• 제목/요약/키워드: FC40

검색결과 88건 처리시간 0.027초

수평 다채널 관에서의 유동 비등 열전달 특성에 관한 연구 (Study on Characteristics of Flow Boiling Heat Transfer in Multi channels)

  • 최용석;임태우
    • 수산해양교육연구
    • /
    • 제27권5호
    • /
    • pp.1310-1317
    • /
    • 2015
  • Two-phase flow boiling heat transfer in micro-channels was experimently investigated. The test section consisted of 15 rectangular micro-channels with a depth of 0.45mm, width of 0.20mm. The experiments were performed for heat fluxes ranging from 5.6 to 46.1kW/m2 and mass fluxes from 150 to 450kg/m2s using FC-72 as the working fluid. According to the results, at the low heat flux region, heat transfer coefficient strongly depends on the heat flux, while heat transfer coefficient at the high heat flux region was independent on the heat flux. Four correlations were used to predict the heat transfer coefficient. The measured heat transfer coefficient was compared with four correlations. It was found that Kaew-On and Wongwises's correlation well predicted the measured data, within the MAE of 40.3%.

기능성 변비를 가진 여대생의 식습관, 생활 스트레스 및 건강관련 삶의 질의 관계 (Correlation among Dietary Habits Score, Life Stress Score and Health-Related Quality of Life (HRQL) Score for Female College Students with Functional Constipation)

  • 유정순;박지연;장경자
    • Journal of Nutrition and Health
    • /
    • 제43권6호
    • /
    • pp.620-627
    • /
    • 2010
  • 본 연구는 기능성 변비를 가진 여대생들의 식습관, 생활 스트레스, 건강관련 삶의 질을 파악한 후 이들의 관계를 살펴보고자 인천지역 대학교에서 건강관련 교양 강의를 듣는 여대생을 대상 (265명)으로 설문조사와 신체계측을 실시하였다. 기능성 변비의 기준은 로마기준 II를 이용하였으며, 정상군은 179명 (67.5%), 기능성변비군은 86명 (32.5%) 이었다. 조사대상자의 평균 연령은 20.8세, 자택에서 거주하는 비율은 69.8%로 가장 많았으며 20~40만원을 받고 있는 학생이 전체의 61.1%이었고 변비 유무에 따른 유의적인 차이는 없었다. 식습관 점수를 살펴보면 식품섭취의 다양성에 관한 항목은 변비군이 정상군에 비해 유의적으로 낮았고 나머지 항목들은 유의적이지는 않지만 낮은 경향을 보였다. 변비군과 정상군 모두 채소류 섭취와 유제품 섭취에 관한 점수가 가장 낮았다. 스트레스 점수는 교수 문제, 학업 문제, 경제 문제, 가치관 문제와 총 합계 점수에서 변비군이 정상군에 비해 유의적으로 높았다. 건강관련 삶의 질을 SF-36을 통해 살펴본 결과 변비군의 평균은 70.4점, 정상군의 평균은 74.3점으로 변비군의 삶의 질이 정상군보다 낮음을 알 수 있었고, 8개의 항목 중 신체적 역할 제한 영역, 감정적 역할 제한 영역 또한 변비군이 정상군에 비해 유의적으로 낮은 점수를 보였다. 기능성 변비를 가지고 있는 여학생들의 식습관 점수, 생활 스트레스 점수, 건강관련 삶의 질 점수의 상관관계를 살펴본 결과 생활 스트레스 점수는 식습관 점수와 유의한 부적 상관관계 (r = -0.221, p < 0.05)를 보여 생활 스트레스가 높을수록 식습관 점수가 낮았고, 스트레스와 건강관련 삶의 질 간에도 부적 상관관계 (r = -0.539, p < 0.001)를 보여 생활 스트레스가 높을수록 건강관련 삶의 질이 낮아짐을 알 수 있었다. 본 연구의 결과들로 볼 때 기능성 변비를 가진 경우 식품을 다양하게 섭취하도록 교육하고, 스트레스를 낮출 수 있도록 스트레스 관리에 대한 중재가 필요하다고 판단된다.

말기 심부전증 환자에 대한 심장이식술의 조기 성적 (Early Results of the Heart Transplantation for End Stage Heart Failure)

  • 노준량;원태희
    • Journal of Chest Surgery
    • /
    • 제30권9호
    • /
    • pp.876-884
    • /
    • 1997
  • 서울대학교병원 흉부외과에서는 1994년 3월부터 1996년 5월까지 14명의 환자에 있어서 심장이식술을 시행 하였다. 남자가 9명 여자가 5명이었으며 평균나이는 40.8 $\pm$ 12.4세 이었다. 수술전 모든 환자들은 UiID Fc III 또는 IV이었으며 술전 진단은 확장성 심근병증이 11명, 제한성 심근병증이 3명이었다. 장기 공여자의 평균연령은 24.9 $\pm$ 10.2세 이었으며 뇌사의 원인으로는 교통사고에 의한 뇌손상이 8명으로 가장 많았으며 거미막하 출혈이 2명, 이 물질에 의한 기도폐쇄, 추락사고, 뇌종양, 익사사고 등이 각각 1명이 었다. 수혜자와 공여자의 혈액형은 11명에 있어서는 일치되었고 2명에 있어서는 적합하였으나 1명의 환자에 있 어서는 부적합하였다. 11명의 환자에 있어서는 양대정맥을 직접 문합하는 방법을 사용하였으며 3명의 환자에 있어서는 우심방을 연결하는 방법을 사용하였으며 평균 이식심장 허혈시간은 157.8 $\pm$ 43.8분(94-220분) 이었다. 2명이 사망하 여 병원 사망률은 14.3%이었다. 사망원인은 우심실부전, 사이클로스포린 유발성 용혈성요독증후군, 거부반응 으로 인한 다발성 장기부전과 대동맥 문합부위 가성동맥류의 파열로 의심되는 酉\ulcorner銖汰潔駭\ulcorner 평균추적기간은 16.2 $\pm$ 9.0개월(3-28개월) 이었으며 만기사망은 1례 있었다. (8.3%) 마지막 추적당시 급성 거부반응으로 치료를 받고 있는 1명을 제외한 모든 환자들은 UnD Fc I이었다. 병원사망을 포함한 1개월 및 6개월, 2년 생존율은 각각 n.9 $\pm$ 6.9%, 85.7 $\pm$ 9.4% , 77.1 $\pm$ 11.7% 이었다. 결론적으로 심장이식술은 말기 심부전환자의 이상적인 치료법이며 앞으로 장기적인 추적검사가 필요하리라 생각된다.

  • PDF

농업적 용수재이용 수질기준을 고려한 적정 하수재처리에 관한 연구 (Guidelines and Optimum Treatment for Agriculture Reuse of Reclaimed Water)

  • 정광욱;전지홍;함종화;윤춘경
    • 생태와환경
    • /
    • 제36권3호통권104호
    • /
    • pp.356-368
    • /
    • 2003
  • 본 연구에서는 국제적으로 사용하고 있는 농업용수 재이용 수질기준을 검토하고 우리나라 하수처리 방류수의 재이용 가능성에 대하여 고찰하였으며, 재이용수로이용하기 위해 필요한 처리대안에 실험 ${\cdot}$ 연구한 결과이다. Biofilter 유출수를 17, 25, 40W의 3가지 램프로 UV소독한 결과 40W 램프에서는 모든 경우에 100%소독되었으며, 25 W와 17 W에서는 전반적으로 97%이상 소독효율을 나타내었으며, 적절하게 설계된 UV소독을 거친 하수처리장 유출수는 USEPA와 WHO의 가장 엄격한 수질기준을 충분히 만족시켜서 보건 ${\cdot}$ 위생적인 문제를 일으키지 않을 것으로 판단된다. 간헐 분사방식의 완속모래여과 처리후 미생물의 처리효율은 TC, FC, E. coli 모두 평균 95% 이상 높은 처리 효율을 나타내었으며, 완속모래여과 후의 평균 농도는 각각 330, 207, 154 MPN/100 mL이었고 탁도와 SS는 모두 약 50%의 처리효율을 나타내었는데, 이는 WHO의 수질기준을 충분히 만족시켰으며, USEPA의 수질기준인 200FC/100mL의 경우에도 적절한 관리가 이루어 질 경우 만족시킬 수 있을 것으로 판단된다. 탁도는 평균 0.8NTU로써 먹는물 수질기준인 INTU수준이었고, SS의 경우에도 50% 이상의 처리효율을 나타내어 USEPA의 가장 엄격한 수질기준을 충분히 만족하였으며, 영양물질의 제거에도 기여를 하기 때문에 수계의 오염부하를 줄이는 측면에서도 유리할 것으로 생각된다. 연못시스템을 거치면서 TC, FC, E. coli 모두 85%정도 제거되어 평균미생물농도가 1,000MPN/100 m1 이하이었다. 우리나라의 수질기준으로 WHO 수질기준이 논농사에 적용될 경우 소독이나 여과처리 없이도 재이용할 수 있을 것이라 판단되나, USEPA의 수질기준이 적용될 경우에는 연못시스템만으로도 부족하여 추가적인 처리가 필요할 것으로 생각된다. 과거 US EPA의 위험을 완전히 배제한 수질기준을 여러 국가에서 받아들여 사용하고 있으나, WHO에서는 이수질기준이 경제 ${\cdot}$ 사회적으로 불합리한 기준이라 판단하고 보다 완화된 수질기준을 제시하였다. 우리나라에서도 수질기준을 결정할 때 논농사라는 특수한 실정에 맞는 수질 기준을 정해 경제적이고 실용적인 처리방법을 선정하는 것이 중요하다고 할 수 있다. 벼의 경우는 껍질과 추가적인 처리 후 섭취하는 작물이기 때문에 엄격한 수질기준이 필요하지 않을 수 있으나, 장기간 담수상태를 유지함으로써 농민을 포함한 공중보건에 위해성을 줄 가능성이 크므로 세균성미생물 등에 대한 신중한 결정이 필요하다.

위성 토양수분 데이터 및 COSMIC-ray 데이터 보정/검증을 위한 성균관대학교 내 FDR 센서 토양수분 측정 연구(SM-FC) 및 데이터 분석 (Construction and estimation of soil moisture site with FDR and COSMIC-ray (SM-FC) sensors for calibration/validation of satellite-based and COSMIC-ray soil moisture products in Sungkyunkwan university, South Korea)

  • 김형록;선우우연;김성균;최민하
    • 한국수자원학회논문집
    • /
    • 제49권2호
    • /
    • pp.133-144
    • /
    • 2016
  • 본 연구에서는 수원 성균관대학교 내 Frequency Domain Reflectometry (FDR) 토양수분 측정 장비 및 COSMIC-ray 중성자 측정 장비를 통한 토양수분 지점 관측 사이트를 확립하였다. 또한 양질의 토양수분 데이터 확보를 위해 연구지역 내 토질실험, 토질별 FDR 토양수분 데이터 및 COSMIC-ray 중성자 개수의 시계열 분석, 관측한 토양수분 데이터와 위성 기반 토양수분 데이터와의 비교분석을 실시하였다. 2014년도부터 6개 지점에서 표층으로부터 5 cm에서 40 cm까지 총 24개의 FDR 센서를 5~10 cm 깊이별로 설치하여 토양수분 데이터를 측정하였다. 해당 지점들의 토질 분석결과, Sand에서 Loamy Sand까지의 다양한 토질이 불균질한 층을 이루어 분포되어 있는 것으로 판단되었다. 측정된 토양수분 데이터는 강우 데이터와 높은 상관성을 보이며, 위성 산출 토양수분 데이터와의 비교에서도 상대적으로 높은 상관관계와 낮은 평균제곱근편차(Root mean square deviation, RMSD)값을 보여주었다. 2014년도 설치 지역 토양수분 데이터의 신뢰도가 확보됨에 따라 2015년도에는 10개의 FDR 토양수분 측정 장비 및 COSMIC-ray 중성자 측정 장비가 추가로 설치되어 성균관대학교의 Soil Moisture site with FDR and COSMIC-ray(SM-FC) 연구지역이 구축되었다. SM-FC에 설치된 COSMIC-ray 중성자 측정 장비의 최초 검증을 위해 2015년 8~11월의 COSMIC-ray 중성자 데이터 및 FDR 토양수분 데이터가 활용되었다. 중성자기반 토양수분 값과 전체 지점 FDR 토양수분 평균값을 비교한 결과 매우 높은 상관관계를 볼 수 있었다 (상관계수 0.95). 이러한 연구를 통해 성균관대학교 SM-FC는 향후 한반도 지역 위성 및 모델 토양수분 데이터를 검증하는 대표 연구지역이 될 것으로 기대된다.

Nutrition Practice to Alleviate the Adverse Effects of Stress on Laying Performance, Metabolic Profile and Egg Quality in Peak Producing Hens: II. The Probiotic Supplementation

  • Hayirli, Armagan;Esenbuga, N.;Macit, M.;Yoruk, M.A.;Yildiz, A.;Karaca, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권12호
    • /
    • pp.1752-1760
    • /
    • 2005
  • In this experiment, the effects of cage density (CD) and probiotic supplementation (PS) on laying performance, metabolic profile, and egg quality in peak-producing hens were evaluated. After blocking according to the cage location, Lohman layers (n = 180, 46 wks of age) were allocated randomly to two levels of CD (540 vs. 360 $cm^2$/hen) and three levels of PS (0, 0.15, and 0.30%). Probiotic contained Enterococcus faecium culture (10${\times}$10$^9$ cfu/g). Egg production (EP) and feed consumption (FC) were measured daily; egg weight (EW) was measured bi-weekly; BW was measured before and after the experiment; and blood samples were obtained at the end of the experiment. The data were analyzed using two-way ANOVA. Increasing CD decreased FC (125.0 vs. 120.8 g/d, p<0.0001) and FCR (1.93 vs. 1.87, p<0.0001) and did not alter EP, EW, and BW. Increasing level of PS linearly decreased FC (p<0.02) and FCR (p<0.006). Averages were 123.9, 123.2, and 121.6 g/d for FC and 1.91, 1.92, and 1.86 for FCR in hens supplemented with 0, 0.15, and 0.30% probiotic, respectively. Hens placed in high-density cages had greater serum corticosterone concentration than hens placed in normal-density cages (12.8 vs. 11.3 $\mu$g/dL, p<0.04); CD did not affect concentrations of other metabolites. Increasing level of PS linearly increased serum glucose, albumin, and creatine concentrations and quadratically increased total protein, globulin, Ca, and P concentrations. Average concentrations (mg/dL) were 260, 297, and 305 for glucose; 6.28, 8.09, and 7.58 for total protein; 1.98, 2.48, and 2.38 for albumin; 4.30, 5.62, and 5.19 for globulin; 0.40, 0.52, and 0.54 for creatine; 16.0, 16.5, and 16.3 for Ca; and 6.27, 8.14, and 7.17 for P in hens supplemented with 0, 0.15, and 0.30% probiotic, respectively. There was no effect of CD on egg quality. Increasing level of PS linearly improved yolk color (YC) and quadratically increased albumen index (AI) and Haugh unit (HU). The mean values were 9.67, 9.75, and 10.58 for YC; 8.94, 6.93, and 8.72% for AI; and 85.6, 74.9, and 82.9 for HU for hens supplemented with 0, 0.15, and 0.30% probiotic, respectively. There was also CD by PS effect on FC, EP, and serum glucose, total protein, albumin, globulin, creatine, Ca and P concentrations. In conclusion, increased CD partially depressed laying performance and caused stress. Probiotic supplementation improved laying performance and metabolic profile. It also partially alleviated the adverse effects of stress resulting from increased caging density.

수성이상계에서 Pluronic F-68과 산소전달물질이 참당귀 현탁세포 증식에 미치는 영향 (Effects of Pluronic F-68 and Oxygen Vectors on the Cell Growth of Angelica gigas Nakai in Aqueous Two-Phase System)

  • 전수환;이경훈;권준영;류현남;김동일
    • KSBB Journal
    • /
    • 제22권4호
    • /
    • pp.207-212
    • /
    • 2007
  • 본 연구에서는 수성이상계에서 Pluronic F-68과 산소전달물질을 적용하여, 물질전달과 산소전달을 증가시켜 당귀세포의 증식을 향상시켰다. 특히 산소전달물질인 n-hexadecane이 Pluronic F-68보다 수성이상계에서의 당귀 세포증식에 더 긍정적임을 확인하였다. 따라서 Pluronic F-68과 적절한 산소 전달물질의 첨가는 수성이상계 뿐만 아니라 대량배양을 위한 고농도배양 등에 효과적으로 적용가능하리라 사료된다.

알레르기성 비염에서 황련-감초 하태독법의 IL-4활성 조절을 통한 항염증효과 (Anti-inflammatory effects of Hataedock with Coptidis Rhizoma and Glycyrrhiza Uralensis on Allergic Rhinitis through Regulating IL-4 Activation)

  • 정아람
    • 동의생리병리학회지
    • /
    • 제33권2호
    • /
    • pp.116-122
    • /
    • 2019
  • The aim of this study is to evaluate the anti-inflammatory effect of Hataedock treatment using Coptidis Rhizome and Glycyrrhiza Uralensis (CG) mixed extract in allergic rhinitis induced NC/Nga mice. We divided NC/Nga mice into 3 groups as follows; allergic rhinitis-induced group after CG Hataedock treatment (CGT, n=10), no treatment group (Ctrl), allergic rhinitis elicited group (ARE). To induce allergic rhinitis, NC/Nga mice of 3 weeks age were sensitized on 7, 8 and 9week by Ovalbumin (OVA) antigen in intranasal space. Hataedock using CG extract was administered on week 3 in allergic rhinitis-induced group (CGT) after Hataedock treatment. To identify distribution of Interlukin (IL)-4, Cluster of differentiation 40 (CD40), high-affinity IgE receptor ($Fc{\varepsilon}RI$), substance P, Matrix metallopeptidase 9 (MMP-9), Nuclear $factor-{\kappa}B$ ($NF-{\kappa}B$) p65, Inducible nitric oxide synthase (iNOS) and Cycloxygenase-2 (COX-2), we used histological examination. CGT significantly inhibited IL-4 and CD40 response compared with ARE. The reduction of Th2 cytokine expression decreased inflammatory mediators such as $Fc{\varepsilon}RI$, substance P, MMP-9, $NF-{\kappa}B$ p65, iNOS and COX-2. Such immunological improvement induced reduction of respiratory epithelial damage and mucin secretion in goblet cell. These results indicate that Hataedock treatment suppresses allergic rhinitis through modulating of Th2 responses and diminishing various inflammatory mediators in nasal mucosal tissue. It might have potential applications for prevention and treatment of allergic rhinitis.

전력변환 반도체 냉각용 PFC(FC-72) 밀폐형 2상 열사이폰의 열전달 한계에 관한 연구 (A Study on the Heat Transport Limitations of a PFC(FC-72) Two-Phase Closed Thermosyphon for Cooling Power Semiconductors)

  • 박용주;홍성은;김철주
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.725-733
    • /
    • 2002
  • In this study, the heat transport limitations of a two-phase closed thermosyphon were investigated. For the test, a two-phase closed thermosyphon ($L_t/: 600 mm,\;L_e:105mm,\;L_a:75mm,\;L_c:420mm,\;D_o:22.2mm,$ container: copper (inner grooved surface), working fluid: PFC ($C_6F_14$) was fabricated with a reservoir that can change the fill charge ratio. The following was imposed as the factors on the heat transport limitations of a two-phase closed thermosyphon. 1) Fill charge ratio of the working fluid. 2) Tilt angle of the longitudinal axis. From tile experimental data, some results were obtained as follows. When the fill charge ratio was relatively small ($\psi$20%), the heat transport limitation occurred about 100W by dry-out limitation. However over 40%, it shelved nearly constant value (500 W) by flooding limitation. The heat transport limitation according to the tilt angle increased smoothly until the tilt angle was $60^{\circ}$,/TEX>, after then decreased slowly.

An Analytic Study on Laminar Film Condensation along the Interior Surface of a Cave-Shaped Cavity of a Flat Plate Heat Pipe

  • Lee, Jin-Sung;Kim, Tae-Gyu;Park, Tae-Sang;Kim, Choong-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.966-974
    • /
    • 2002
  • An analytic approach has been employed to study condensate film thickness distribution inside cave-shaped cavity of a flat plate heat pipe. The results indicate that the condensate film thickness largely depends on mass flow rate and local velocity of condensate. The increasing rate of condensate film for circular region reveals about 50% higher value than that of vertical region. The physical properties of working fluid affect significantly the condensate film thickness, such as the condensate film thickness for the case of FC-40 are 5 times larger than that of water. In comparison with condensation on a vertical wall, the average heat transfer coefficient in the cave-shaped cavity presented 10∼15% lower values due to the fact that the average film thickness formed inside the cave-shaped cavity was larger than that of the vertical wall with an equivalent flow length. A correlation formula which is based on the condensate film analysis for the cave-shaped cavity to predict average heat transfer coefficient is presented. Also, the critical minimum fill charge ratio of working fluid based on condensate film analysis has been predicted, and the minimum fill charge ratios for FC-40 and water are about Ψ$\_$crit/=3∼7%, Ψ$\_$crit/=0.5∼1.3% respectively, in the range of heat flux q"=5∼90kW/㎡.