• Title/Summary/Keyword: FA test

Search Result 250, Processing Time 0.024 seconds

3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle (3T MR 스핀에코 T1강조영상에서 적정의 숙임각)

  • Bae, Sung-Jin;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). Materials and Method : T1-weighted images of the cerebrum of brain were obtained from 50$^\circ$ to 130$^\circ$ FA with 10$^\circ$ interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp ($\frac{-TR}{T1}$) and Ernst angle cos $\theta$ = exp ($\frac{-TR}{T1}$). Results : The SNR of WM at 130$^\circ$ FA is approximately 1.6 times higher than the SNR of WM at 50$^\circ$. The SNR of GM at 130$^\circ$ FA is approximately 1.9 times higher than the SNR of GM at 50$^\circ$. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120$^\circ$ FA, the SNR of GM started decreasing at less than 110$^\circ$. The highest SNRs of WM and GM were obtained at 130$^\circ$ FA. The highest CNRs, however, were obtained at 80$^\circ$ FA. Conclusion : Although SNR increased with the change of FA values from 50$^\circ$ to 130$^\circ$ at 3T SE T1WI, CNR was higher at 80$^\circ$ FA than at the usually used 90$^\circ$ FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  • PDF

Evaluation on Workability and Compressive Strength Development of Concrete Using Modified Fly-Ash by Vibration Grinding (진동분쇄를 사용한 개질 플라이애시 콘크리트의 유동성 및 압축강도 발현 평가)

  • Ahn, Tae-Ho;Yang, Keun-Hyeok;Jeon, Young-Su
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.66-74
    • /
    • 2021
  • The objective of this study is to evaluate the practical application potential and limitations of the modified fly ash(MFA) by vibration grinding as a partial replacement of ordinary portland cement(OPC). The test parameters investigated were the replacement level of fly ash(FA) and FA for OPC, varying from 10% to 40%, and curing temperatures of 5, 20, and 40℃. The various characteristics(including slump, air content, bleeding, setting time, compressive strength development, and hydration products) of MFA concrete were measured and then compared with those of the concrete with conventional FA. Test resul ts showed that the MFA prefers to FA in reducing the bl eeding of fresh concrete and enhancing the compressive strength gain at an early age. The compressive strength ratios between MFA and FA concrete specimens at an age of 1 day were 135%, 146%, and 111% at the curing temperatures of 5, 20, and 40℃, respectively. The corresponding ratios at an age of 28 days were approximately 110%, regardless of the curing temperatures. The X-ray diffraction analysis also revealed less calcium hydroxide products in MFA pastes than in FA pastes.

Measurement of Adhesion Strength of Polyurethane Foam to Surface-Treated Carbon Steel and Effect of Water Vapor Absorption (발포 폴리우레탄과 탄소강과의 접착 강도 측정 및 수증기 흡착의 영향)

  • 김장순;조재동;임연수
    • Polymer(Korea)
    • /
    • v.27 no.4
    • /
    • pp.340-348
    • /
    • 2003
  • A previous stud-pull test was modified to measure the bond strength of polyurethane foam to carbon steel substrate. This test was appropriate in that the specimen foamed on Zn phosphated steel (0.95 kN) was broken at higher load than that of smooth galvanizing treated steel (0.38 kN). Among the samples foamed on the substrate atvarious preheating temperatures, the polyurethane foam to the steel held over 60$^{\circ}C$ exhibited very high bond strength. The samples were exposed at water vapor absorption, and, then, their bond strengths were measured. The adhesion was significantly reduced in the samples foamed on the steel at temperatures below 40$^{\circ}C$ and above 70$^{\circ}C$. For the polyurethane foams formulated with two blowing gases, the adhesion was higher by 0.03 kN in the samples with HCFC-l4lb than that with HFC-245fa. When the these samples were exposed at water vapor soaking, the reduction of the bond strength for the HFC-245fa blown sample was negligible due to smaller area fraction of void area filled with gas at interfacial area. Consequently, it was found that adhesion of polyurethane foam to metal substrate was determined by variation of microstructural features with substrate preheating, surface treatment type of blowing agent.

An Experimental Study on the Application of Fly Ash for Lining Concrete (라이닝콘크리트에서의 FA적용에 관한 실험적 연구)

  • 최세진;임정열;김완영;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.151-154
    • /
    • 1999
  • The lining concrete of water tunnel is a structure that is constructed to prevent from corroding of the rock around tunnel and reduce the deterioration of geology by flowing water, and to improve the durability of tunnel, which must not only economy, stability but also satisfy the engeneering properties of concrete. This is an experimental study to analyze th usability of fly in the tunnel lining concrete. For this purpose, after select the mix proportion of plain concrete and concrete using fly ash(the replacement of 15 and 30% by weight of cement) to satisfy slump, air content and compressive strength through the mix design, the test of slump, setting time, compressive strength, tensile strength, drying shrinkage and adiabatic temperature rise was performed. According to test results, it was found that FA 15 concrete was more effective than the others to reduce drying shrinkage as well satisfy other engineering properties.

  • PDF

A Study on the Properties of Mixture Proportion and Compressive Strength of Concrete with the Kind of Mineral Admixtures (혼화재 종류에 따른 콘크리트의 배합 및 압축강도 특성에 관한 연구)

  • Lee Eun-Hi;Shon Myeong-Soo;Han Min-Cheoi;Cha Cheon-Soo;Kim Seong-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.51-54
    • /
    • 2004
  • This paper investigated the results of mixture proportion and compressive strength of concrete incorporating mineral admixtures. W/B and contents of mineral admixtures were selected as test parameters. According to test results, use of mineral admixtures resulted in a reduction of fluidity and air contents caused by increased fine particles and absorption effect of FA on reduction of AE agent. Thus, increase of SP and AE agent was needed to maintain the same fluidity and air content as plain concrete. At early stage, use of CKD was beneficial to the compressive strength while at 28days. incorporation of FA and BS had favorable effect on the compressive strength.

  • PDF

Characteristics of Adiabatic Temperature Rise for Concrete according to FA Cement and CGS Replacement Rate (FA시멘트 및 CGS 치환율에 따른 콘크리트의 단열온도상승 특성)

  • Baek, Sung-Jin;Hu, Yun-Yao;Kim, Su- Hoo;Han, Jun-Hui;Yoon, Chee Whan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.117-118
    • /
    • 2022
  • In this study, adiabatic temperature rise of concrete depending on binder compositions and CGS contents is studied to provide informations for CGS low-heating aggregate and mixture designs for upper and lower placement lifts. Test nresults indicate that it is desirable to apply the combination of binders between top and bottom lift. For top lift, SESC or ESC is recommended, and for bottom lift, FAC+CGS 50 % is good for material composition.

  • PDF

The Properties of Internal Temperature of Paste and Concrete according to Component Ratio Variation of Ternary System Cement (3성분계 시멘트의 구성비 변화에 따른 페이스트 및 콘크리트의 내부온도 특성)

  • Kim, Yeon-Seung;Kim, Dong-Hyeok;Jee, Nam-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.797-807
    • /
    • 2008
  • For this study, the semi-adiabatic temperature rising test is accomplished by using ternary system cement (OPC, BFS, FA) reducing temperature crack. Two tests are conducted; one is for the paste test, and the other is for the concrete test. As the results of paste tests, using fly ash is better to reduce hydration temperature than doing blast furnace slag. In the case of the paste mixed ternary system cement, the more fly ash is mixed and the less blast furnace slag is used, the lower the temperature is. The less the mixture ratio of blast furnace slag is and the more the mixture ratio of fly ash is, the later the temperature rising velocity and descending velocity are. Besides, the temperature is lower if water/binder ratio is high. The use of ternary system cement has the retardation effect of temperature rising because the time to reach the maximum temperature is in the order of OPC100, binary system cement, and ternary system cement. From the test, the maximum temperature of concrete used ternary system cement is $8{\sim}11^{\circ}C$ lower than that of concrete used OPC100. Moreover, temperatures rising velocity and descending velocity of ternary system cement range $47{\sim}51%$ and $37{\sim}42%$ compared with OPC100. The specimen of concrete shows remarkable low internal temperature and slow temperature rising velocity and descending velocity compared with the specimen of paste because it is that temperature loss of concrete is much more than paste specimen according to aggregates.

The Strength Characteristics of Activated Multi-Component Cement with Kaolinite (카올린을 혼합한 활성화된 다성분계 시멘트의 강도 특성)

  • Kim, Tae-Wan;Kim, Im-Gon
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.593-600
    • /
    • 2016
  • The paper presented investigates the effects of kaolinite on strength properties of alkali-activated multi-component cement. The binders of this study was blended of ground granulated blast furnace slag (GGBFS), fly ash (FA), silica fume (SF) and kaolinite (KA). In this study, the specimens of combination of 20%~70% GGBFS, 10%~60% FA, 10% SF (constant ratio) and 10%~50% KA binder were used for strength properties tests. The water/binder ratio was 0.5. The binders (GGBFS + FA + SF + KA) was activated by sodium hydroxide (NaOH) and sodium silicate ($Na_2SiO_3$) was 10% by total binder weight (10% NaOH + 10% $Na_2SiO_3$). The research carried out is on the compressive strength, water absorption, ultrasonic pulse velocity (UPV) and X-ray diffraction (XRD). The compressive strength decreased as the contents of KA increase. One of the major reason for this is the low reactivity of KA compared with other raw materials used as precursors such as GGBFS or FA. The presence of remaining KA indicates that the initially used quantity has not fully reacted during hydration. Moreover, the results have indicated that increased of KA contents decreased UPV under all experimental conditions. The drying shrinkage and water absorption increased as the content of KA increase. Test result clearly showed that the strength development of multi-component blended cement were significantly dependent on the content of KA and GGBFS.

Evaluation of Relationship between Strength and Resistance to Chloride in Concrete Containing Fly Ash with Ages (Fly Ash를 혼입한 콘크리트의 재령에 따른 강도와 염화물 저항능력간의 상관관계 평가)

  • Yoon, Yong-Sik;Park, Jae-Sung;Hwang, Chul-Sung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.53-60
    • /
    • 2017
  • Fly ash(FA) which is a byproduct in the coal combustion in thermal power plant contributes to pore structure densification due to pozzolanic reaction, and this leads to long-term strength development and excellent resistance to chloride penetration. In the work, compressive strength and chloride resistance in OPC(Ordinary Portland Cement) and FA-based concrete are evaluated, and the relationships are investigated considering ages. For the work, 3 different W/B (Water to Binder) ratios of 37%, 42%, and 47% are prepared, and 3 substitution ratio of fly ash(0%, 30%, and 50%) are considered as well. At the age of 28 days and 180 days, test results of compressive strength, diffusion coefficients based on Tang's method, and passed charges referred to ASTM C 1202 and KS F 2711 are obtained. With increasing replacement ratio of FA and decreasing W/B, the resistances to chlorides(diffusion coefficient and passed charge) are improved, and the results at the age of 180 days decrease to only 15% level at the age of 28 days due to pozzolanic reaction in FA 50 mixture, which shows that resistance to chloride is much dependent on age effect than strength development. After 180 days, more clear linear relationships are observed between strength and resistance to chloride.

Analysis of Permeability Characteristics for Fly Ash Concrete According to Aggregate Size and Mixing Ratio (골재크기와 배합비에 따른 플라이애시 콘크리트의 투기특성 분석)

  • Eun-A Seo;Do-Gyeum Kim;Chul-Woo Jung;Ho-Jae Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.400-406
    • /
    • 2023
  • In this study, the relationship between the material properties and air permeability characteristics was examined, an experimental method to analyze the air permeability characteristics was presented, and experimental results were derived. The effects of compressive strength and apparent density of hardened concrete on air permeability characteristics were evaluated experimentally. Focusing on the mix proportions used in nuclear power plant concrete structures, concrete test specimens were manufactured and air permeability characteristics were measured according to changes in binder, maximum aggregate size, and water-binder ratio. The apparent density was over 2,400 kg/m3 for the OPC mix and the FA-35 mix, and the air permeability for both mixes were low, in the range of 0.1-0.2 L/min. On the other hand, in the case of the combination of FA-40, FA-45, and FA-M, the apparent density was measured to be less than 2,400 kg/m3 and the air permeability was measured to be more than 0.3 L/min, experimentally verifying that the apparent density is an important factor in air permeability characteristics.