• Title/Summary/Keyword: FBG,

Search Result 489, Processing Time 0.034 seconds

Mean Fasting Blood Glucose Level and An Estimated Prevalence of Diabetes Mellitus Among A Representative Adult Korean Population (우리나라 성인 인구의 평균 공복혈당치와 당뇨병의 추정 유병률)

  • Kim, J.S.;Kim, Y.J.;Park, S.I.;Hong, Y.P.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.311-320
    • /
    • 1993
  • This study was carried out along with the 1990 6th National Tuberculosis Prevalence Survey in order to estimate the prevalence rate of diabetes mellitus among a representative adult Korean population. Fasting blood glucose was measured by diastix (Ames) using glucometer II for seventy seven percent of the population (30 year old or above) residing in 190 enumeration districts randomly sampled from 146,944 general ED. The prevalence of diabetes mellitus of the population was estimated by projecting the ratio of ${\geq}200mg/dl\;PP_2$ of fasting blood sugar level below 120 mg/dl by sex to the study population. Fasting blood glucose and 2 hr. postprandial blood glucose were measured on about 3000 subsampled individuals, and diabetes mellitus was defined by the WHO criteria-FBG${\geq}120mg/dl\;or\;PP_2{\geq}200mg/dl$ when FBG is below 120mg/dl. The results obtained are as follows : 1. Estimated prevalence(age adjusted) of diabetes mellitus was 4.6% for male and 8.1% for female. The age adjusted mean FBG was $93.9{\pm}26.2mg/dl$ for male and $102.9{\pm}31.5mg/dl$ for female. 2. The prevalence increased as age advanced with peak in $60{\sim}69$ years old age group for both sexes. 3. The mean FBG and estimated prevalence rate of diabetes mellitus varied considerably among the populations of fifteen cities and provinces ; it vaired from $87.0{\pm}17.7\;to\;104.6{\pm}34.5mg/dl$ and 1.2% to 8.9% for males, and from $93.3{\pm}25.3\;to\;116.7{\pm}38.6mg/dl$ and 3.4% to 20.8% for females. 4. The mean FBG and prevalence rates were higher among the rural population than those residing in metropolitan areas. 5. The proportion of the people previously treated among the diabetics was estimated to be a little less than one fifth. 6. Factors strongly associated with FBG were age, sex, family history of D. M., BMI, area and educational level among eleven variables.

  • PDF

Estimation Method of Strain Distribution for Safety Monitoring of Multi-span Steel Beam Using FBG Sensor (FBG센서를 이용한 다경간 강재 보 구조물의 안전성 모니터링을 위한 변형률 분포 추정 기법)

  • Oh, Byung-Kwan;Lee, Ji-Hoon;Choi, Se-Woon;Park, Hyo-Seon;Kim, You-Sok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.138-149
    • /
    • 2014
  • This study proposes an estimation method of strain distribution for multi-span steel beam structure under unspecific loading conditions. The estimation method in this paper employs the curve fitting using the least square method from measured strain data, not analytical method. To verify the proposed estimation method, a static loading test for multi-span steel beam on which distributed and concentrated loads act was conducted. The strain data for verification was measured by FBG sensors that have multiplexing technology. The analysis of the accuracy of strain estimation for distributed and concentrated loads and the errors by considering the number of measured points used in the estimation were conducted. In the maximum strain points, the strains could be estimated with the errors of 5.89% (loading step 1) and 6.26% (loading step 2). In case of decreasing the number of sensors, it was also confirmed that the errors increased (0.26~0.37%). Through the curve fitting method, it is possible to estimate the strain distribution (maximum strains and their locations) of multi-span beam for unspecific loads and go over the limit of the analytical estimation method which is suitable for specific distributed loads.

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors (광섬유 센서를 이용한 경량전철 교량의 사용성 평가)

  • Kang, Dong-Hoon;Chung, Won-Seok;Kim, Hyun-Min;Yeo, In-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.305-312
    • /
    • 2007
  • Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.

Accuracy improvement of FBG temperature sensor system for usage in electric power systems (전력 시스템 보호를 위한 광섬유 격자 온도센서의 정밀도 개선)

  • Lee, Hyun-Wook;Lee, Jun-Ho;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.421-425
    • /
    • 2005
  • A distributed FBG temperature sensor system was constructed for the use in protection of electric power system. A F-P wavelength tunable filter is used converting temperature-induced wavelength variations to temporal peak locations. We used Gaussian line-fitted algorithm to alleviate the error caused by quantization and electrical noises. The experimental results showed much better accuracy than the raw peak-detection scheme.

  • PDF

Flexural Behavior of Reinforced Concrete Beam with Hybrid FRP Rods (Hybrid FRP Rod로 보강된 철근콘크리트 보의 휨 거동)

  • Kwak, Kae-Hwan;Jang, Hwa-Sup;Yang, Dong-Oun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.327-330
    • /
    • 2005
  • In this study, the nature of brittleness, one of the main problems of GFRP(Glass Fiber Reinforced Plastic) Re-bar, is improved. Therefore, Hybrid GFRP Rod is developed by attaching FBG sensor to the new GFRP Rod with toughness, essential for flexural reinforcement of the concrete. The test was performed with specimens of Hybrid GFRP Rod. According to the test, data measured by electric gauge sensor are compared with data measured by FBG sensor.

  • PDF

단일모드 FBG(fiber bragg grating)을 이용한 저주파수 수중음향 센서

  • 김경복;김성순;곽계달;이상배;최상삼
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.246-247
    • /
    • 2000
  • 최근에 개발된 광섬유 격자소자(FBG)를 이용한 광섬유 수중 음향센서는 기존의 광섬유 센서가 지니고 있는 우수한 장점들을 지니고 있을 뿐만 아니라, PZT센서가 검출할수 없는 저주파수(30Hz∼300Hz)특성에서도 우수한 신호 감지효과를 지니고 있으며, 특히 군사용으로 사용될 수 있는 저주파 신호 검출에 실용화를 기대 할수 있으며, 센서 어레이(array)를 통하여 고감도 다중화로 발전될 수 있다.

  • PDF

The Optical Circulator Using FBG (FBG를 이용한 광 써큘레이터에 관한 연구)

  • Kim, Kee-Joong;Son, Yong-Hwan;Jung, Jin-Ho
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.122-125
    • /
    • 2003
  • In this paper, we propose the optical circulator using OADM(optical add-drop multiplexer) and consider its output characteristics by computer simulation. The results obtained by computer simulation, show that the proposed optical circulator operates in WDM wavelength ranges (1530nm -1560nm) well.

  • PDF

Intensity-modulated Multiplexing of FBG Sensors (광 세기 변조 다중화 된 브래그 격자 센서)

  • 서정민;이정주;권일범
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.324-325
    • /
    • 2003
  • 광섬유 브래그 격자 센서(Fiber Brags Grating Sensor: FBG Sensor)는 여타 광섬유 센서와 같이 가볍고 저렴하며 주위의 전자기적 잡음에 무관한 장점과 더불어 측정대상이 반사광의 파장변화이므로, 광섬유 연결부나 실험장치들에 의해 생기는 광 손실이나 잡음에 대해서 강인한 측정을 할 수 있다. 그리고 파장변화가 변형률이나 온도변화에 선형적으로 나타나므로, 센서로서 많은 연구가 진행되고 있다. 특히, 구조물의 내부에 삽입하여 구조물 스스로 외부의 환경변화를 감지하여 필요한 동작을 수행하는 지능형 구조물(Smart Structure)에 적합한데, 이를 위해선 구조물의 여러 지점을 측정해야 하므로, 브래그 격자 여러개를 한 시스템에서 사용하는 다중화(Multiplexing)가 필수적이다. (중략)

  • PDF

Protection Method for Diameter-downsized Fiber Bragg Gratings for Highly Sensitive Ultraviolet Light Sensors

  • Seo, Gyeong-Seo;Ahn, Tae-Jung
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.221-225
    • /
    • 2018
  • We suggested the use of miniature hollow glass tubes having high ultraviolet (UV) transmission characteristics for the protection of optical-fiber-type UV sensors. We have recently proposed a highly sensitive optical sensor in the UV spectral range, using a fiber Bragg grating (FBG) coated with an azobenzene polymer as the photoresponsive material. In this study, we used UV-transparent miniature glass tubes to protect the etched FBG with the azobenzene polymer coating. This technique will be very useful for protecting various fiber-based UV sensors.