• Title/Summary/Keyword: FBG sensitivity

Search Result 62, Processing Time 0.026 seconds

Characteristics of a Solder-Clad FBG Temperature Sensor (땜납이 용융 부착된 FBG 온도 센서의 특성)

  • Pyoung, Jae-Hyub;Lee, Sang-Bae;Shin, Jong-Dug
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.10
    • /
    • pp.45-50
    • /
    • 1999
  • We report a solder-clad fiber Bragg grating(FBG) temperature sensor in order to obtain better Bragg wavelength sensitivity to temperature than a bare FBG sensor. The solder-clad FBG sensor shows a wavelength sensitivity improvement by a factor of four compared to the case of a bare FBG sensor at temperatures below $110^{\circ}C$. However, it has a sensitivity of 0.01 $nm/^{\circ}C$ at temperatures over $110^{\circ}C$, which is identical to that of a bare FBG sensor. Bragg wavelength of the sensor shows a blue-shift below $110^{\circ}C$ because the sensor is fabricated above melting temperature of solder. The thermal stress at the FBG-solder interface has been relieved by annealing, which results in a stable operation.

  • PDF

A PDMS-Coated Optical Fiber Bragg Grating Sensor for Enhancing Temperature Sensitivity

  • Park, Chang-Sub;Joo, Kyung-Il;Kang, Shin-Won;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.329-334
    • /
    • 2011
  • We proposed a poly-dimethylsiloxane (PDMS)-coated fiber Bragg grating (FBG) temperature sensor for enhancing temperature sensitivity. By embedding the bare FBG in a temperature-sensitive elastomeric polymer, the temperature sensitivity of the proposed structure could be effectively improved by 4.2 times higher than those of the conventional bare-type FBG sensors due to the high thermal expansion coefficient of the PDMS. We analyzed the temperature-sensitivity enhancement effect with the increased Bragg wavelength shift in our structure and dependence on the temperature sensitivity with respect to the cross-section area of the PDMS.

FBG Sensor Probes with Silver Epoxy for Tracing the Maximum Strain of Structures

  • Im, Jooeun;Kim, Mihyun;Choi, Ki-Sun;Hwang, Tae-Kyung;Kwon, Il-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.459-464
    • /
    • 2013
  • Structures can be evaluated their health status by allowable loading criteria. These criteria can be determined by the maximum strain. Therefore, in order to detect this maximum strain of structures, fiber optic Bragg grating(FBG) sensor probes are newly designed and fabricated to perform the memorizing detection even if the sensor system is on-and-off. The probe is constructed with an FBG optical fiber embedded in silver epoxy. When the load is applied and removed on the structure, the residual strain remains in the silver epoxy to memorize the maximum strain effect. In this study, a commercial Al-foil bonded FBG sensor probe was tested to investigate the detection feasibility at first. FBG sensor probes with silver epoxy were fabricated as three different sizes. The detection feasibility of maximum strain was studied by doing the tensile tests of CFRP specimens bonded with these FBG sensor probes. It was investigated the sensitivity coefficient defined as the maximum strain divided by the residual strain. The highest sensitivity was 0.078 of the thin probe having the thickness of 2 mm.

Research on Temperature Sensing Characteristics of Fiber Bragg Grating in Wide Temperature Range

  • Naikui Ren;Hongyang Li;Nan Huo;Shanlong Guo;Jinhong Li
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.162-169
    • /
    • 2024
  • This study investigates the temperature sensitivities of fiber Bragg grating (FBG) across a broad temperature spectrum ranging from -196 ℃ to 900 ℃. We developed the FBG temperature measurement system using a high-temperature tubular furnace and liquid nitrogen to supply consistent high and low temperatures, respectively. Our research showed that the FBG temperature sensitivity changed from 1.55 to 10.61 pm/℃ in the range from -196 ℃ to 25 ℃ when the FBG was packaged with a quartz capillary. In the 25-900 ℃ range, the sensitivity varied from 11.26 to 16.62 pm/℃. Contrary to traditional knowledge, the FBG temperature sensitivity was not constant. This inconsistency primarily stems from the nonlinear shifts in the thermo-optic coefficient and thermal expansion coefficient across this temperature spectrum. The theoretically predicted and experimentally determined temperature sensitivities of FBGs encased in quartz capillary were remarkably consistent. The greatest discrepancy, observed at 25 ℃, was approximately 1.3 pm/℃. Furthermore, it was observed that at 900 ℃, the FBG was rapidly thermally erased, exhibiting variable reflected intensity over time. This study focuses on the advancement of precise temperature measurement techniques in environments that experience wide temperature fluctuations, and has considerable potential application value.

A Study on the Tank Liquid-Level Monitoring Sensor Systems for Large Scaled Vessels (대형선박의 액체 탱크용 수위 모니터링 센서 시스템 연구)

  • Sohn, Kyung-Rak;Kim, Jin-Wook;Cho, Seok-Je;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.330-335
    • /
    • 2009
  • A fiber-optic liquid level sensor based on bending cantilever beam has been proposed. A fiber Bragg grating(FBG) embedded in the cantilever beam is used to sensing elements. The basic concept is elongation and constriction of the FBG corresponding to the liquid level variation. The best FBG position on the cantilever for obtaining the high sensitivity was 4 cm from the fixing point. When the liquid level moves up and down vertically, the Bragg wavelength is linearly shifted. But, the wavelength sensitivity of the FBG installed on the upper side of cantilever was four times better than that of the FBG equipped in the lateral side due to the difference of unit strain applied to the FBG. Intensity demodulation using the low-cost edge filter is used to interrogate the Bragg wavelength through converting the wavelength signals into the optical intensity ones. Experiment results show that the electrical output is exponentially proportional to the liquid level. But, it should be overcome for applying to the ships.

A Study on the Accelerometer for the Acceleration and Inclination Estimation of Structures using Double-FBG Optical Sensors (이중 FBG 광섬유센서를 이용한 구조물 가속도 및 기울기 측정 장치에 관한 연구)

  • Lee, Geum-Suk;Ahn, Soo-Hong;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.1
    • /
    • pp.85-94
    • /
    • 2016
  • In this study, an acceleration sensor that has optical fibers to measure the inclination and acceleration of a structure through contradictory changes in two-component FBG sensors was examined. The proposed method was to ensure precise measurement through the unification of the deformation rate sensor and the angular displacement sensor. A high sensitivity three-axis accelerometer was designed and prepared using this method. To verify the accuracy of the accelerometer, the change in wavelength according to temperature and tension was tested. Then, the change in wavelength of the prepared accelerometer according to the sensor angle, and that of the sensor according to the change in ambient temperature were measured. According to the test results on the FBG-based vibration sensor that was developed using a high-speed vibrator, the range in measurement was 0.7 g or more, wavelength sensitivity, 2150 pm/g or more, and the change in wavelength change, $9.5pm/^{\circ}C$.

A Walking Vibration Sensing System using a Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 보행 진동 측정 시스템에 관한 연구)

  • Kim, Jaeki;Yeom, Sanghun;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • In this paper, a walking vibration sensing system (WVS system) using a Fiber Bragg Grating sensor (FBG sensor) is proposed. The seismic part of the FBG sensor was redesigned for sensitivity enhancement. The external excitation was assumed to be the walking cycle of an adult male. The FBG seismic sensor was redesigned using CATIA and ABAQUS such that the sensor's first mode natural frequency is 3.5 Hz (which is a value near the external excitation frequency). Compared with existing walking vibration sensing systems, this newly created system improves sensitivity 15 times. It is also suitable for intrusion detection applications.

A Study on Frequency Characteristics of Impact Induced Damage Signals of Composite Laminates as the Incident Angle of an FBG sensor (복합재 충격손상신호의 FBG센서 입사각도에 따른 주파수분포 특성에 관한 연구)

  • Bang, Hyung-Jun;Song, Ji-Yong;Kim, Chun-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.235-239
    • /
    • 2005
  • In this research, we investigated the frequency characteristic of low-velocity impact induced damage signals on graphite/epoxy composite laminates using high-speed fiber Bragg grating(FBG) sensor system. Appling the FBG sensors to damage assessment, we need to study the response of FBG sensors as the damage signals of the different incident angles because FBG shows different directional sensitivity. In order to discriminate an impact induced damage signal from that of undamaged case, drop impacts with different energies were applied to the composite panel with different incident angle to the FBG sensor. Finally, detected impact signals were compared using frequency distributions of wavelet detail components in order to find distinctive signal characteristics of composites delamination.

  • PDF

Technical review of discrimination method between strain and temperature on the FBG sensor (FBG 센서의 온도와 변형률 동시 측정기법 기술 분석)

  • Yoon, Hyuk-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.574-583
    • /
    • 2008
  • FBG(Fiber Bragg grating)s have shown a great potential for sensing applications, and are easily embedded in materials with a negligible impact on the mechanical properties of the host. However, the use of FBG sensors is limited by their simultaneous dependence on strain and temperature, thus only one parameter can be determined from a single grating. This paper reviews various methods to discriminate between strain and temperature effects. To overcome this cross sensitivity using only embedded optical fibers, a number of techniques have been proposed, most of them relying on the deconvolution of two simultaneous measurements.

  • PDF

The Influence of Hydrogen Loading on Radiation Sensitivity of Fiber Bragg Gratings (광섬유 브래그 격자의 방사선 민감도에 대한 수소로딩의 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2461-2465
    • /
    • 2013
  • This paper investigates the influence of hydrogen loading process on the radiation sensitivity of fiber Bragg gratings (FBG). We made the FBG inscribed in the same commercial Ge-doped fiber with different hydrogen loading periods. We measured the Bragg wavelength shift (BWS) of the FBG exposed to gamma-radiation up to a dose of 18 kGy, and evaluated the change of full width at half maximum (FWHM) and the FBG temperature sensitivity coefficient after irradiation. Varying hydrogen loading parameter led to BWS differences up to nearly a factor of two.