, Vitamin A, Vitamin B$_2$, and the female high group had intakes of energy, Ca, Vitamin A below the RDA respectively. Food intake diversity increasing, nutrient intake, food behavior and health condition proved to be good. This study explored the usefulness of cluster analysis in identifying food intake diversity of three groups of the elderly in relation to their nutrient intake, food behavior and health conditions.

  • PDF