• Title/Summary/Keyword: FAC

Search Result 326, Processing Time 0.023 seconds

DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH, ORIFICE DISTANCE AND MATERIAL

  • Moon, Jeong-Ho;Chung, Hung-Ho;Sung, Ki-Woung;Kim, Uh-Chul;Rho, Jae-Seong
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.375-384
    • /
    • 2005
  • To investigate the flow-accelerated corrosion (FAC) dependency of carbon steel (A106 Gr. B) and low-alloy steels (1Cr-1/2Mo, 21/4Cr-1Mo) on pH, orifice distance, and material, experiments were carried out. These experiments were performed using a flow velocity of 4 m/sec (partly 9 m/sec) at pH $8.0\~10.0$ in an oxygen-free aqueous solution re-circulated in an Erosion-Corrosion Test Loop at $130^{\circ}\;{\ldots}$ for 500 hours. The weight loss of the carbon steel specimens appeared to be positively dependent on the flow velocity. That of the carbon and low-alloy steel specimens also showed to be distinguishably dependent on the pH. At pH levels of $8.0\~9.5$ it decreased, but increased from 9.5 to 10.0. Utility water chemistry personnel should carefully consider this kind of pH dependency to control the water system pH to mitigate FAC of the piping system material. The weight loss of the specimens located further from the orifice in the distance range of $6.8\~27.2$ mm was shown to be greater, except for 21/4Cr-1Mo, which showed no orifice distance dependency. Low alloy steel specimens exhibited a factor of two times better resistance to FAC than that of the carbon steel. Based on this kind of FAC dependency of the carbon and low-alloy steels on the orifice distance and material, we conclude that it is necessary to alternate the composition of the secondary piping system material of NPPs, using low-alloy steels, such as 21/4Cr-1Mo, particularly when the system piping has to be replaced.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

Integrity Assessment of Stationary Blade Ring for Nuclear Power Plant (원자력 발전소용 블레이드링 건전성 평가)

  • Park, Jung-Yong;Chung, Yong-Keun;Park, Jong-Jin;Kang, Yong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.85-89
    • /
    • 2004
  • The inner side between HP stationary blades in #1 turbine of Nuclear Power Plant A is damaged by the FAC(flow assisted corrosion) which is exposed to moisture. For many years the inner side is repaired by welding the damaged part, however, FAC continues to deteriorate the original material of the welded blade ring. In this study, we have two stages to verify the integrity of stationary blade ring in nuclear power plant A. In the stage I, replication of blade ring is performed to survey the microstructure of blade ring. In the stage II, the stress analysis of blade ring is performed to verify the structural safety of blade ring. Throughout the two stages analysis of blade ring, the stationary blade ring had remained undamaged.

  • PDF

Evaluation of Piping Integrity in Thinned Main Feedwater Pipes

  • Park, Young-Hwan;Kang, Suk-Chull
    • Nuclear Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.67-76
    • /
    • 2000
  • Significant wall thinning due to flow accelerated corrosion(FAC)was recently reported in main feedwater pipes in 3 Korean pressurized water reactor(PWR) plants. The main feedwater pipes in one plant were repaired using overlay weld method at the outside of pipe, while those in 2 other plants were replaced with new pipes. In this study, the effect of the wall thinning in the main feedwater pipes on piping integrity was evaluated using finite element method. Especially, the effects of both the overlay weld repair and the stress concentration in notch-type thinned area on the piping integrity were investigated. The results are as follows : (1) The piping load carrying capacity may significantly decrease due to FAC. In special, the load carrying capacity of the main feedwater pipe was reduced by about 40% during about 140 months operation in Korean PWR plants. (2) By performing overlay weld repair at the outside of pipe, the piping load carrying capacity can increase and the stress concentration level in the thinned area can be reduced.

  • PDF

Influence of Tempering Temperature and Microstructure on Wear Properties of Low Alloy PM Steel with 1-2% Ni Addition

  • Tekeli, Suleyman;Gural, Ahmet;Guru, Metin
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1004-1005
    • /
    • 2006
  • The effect of tempering temperature and microstructure on dry sliding wear behavior of quenched and tempered PM with 0.3% graphite and 1-2% Ni steels was investigated. The sintered specimens were quenched from $890^{\circ}C$ and then tempered at $200^{\circ}C$ and $600^{\circ}C$ for 1 hr. Wear tests were carried out on the quenched$\neq$tempered specimens under dry sliding wear conditions using a pin-on-disk type machine at constant load and speed. The experimental results showed that the wear coefficient effectively increased with increasing tempering temperature and decreased with increasing Ni content.

  • PDF

Experimental Evaluation on Seismic Performance of Filled Composite Beam - to - Forming Angle Composite Column Connections (충전형 합성보와 포밍앵글 기둥 접합부의 내진성능에 대한 실험적 평가)

  • Kim, Hyoung Seop;Lee, Kyungkoo;Koo, Jimo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.71-77
    • /
    • 2016
  • In this study, the seismic performance of connections between filled composite beam (CG beams) and forming angle composite (FAC) column was experimentally evaluated. First, the bending tests were conducted on two CG beams and the axial tests were conducted on two FAC columns. Then, based on these preliminary test results, the cyclic loading test were performed on two interior connections between CG beam and FAC column. The main difference of two specimens is the plate shape of the CG beam. The test results showed that both specimens achieved the maximum story drift capacity over 0.04 radian which is required for special moment frame.

Novel computational approaches characterizing knee physiotherapy

  • Kim, Wangdo;Veloso, Antonio P.;Araujo, Duarte;Kohles, Sean S.
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-66
    • /
    • 2014
  • A knee joint's longevity depends on the proper integration of structural components in an axial alignment. If just one of the components is abnormally off-axis, the biomechanical system fails, resulting in arthritis. The complexity of various failures in the knee joint has led orthopedic surgeons to select total knee replacement as a primary treatment. In many cases, this means sacrificing much of an other-wise normal joint. Here, we review novel computational approaches to describe knee physiotherapy by introducing a new dimension of foot loading to the knee axis alignment producing an improved functional status of the patient. New physiotherapeutic applications are then possible by aligning foot loading with the functional axis of the knee joint during the treatment of patients with osteoarthritis.

Sharp-line Electronic Spectroscopy and Ligand Field Analysis of Cr(III) Complexes with Amino Acid Ligands

  • 박성진;최영근;한승석;이규왕
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.12
    • /
    • pp.1475-1478
    • /
    • 1999
  • Ligand field calculations have been performed based on the data from the absorption and low temperature sharp-line excitation spectra of fac-Cr(gly)₃, fac-Cr(L-serine)₃ · 2H₂O and fac-Cr(L-leucine)₃·2H₂O. The optimized ligand field parameters for all complexes show that the carboxylate and the amino groups are moderate σ-donor. The values of $e_{{\pi}O}$ are typical of other complexes with carboxylate ligands. However, the π-interaction of carboxylic oxygen to the chromium in serinato complex is much weaker than that of other complexes. The inclusion of π-anisotropy is necessary to adequately explain the large doublet splittings.

SUNSPOT EVOLUTION IN THE VICINITY OF A LARGE SOLAR FLARE IN AR 6891

  • ALMLEAKY Y. M.;MALAWI A. A.;BASURAH H. M.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.317-319
    • /
    • 1996
  • Utilizing a Calcium filter, a large two ribbon flare of an importance 2.5Xj31? was recorded at. King Abdul-Aziz University Solar Observatory (KAAUSO) at the 30th of October 1991. This chromosphenc flare observation, which is of special importance since it is rarely reported, was for a flare that occurred near the south west of the equator at the vicinity of a large sunspot group on an active region known as AR 6891. The observed foot points of this flare had a strange behavior in which the separating motion of the ribbons were not typical of most flares, rather were nearly orthogonal. In this article we present the characteristics of the main sunspot group of this active region and try to investigate its evolution and fragmentation with time. Information regarding magnetic fields and velocity fields are necessary to understand the restructuring of the magnetic field pattern and plasma motion, and hence the changes that could lead to the occurrence of such an interesting flare.

  • PDF

Hydrological aspects of a non-managed artificial forest watershed of Chamaecyparis obtuse Endl.

  • Otsuki, Kyoichi;Higashi, Tomohiro;Ide, Junichiro;Sato, Nobuhiro;Kume, Atsushi;Ogawa, Shigeru
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2003.05a
    • /
    • pp.81-88
    • /
    • 2003
  • In this report, we first introduce the plan of the Japanese Council of University Experimental Forests to establish Long-Term Forest Hydrological Network, and propose the cooperation between Japan Society of Hydrology and Water Resources (JSHWR) and Korean Water Resources Association (KWRA) to fulfill the plan. Then we introduce our hydrological researches conducted in a non-managed artificial forest watershed of Kyushu University Forests in 2002. Though hydrological phenomena have not sufnciently investigated, we introduce the hydrological aspects obtained in 2002 to initiate cooperative researches on Forest Ecosystems with KWRA.

  • PDF