Browse > Article

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors  

Kang, Dong-Hoon (Korea Railroad Research Institute)
Chung, Won-Seok (Korea Railroad Research Institute)
Kim, Hyun-Min (Korea Railroad Research Institute)
Yeo, In-Ho (Korea Railroad Research Institute)
Publication Information
Abstract
Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.
Keywords
FBG; Railway Bridge; Light Weight Transit(LRT); EMI; Serviceability;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 이덕영, 이안호, 송달호, '경량전철 개론', 노해출판사, (2006)
2 정원석, 강동훈, 최은수, 김현민, '광섬유 격자 센서를 이용한 철도 판형교의 증속 시험', 한국강구조학회 논문집, 제17권 제6호, pp. 681-688, (2005)
3 A. Mita and I. Yokol, 'Fiber Bragg grating accelerometer for structural health monitoring,' Fifth International Conference on Motion and Vibration Control 2000, Sydney, Australia, (2000)
4 E. Udd, 'Fiber optic smart structures,' John Wiley and Sons, New York, (1995)
5 한국철도시설공단, '철도설계기준(철도교편)', (2004)
6 UlC Code 776-1R, 'Loads to be considered in railway bridge design,' 4th Edition, International Union of Railway, (1994)
7 ERRI D 214 RP9, 'Rail bridges for speeds v>200km/h,' European Rail Research Institute, (1999)
8 정원석, 김성일, 김남식, 이희업, '간섭형 long-gage 광섬유 센서를 이용한 콘크리트 구조물의 모니터링', 한국철도학회논문집, 제9권, 제4호, pp. 467-472, (2006)   과학기술학회마을