• 제목/요약/키워드: FACTS(Flexible-AC Transmission System)

검색결과 90건 처리시간 0.024초

시뮬레이터급 TCSC 제어기 설계 및 구현 (The Design and Implementation of TCSC Control Hardware for KERI Simulator)

  • 전진흥;김광수;김지원;전영환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.158-161
    • /
    • 2003
  • KERI simulator is a analog simulator for power system at KERI power system division lab. It consist of many power system components, which are a 380V 5kVA generators, scale-downed transmission line modules, transformers, switches, PACTS(Flexible AC Transmission System) devices. As a FACTS device module, 20kVA TCSC(Thyristor Controlled Series Compensator) module was designed and implemented. In this paper, we present the design and implementation of TCSC control hardware for KERI simulator

  • PDF

20kVA 시뮬레이터급 TCSC 설계 및 제작 (The Design and Implementation of 20kVA TCSC Simulator)

  • 전진홍;김광수;김지원;전영환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.154-157
    • /
    • 2003
  • In this study, we design and implement the 20kVA TCSC(Thyrister Controlled Series Compensator) simulator It was tested on the KERI simulator The KERI simulator is a analog simulator for power system at the KERI power system division lab. It consist of many power system components, which are a 380V 5kVA generators, scale-downed transmission line modules, transformers, switches, FACTS(Flexible AC Transmission System) devices. In this paper, we present the design and implementation of 20kVA TCSC simulator and its basic test results.

  • PDF

신경회로망을 이용한 SVC 계통의 안정화에 관한 연구 (A Study on the SVC System Stabilization Using a Neural Network)

  • 정형환;허동렬;김상효
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.49-58
    • /
    • 2000
  • 본 논문에서는 FACTS(Flexible AC Transnission System)로 분류되는 여라 기기중 기존의 전압제어 및 무효 전력보상기들이 가지고 있는 바속응성과 불연속성 문제를 해결해줄 수 있는 정지형 무효전력 보상가(Static Var Compensator : SVC)를 포함한 전력계통에 신경회로망 제어기를 적용하여 안정화에 관하여 연구하였다. 제안된 신경회로망 제어기는 오차와 오차변화량을 입력하는 오차역전과 학습 알고리즘을 사용하고, 학습시간올 단축하기 위해 모멘텀 방법을 사용하였다. 제안된 방법의 강인섬을 입증하기 위해 중부하시 및 정상부하시에 초기 전력을 변동시킨 경우와 초기에 회천자각을 변동시킨 경우에 대하여 시스렘의 회전자각, 각속도 편차 특성 및 단 자전압의 동특성을 고찰하여 다른 시스템보다 응답특성이 우수합을 보였다.

  • PDF

전력계통용 파워일렉트로닉스 기기

  • 대한전기협회
    • 전기저널
    • /
    • 통권277호
    • /
    • pp.69-77
    • /
    • 2000
  • 최근 전력설비 운용상의 여러 가지 과제에 대한 유망한 해결책으로서 파워일렉트로닉스 기기를 사용한 FACTS(Flexible AC Transmission System)가 주목을 받고 있다. 그 중에서도 자려식 변환기를 사용한 FACTS기기는 계통의 유효전력$\cdot$무효전력을 계통의 상태에 의존하지 않고 자유롭게 제어할 수 있어, 계통운용의 유연성을 비약적으로 확대할 수 있는 가능성이 있다. 미쓰비시전기는 전력기기간 계통에서의 자려식 변환기 응용의 파이어니어로서 1991년 간사이전력(주) 태산개폐소에 80Mvar SVG(전지형 무효전력발생장치)를 납품하였으며 또한 자원에너지청의 ''연계강화기술개발'' 보조사업으로 도쿄전력(주)을 비롯하여 전력회사 각사, 전원개발(주)와 (재)전력중앙연구소의 지도 하에 3단자 BTB(Back to Back) 실증시스템용으로 세계 최초의 6인치 GTO(Gate Turn-off Thyristor)를 사용한 53MVA의 자려식 변환기를 제작납품하여 수백MVA 클래스의 자려식변환기 제작기술을 확립하였다. 또한 최근에는 동사가 개발한 신소자 GCT(Gate Commutated Turn-off Thyristor)는 지금까지 대용량 자려식 변환기의 커다란 과제였던 운전손실을 반감할 수 있을 것으로 기대되고 있다. 한편 배전 분야에서는 전압변동, 고조파, 순간전압강하 등의 과제가 증가하고 있어, 미쓰비시전기는 이에 응할 수 있는 파워일렉트로닉스 기기로서 콤팩트 SVG(Static Var Generator), SSTS(Solid-state Transfer Switch), 액티브필너를 다수 납품하여 전력품질문제 해결에 공헌하고 있다.

  • PDF

강진 UPFC 고장실적 분석 (The analysis of Kangjin UPFC faults)

  • 김수열;이원교;장병훈;전영수;이세일;배정현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.450-452
    • /
    • 2006
  • 한전 전력연구원은 1990년대부터 FACTS(유연송전시스템 : Flexible AC Transmission System)을 연구해 온 이래 80MVA UPFC(종합조류제어기 : Unified Power Flow Controller)를 2003. 5월 신강진전력소관내 강진변전소에 준공하였다. 효성과 지멘스의 기술제휴를 통해 개발된 강진변전소 UPFC를 통해 FACTS 엔지니어링, 제어 알고리즘 및 유지보수 기술이 확보되었다. 초창기 안정화운전 기간동안 제어핵심기술과 일부예비품의 미확보가 가용율(Availability)에 큰 영향을 미쳤으나, 현재 강진 UPFC는 안정적으로 운전되고 있다. 본 논문에서는 그 동안의 강진 UPFC의 고장내용을 종합분석하고, 가용율을 정리하였다.

  • PDF

RTDS(Real Time Digital Simulator)를 이용한 UPFC(Unified Power Flow Controller) 모델링 (UPFC Modelling on RTDS)

  • 김광수;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.47-50
    • /
    • 2001
  • In order for effective operation of existing power systems, introduction of the so-called FACTS(Flexible AC Transmission System) such as SVC and UPFC etc, is unavoidable. The UPFC(Unified Power Flow Controller) is composed of STATCOM(Static Compensator) and SSSC(Static Synchronous Series Compensator), and is used to control the magnitude and phase angle of injected sources which are connected bothin series and in parallel with the transmission line to control the power flow and bus voltages. This paper presents a UPFC simulation on RTDS. The voltage and phase angle of a system have been analyzed by regulating the firing angle inside the UPFC.

  • PDF

다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석 (Dynamic Characteristics Analysis of Multi-bridge PWM Inverter SSSC)

  • 한병문;박덕희;김성남
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권6호
    • /
    • pp.296-302
    • /
    • 2001
  • This paper proposes a SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

직렬형 FACTS 설비를 포함하는 전력시스템의 RCF 해석법에 기초한 감도해석 (Sensitivity Analysis of Power System Including Series FACTS Device Based on RCF Method)

  • 김덕영
    • 한국정보통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.624-631
    • /
    • 2011
  • 본 논문은 Exciter와 Power System Stabilizer(PSS)를 포함하는 발전기 제어장치와 싸이리스터에 의한 불연속 스위칭 동작을 하는 직렬형 Flexible AC Transmission System(FACTS) 설비인 Thyristor Controlled Static-var Compensator(TCSC)를 포함하는 전력계통의 고유치 해석과 안정도 개선을 위한 고유치 감도계수를 이산 시스템에서의 해석방법을 사용하여 해석하였다. 이산 시스템에서의 해석방법으로는 Resistive Companion Form(RCF) 해석법을 사용하였으며, 상태천이 방정식을 사용하여 감도해석에 필요한 계산 알고리즘을 제시하였고, 연속시스템에서의 해석결과와 비교하였다. TCSC의 스위칭 동작이 고려되지 않는 연속 시스템에서의 해석결과와 달리, 이산 시스템에서의 해석결과 스위칭 동작의 영향으로 제어기 정수에 대한 감도해석 결과가 일정한 방향성을 가지면서 주기적으로 변화하는 것을 알 수 있었다. 또한 중요 진동모드에 대한 제어기정수의 감도계수 값이 연속시스템에서의 해석결과와 달리 싸이리스터의 주기적 스위칭 동작에 의해 다른 값을 가지면서 주기적으로 진동하는 것을 알 수 있었다.

UPFC의 국내 계통 적용에 관한 연구 : Pilot Plant (The First Introduction of UPFC to the KEPCO Power Network in Korea : Pilot Plant)

  • 유현호;김준모;이학성;임성주;김수열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.307-311
    • /
    • 2002
  • 최근의 전력 공급 시장에서는 전력 공급의 유연성을 확보함과 동시에 고품질의 전력을 높은 신뢰성을 가지면서 수용가에 공급하는 송전기술에 대한 관심이 높아지고 있다. 이러한 시장의 요구에 부응하여 송전 시스템의 유효전력 및 무효전력을 능동적으로 제어할 수 있는 FACTS(Flexible AC Transmission System) 기기의 개념이 도입되었다 FACTS기술의 개념은 기존에 수동적으로 제어하였던 선로의 전압, 임피던스 및 위상각을 능동적으로 제어함으로써 전력공급의 유연성 및 신뢰성을 높이는 것이다 국내에서는 과거 일련의 project를 통하여 인버터형 FACTS 기기외 국내 적용을 위한 연구를 수행해 왔으며, 그 결과를 토대로 한전 전력연구원, (주)효성, 미국 Siemens사 및 국내 연구소와 협동연구의 형태로 한전의 154kV 계통에 적용되는 80MVA급 UPFC(Unified Power Flow Controller) pilot plant project를 진행하고 있다. 본 pilot plant project를 통하여 인버터형 FACTS 기기인 UPFC를 실제계통에 설치, 운영함으로써 향후 한국의 기간 계통인 345kV 송전 시스템에 적용할 시스템의 사양 및 운용전략을 도출할 계획이다. 본 논문에서는 국내 계통의 특징, pilot plant가 설치될 지역의 계통현황 및 기기의 사양을 소개하고 기기의 현장 설치 및 시험 진행 상황에 대하여 설명하였다.

  • PDF

Modeling and Analysis of the KEPCO UPFC System by EMTDC/PSCAD

  • Yoon, Jong-Su;Kim, Soo-Yeol;Chang, Byung-Hoon;Lim, Seong-Joo;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.148-154
    • /
    • 2003
  • This paper describes the development of KEPCO's 80MVA UPFC electromagnetic transient model and the analysis of its performance in the actual Korean power system. KEPCO's 80MVA UPFC is currently undergoing installation and will be ready for commercial operation from the year 2003. In order to apply a new FACTS device such as the UPFC to the actual power system, the utility needs, in advance, both load flow stability studies and transient studies. Therefore, KEPRI, the research institute of KEPCO, developed a detailed transient analysis model that is based on the actual UPFC S/W algorithm and H/W specifications. This simulation model is implemented by an EMTDC/PSCAD package. The results of the simulation show the effectiveness of UPFC operation in the KEPCO power system.