• Title/Summary/Keyword: FDG PET-CT

Search Result 412, Processing Time 0.029 seconds

A Case of Functionary Cystic Parathyroid Adenoma with Papillary Thyroid Carcinoma (유두상 갑상선암과 동반된 기능성 낭종성 부갑상선 선종 1예)

  • Chang, Woo-Jin;Jung, Hyun-Hee;Park, Sang-Hyen;Sohn, Se-Hoon;Yoon, Ji-Sung;Lee, Hyoung-Woo;Won, Kyu-Chang;Cho, In-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.139-145
    • /
    • 2010
  • Cystic parathyroid adenoma is one of rare causes of hyperparathyroidism, and tends to cause increased serum level of parathyroid hormone, alkaline phosphate and serum calcium level similar to when compared to those of solid adenoma. The possibility of a coincidental appearance of primary hyperparathyrodism and nonmedullary thyroid cancer is rare, and often neglected. A 40-year-old female presented with constipation and weight loss for 3 months. The serum calcium, phosphate and alkaline phosphate were 16.6 mg/dl, 2.2 mg/dl and 505 IU/L respectively and serum parathyroid hormone level was 1556.2 pg/mL. Neck US showed mixed nodules at both thyroid lobes, and PET-CT showed a right thyroid nodule without FDG uptake. The patient was diagnosed of primary hyperparathyroidism and underwent parathyroidectomy and a total thyroidectomy. Histopathologic results revealed parathyroid adenoma with cystic change (2 cm greater diameter) in the right lower parathyroid gland and coexistent papillary carcinoma of the right lobe of thyroid gland (infiltrating, 0.3 cm in greater diameter). She remained well and serum calcium, phosphate, parathyroid hormone level were normalized within 24 hours.

  • PDF

Evaluation of absorbed dose in monkey and mouse using 18F-FDG PET and CT density information

  • Kim, Wook;Lee, Yong Jin;Park, Yong Sung;Cho, Doo-Wan;Lee, Hong-Soo;Han, Su-Cheol;Kang, Joo Hyun;Woo, Sang-Keun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.18-24
    • /
    • 2017
  • Patient-specific image-based internal dosimetry involves using the patient's individual anatomy and spatial distribution of radioactivity over time to obtain an absorbed dose calculation. Individual absorbed dose was calculated by accumulated activity multiply S-value of each organs. The aim of this study was to calculate the S-values using Monte Carlo simulation in monkey and mouse and evaluation of absorbed dose in each organ. Self-irradiation S-value of monkey heart self-irradiation was 3.15E-03 mGy-g/MBq-s, lung self-irradiation was 8.94E-04 mGy-g/MBq-s and liver self-irradiation S-value was 2.23E-03 mGy-g/MBq-s. Mouse heart self-irradiation S-value was 1.95E-01 mGy-g/MBq-s, lung was 9.59E-02 mGy-g/MBq-s, and liver was 1.40E-03 mGy-g/MBq-s. The results of this study show that the calculation protocol of image based individual absorbed dose of each organ using Monte Carlo simulation. Therefore, this study may be applied to calculate human specific absorbed dose.

A Case of Recurrent Papillary Thyroid Carcinoma with Adrenal Metastasis (재발 유두 갑상선암의 부신전이 1예)

  • Kim, Chang-Woo;Yun, Ji-Sup;Lee, Yong-Sang;Nam, Kee-Hyun;Chung, Woong-Youn;Hong, Soon-Won;Park, Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.50-53
    • /
    • 2007
  • Adrenal metastasis from papillary thyroid carcinoma is extremely rare. We present herein a patient with adrenal metastases from recurrent papillary carcinoma of the thyroid. A 54 year-old woman had received a total thyroidectomy and postoperative radioactive iodine therapy for locally advanced papillary thyroid carcinoma. One year after initial surgery, distant metastases to multiple organs including right cervical lymph nodes, left upper lung, left 2nd and 3rd ribs, 2nd thoracic vertebra and left adrenal gland were found by 18-FDG-PET-CT whole body scan. She underwent right modified neck dissection, partial resection of left 2nd and 3rd ribs, posterior arch of 2nd thoracic vertebra, left upper lobectomy of lung, and left adrenalectomy. On histologic examination, metastases to the left adrenal gland and cervical lymph nodes were papillary thyroid carcinomas, while other metastatic sites turned out to be anaplastic thyroid carcinomas. Despite aggressive surgery and postoperative adjuvant therapy, her general clinical conditions were getting worse day by day due to regrowing of the anaplastic thyroid carcinomas. To our knowledge, this is the first case reported in Korea.

Experience of Reconstruction of an Extensive Chest Wall Defect with Extended External Oblique Musculocutaneous Flap (거대 흉벽 결손에 대한 확장 외복사근 근피판을 이용한 흉벽재건 치험례)

  • Kim, Dae-Hee;Kim, Chung-Hun;Song, Seung-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.277-280
    • /
    • 2010
  • Purpose: The resection of locally advanced or recurred breast cancers frequently result in large chest wall defects and it leads to a great challenges to cover. Generally simple skin grafts are not a practical option for patients because of their poor cosmetic appearance and prognosis. The latissimus dorsi and rectus abdominis musculocutaneous flap have traditionally been recommended for closure of these large defects. Though the cosmetic result of reconstruction using these flaps is often excellent, but has significant drawbacks. Therefore, we thought that chest wall reconstruction using the external oblique musculocutaneous flap can be an alternative method for extensive chest wall defect related to large, locally advanced breast carcinoma. Methods & Results: We present a case of a 50-year-old Korean female, refered to our department with a left breast tumor for 10 months. CT demonstrate a large tumor on the left anterior chest wall and multiple nodules of varying size in the cervical areas and liver. FDG-PET showed areas of hot uptake throughout the left chest wall, mediastinum and liver. Biopsy was consistent with invasive ductal carcinoma (Grade III). The initial tumor was considered inoperable, so a series of chemotherapy was initiated. Though the size of the breast mass was slightly decreased, the patient continued to suffer from purulent discharge, unpleasant odor and contact bleeding of the mass, the salvage mastectomy was performed. Conclusion: We could reconstruct $23{\times}16\;cm$ sized large chest wall defect, resulting from the resection of a locally advanced breast carcinoma, using an external oblique musculocutaneous flap successfully. Immediate postoperatively checked flap was healthy. Overall result was good without any significant complications and discharged 3 weeks after operation.

A Case Report of Salivary Duct Carcinoma (이하선에 생긴 침샘관암의 치험례)

  • Park, Sung Wook;Kang, Sang Yoon;Kim, Tae Hun;Kim, Chung Hun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.607-610
    • /
    • 2008
  • Purpose: Salivary duct carcinoma(SDC) is uncommon but high grade adenocarcinoma arising in the ductal epithelium of salivary glands. SDC is characterized by distinctive clinical and pathologic features. The most important histologic aspect of this neoplasm is its resemblance to ductal carcinoma of the breast. Clinically SDC is defined by cervical lymph node involvement and distant metastasis with a high rate of recurrence and mortality. We described some of the clinical and pathological features of SDC and the management using case report for our patient. Methods: We present a case of a 40-year-old male with 2-year history of a swelling arising in his left preauricular region. There was a single painless, firm and solid $2{\times}1.5cm$ mass in the left parotid area. Facial nerve function was intact and no cervical lymph node were palpable. In August 2005, we found out $1.7{\times}1.8cm$ sized cystic, nodular lesions that were located in the superficial lobe of left parotid gland through Computed tomography. And then superficial parotidectomy and postoperative radiation therapy were performed in Jan 2007. Results: Pathologically, the specimen were consisted of homogeneous, chondoid to myxoid type of tissues. It was yellow mass that has multiloculated cystic lesions. In postoperative PET(Positiron emission tomography) CT, there was no evidence of uptaking FDG(Fluorodeoxyglucose) into the deep layers of parotid gland and distant metastasis were not seen. Conclusion: Salivary duct carcinoma(SDC) is a rare but high grade adenocarcinoma related to pleomorphic adenocarcinoma. The prognosis of SDC can be different according to the type of tumor such as mucoepidermoid adenocarcinoma, adenoid duct carcinoma and acinar cell carcinoma. So we need to study more carefully for accurate diagnosis in early stage of diagnosis. Although radiotherapy has not yet proven to be a significant factor in overall survival, the combination of parotidectomy and postoperative radiation therapy can lead to more favorable results in treating of SDC.

Radiation Exposure of Hands and Feet from $^{18}F$-FDG in Radio-technologists (방사선 작업 종사자의 작업화 및 작업복의 방사선 오염 분석)

  • Lee, Seung-Jae;Jeong, Seok;Seo, Soo-Hyun;Park, Yong-Sung;Park, Hoon-Hee;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.94-98
    • /
    • 2011
  • Purpose: The radiation exposure from radioisotope at the hands and foots of radiation workers who works in PET/CT part at the department of nuclear medicine was investigated in this study. Materials and Methods: From 4th August 2010 to 14th January 2011, 6 radio-technologists' radiation on hands and feet were measured. All radio-technologist have been examined around 8; morning, 12; afternoon, and 16 o'clock; evening, respectively. SPSS version 17 was used for statistical analysis. Results: The statistical significances were calculated in several ways. The radiation from both hands and feet in the Morning was lower than Afternoon and Evening. In some cases, the detected radiation showed extremely high values in data. In order to find the effect of the ${\gamma}$-ray on the hand, the estimated doses were presumably calculated, however, the exposure dose on feet were unmeasured. Conclusion: Even if the radiation exposure from the radioisotope at the hands and feet were under the limitations, it is definitely needs to prevent the radiation-contamination. Therefore, the radio-technologists need to have a proper radiation-dealing-procedure of their own, and must try to prevent a radiation exposure by themselves.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

The Characteristics of Bronchioloalveolar Carcinoma Presenting with Solitary Pulmonary Nodule (고립성 폐결절로 나타난 기관지폐포암의 임상적 고찰)

  • Kim, Ho-Cheol;Cheon, Eun-Mee;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.;Han, Yong-Chol;Lee, Kyoung-Soo;Han, Jung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.280-289
    • /
    • 1997
  • Background : Bronchioloalveolar carcinoma (BAC) has been reported to diveres spectrum of chinical presentations and radiologic patterns. The three representative radiologic patterns are followings ; 1) a solitary nodule or mass, 2) a localized consolidation, and 3) multicentric or diffuse disease. While, the localized consolidation and solitary nodular patterns has favorable prognosis, the multicentric of diffuse pattern has worse prognosis regardless of treatment. BAC presenting as a solitary pulmonary nodule is often misdiagnosed as other benign disease such as tuberculoma. Therefore it is very important to make proper diagnosis of BAC with solitary nodular pattern, since this pattern of BAC is usually curable with a surgical resection. Methods : We reviewed the clinical and radiologic features of patients with pathologically-proven BAC with solitary nodular pattern from January 1995 to September 1996 at Samsung Medical Center. Results : Total 11 patients were identified. 6 were men and 5 were women. Age ranged from 37 to 69. Median age was 60. Most patients with BAC with solitary nodular pattern were asymptomatic and were detected by incidental radiologic abnormality. The chest radiograph showed poorly defined opacity or nodule and computed tomography showed consolidation, ground glass appearance, internal bubble-like lucencies, air bronchogram, open bronchus sign, spiculated margin or pleural tag in most patients. The initial diagnosis on chest X-ray were pulmonary tuberculosis in 4 patients, benign nodule in 2 patients and malignant nodule in 5 patients. The FDG-positron emission tomogram was performed in eight patients. The FDG-PET revealed suggestive findings of malignancy in only 3 patients. The pathologic diagnosis was obtained by transbronchial lung biopsy in 1 patient, by CT guided percutaneous needle aspiration in 2 patients, and by lung biopsy via video-assited thoracocopy in 8 patients. Lobectomy was performed in all patients and postoperative pathologic staging were $T_1N_0N_0$ in 8 patients and $T_2N_0M_0$ in 3 patients. Conclusion : Patients of BAC presenting with solitary nodular pattern were most often asymptomatic and incidentally detected by radiologic abnormality. The chest X-ray showed poorly defined nodule or opacity and these findings were often regarded as benign lesion. If poorly nodule or opacity does not disappear on follow up chest X-ray, computed tomography should be performed. If consolidation, ground glass appearance, open bronchus sign, air bronchogram, internal bubble like lucency, pleural tag or spiculated margin are found on computed tomography, further diagnostic procedures, including open thoracotomy, should be performed to exclude the possiblity of BAC with solitary nodular pattern.

  • PDF

Burnt-out Metastatic Prostate Cancer

  • Shin, Dong Suk;Koo, Dong Hoe;Yoo, Suhyeon;Ju, Deok Yun;Jang, Cheol Min;Joo, Kwan Joong;Shin, Hyun Chul;Chae, Seoung Wan
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.116-119
    • /
    • 2013
  • A burnt-out prostate cancer tumor is a very rare clinical entity. The term 'burnt-out' refers to a primary tumor that has spontaneously and nearly completely regressed without treatment. Since metastasis of prostate cancer is usually encountered in the presence of advanced disease, distant metastasis with an undetectable primary tumor is very rare. We report herein a case of a burnt-out prostate cancer tumor that metastasized to the thoracic (T) spine and caused cord compression. A 66-year-old man visited the Emergency Department due to weakness of both legs for the past two days. His blood and urine tests were normal at the time. His spine magnetic resonance imaging (MRI) scans looked like bone metastasis that involved the T-7 vertebral body and a posterior element, and caused spinal cord compression. Other images, including from the brain MRI, neck/chest/abdomino-pelvic computed tomography (CT) scan and 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) and endoscopy, revealed no lesions that suggested malignancy. After total corpectomy T-7 and screw fixation/fusion at T5 to T10, the pathology report revealed a metastatic carcinoma that was strongly positive for prostate-specific antigen (PSA). The serum PSA value was 1.5 ng/mL. The transrectal 12-core prostate biopsy and ultrasonography showed no definitive hypoechoic lesion, but one specimen had slight (only 1%) adenocarcinoma with a Gleason score of 6 (3+3). The final diagnosis was burned-out prostate cancer with an initial normal PSA value. Although metastatic disease with an unknown primary origin was confirmed, a more aggressive approach in seeking the primary origin could provide a more specific treatment strategy and greater clinical benefit to patients.