• Title/Summary/Keyword: F.C.L.

Search Result 1,854, Processing Time 0.037 seconds

Structural Behavior of R/C Beams Strengthened with Carbon Fiber Laminate (탄소섬유판으로 휨보강된 철근 콘크리트보의 구조적 거동)

  • Kim, Sung-Chul;Lee, Hee-Kyoung;Yoo, Seong-Hoon;Kim, Joong-Koo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.607-612
    • /
    • 1998
  • In this study, the behavior of R/C beam strengthened with carbon fiber laminate(C.F.L) is analyzed from the test results. Test parameters are the width, the thickness and the length of C.F.L. and method of construction. The failure mode and ultimate load are analyzed from these measured data. Test results shows that the peak moment of specimens strengthened with C.F.L is increased to 1.43~1.90 times of that of non-rehabilitation specimen. The wider lap width, larger amount of rehabilitation materials, the larger strength is obtained.

  • PDF

An Experimental Study on the Rehabilitation Technics of R/C Flexural Member (철근콘크리트보의 휨내력보강 공법에 관한 실험적 연구)

  • Kim, Sung-Chul;Lee, Hee-Kyoung;Yoo, Seong-Hoon;Kim, Joong-Koo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.715-720
    • /
    • 1997
  • In this study, the behavior of R/C beam strengthened with carbon fiber laminate(C.F.L) is analyzed from the test results. Test parameters ar the width and the thickness of C.F.L. The failure mode and ultimate load are analyzed from these measured data. Test results shows that the peak load of specimens strengthened with C.F.L. is increased to 1.27~2.04 times of that of non-rehabilitation specimen. The wider lap width, large amount of rehabilitation materials, the larger strength is obtained.

  • PDF

GENERALIZED FOURIER-WIENER FUNCTION SPACE TRANSFORMS

  • Chang, Seung-Jun;Chung, Hyun-Soo
    • Journal of the Korean Mathematical Society
    • /
    • v.46 no.2
    • /
    • pp.327-345
    • /
    • 2009
  • In this paper, we define generalized Fourier-Hermite functionals on a function space $C_{a,b}[0,\;T]$ to obtain a complete orthonormal set in $L_2(C_{a,b}[0,\;T])$ where $C_{a,b}[0,\;T]$ is a very general function space. We then proceed to give a necessary and sufficient condition that a functional F in $L_2(C_{a,b}[0,\;T])$ has a generalized Fourier-Wiener function space transform ${\cal{F}}_{\sqrt{2},i}(F)$ also belonging to $L_2(C_{a,b}[0,\;T])$.

CLASSIFICATIONS OF HELICOIDAL SURFACES WITH L1-POINTWISE 1-TYPE GAUSS MAP

  • Kim, Young Ho;Turgay, Nurettin Cenk
    • Bulletin of the Korean Mathematical Society
    • /
    • v.50 no.4
    • /
    • pp.1345-1356
    • /
    • 2013
  • In this paper, we study rotational and helicoidal surfaces in Euclidean 3-space in terms of their Gauss map. We obtain a complete classification of these type of surfaces whose Gauss maps G satisfy $L_1G=f(G+C)$ for some constant vector $C{\in}\mathbb{E}^3$ and smooth function $f$, where $L_1$ denotes the Cheng-Yau operator.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

Cultural Characteristics of a Biosurfactant-Producing Microorganism Pseudomonas aeruginosa F722 (Biosurfactant 생산균주 Pseudomonas aeruginosa F722의 배양특성)

  • ;;;Motoki Kubo
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.2
    • /
    • pp.171-176
    • /
    • 2003
  • Productivity of biosurfactant (rhamnolipid) by Pseudomonas aeuginosa F722 was investigated in the several culture conditions and culture composition. Biosurfactant production by P. aeuginosa F722 was amounted to 0.78 g/l as the result of the nitrogen sources and carbon sources without investing of optimum conditions. As for that one was investigated, biosurfactant production by P. aeruginosa F722 was amounted to 1.66 g/l. Biosurfactant production increased twofold because the composition of a modified C-medium was investigated efficiently. $NE_4$Cl or $NaNO_2$ inorganic nitrogens and yeast extract or trypton organic nitrogens were effective, but others inorganic nitrogens and organic nitrogens tested were not efficient far biosurfactant production by P. aeruginosa F722. The optimum concentration of $NH_4$Cl; inorganic nitrogen and yeast extract; organic nitrogen were 0.05% and 0.1%, respectively. In various carbon sources, others with the exception of hydrophobic property substrate (n-alkane) and hydrophilic property substrate (glucose, glycol) were not found to be effective fur biosurfactant production, and 3.0% was better in yield than other concentration of glucose. This yielded C-to-N ratios between 17 and 20. In our experiment, the highest biosurfactant production by P. aeruginosa F722 were observed in 5 days cultivation, containing glucose 3.0%, $NH_4$Cl 0.05%, and yeast extract 0.1% and C-to-N ratio was 20. Optimal pH and temperature for biosurfactant production were 7.0 and $35^{\circ}C$, respectively. Under the optimal culture conditions with glucose, biosurfactant production was amounted to 1.66 g/l. Velocity of biosurfactant production and strain growth increased after nitrogen depletion. The average surface tension of 30 mN/m after the 3 days of incubation under optimal culture condition was measured by ring tensionmeter.

Physicochemical Characteristics and Acceptability of Commercial Low-Priced French Wines (시판 저가 프랑스 와인의 이화학적 특성 및 기호도)

  • Kim, Eun-Kyung;Kim, In-Yong;Ko, Jae-Youn;Yim, Seoung-Been;Jeong, Yoon-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.11
    • /
    • pp.1666-1671
    • /
    • 2010
  • The physicochemical characteristics and acceptability of various commercial low-priced French wines were determined. A~E wines were manufactured from France and F wine was bottled in Germany using French Cabernet Sauvignon grape species. Sample wines were analyzed for pH, total soluble content, acidity, color, total sugar, total polyphenol and sulfur dioxide. The pH of the wines were ranged from 3.3 to 2.6. The total soluble contents were the highest in wine A (10.25 Brix%), followed by wine C (9.72 Brix%), wine D (9.67 Brix%) and wine B (9.61 Brix%) and were the lowest in wines E and F (9.42 Brix%). In the color analysis, wine F showed the highest L (lightness) and a (redness) value (28.11 and 23.86, respectively). The b (yellowness) value for all the samples studied ranged from 52.17 to 61.05. Wine C (62.24 g/L) and F (69.91 g/L) showed higher total sugar contents, and the total sugar contents of wines D, E, B and A were 48.58, 42.74, 37.74 and 36.99 g/L, respectively. Total polyphenol contents were the highest in wine C (2.59 g/L) and the lowest in wines A and B (1.90 g/L). The contents of sulfite in wine D (68.78 mg/L) were the highest and was the lowest in wine B (58.18 mg/L). The sensory characteristics and preference analysis (sourness, bitterness, sweetness, astringent taste, aroma, color and overall acceptability) of the red wines used in this study were determined by 15 panelists using the 7-point hedonic scale. Sourness of wines ranged between 3.8~4.9 and sweetness of wines D and F (3.0) were the highest amongst the red wines used in this study. Wines D, E and F had the higher scores in overall acceptability of sensory properties and wine E was the highest amongst the wines used in this study.

Fabrication and Oxygen Permeation Properties of ${La_{1-x}Sr_{x}B_{1-{\gamma}}Fe_{\gamma}O_{3-{\delta}}$(B=Co, Ga) Perovskite-Type Ceramic Membranes (${La_{1-x}Sr_{x}B_{1-{\gamma}}Fe_{\gamma}O_{3-{\delta}}$(B=Co, Ga) 페롭스카이트 세라믹 분리막의 제조 및 산소투과특성)

  • 임경태;조통래;이기성;한인섭;서두원
    • Membrane Journal
    • /
    • v.11 no.4
    • /
    • pp.143-151
    • /
    • 2001
  • We have fabricated mixed-ionic conducting membranes, L $a_{0.6}$S $r_{0.4}$ $Co_{0.2}$F $e_{0.8}$ $O_{3-}$$\delta$/ and L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ by the solid state method. Ceramic membranes consisted of perovskite-type structures and exhibited high relative density, >95%. Especially, dense L $a_{0.6}$S $r_{0.4}$Co $O_{3-}$$\delta$/ layer was coated on the L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membranes by using screen printing technique in order to improve oxygen ion flux. We measured oxygen ion flux on uncoated L $a_{0.6}$S $r_{0.4}$ $Co_{0.2}$F $e_{0.8}$ $O_{3-}$$\delta$/, uncoated L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/, and coated L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membranes. The L $a_{0.6}$S $r_{0.4}$ $Co_{0.2}$F $e_{0.8}$ $O_{3-}$$\delta$/ membranes showed the highest flux, 0.26 mL/min.$\textrm{cm}^2$ at 90$0^{\circ}C$, after steady state had been reached. The oxygen flux of coated L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membranes showed higher value, 0.19 mL/min.$\textrm{cm}^2$ at 95$0^{\circ}C$. This flux was as much as 2 or 3 times higher than those of uncoated L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membranes. 3-$\delta$/ membranes.X> 3-$\delta$/ membranes.membranes.

  • PDF

REDEI MATRIX IN FUNCTION FIELDS

  • Jung, Hwanyup
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.19 no.4
    • /
    • pp.319-324
    • /
    • 2006
  • Let K be a finite cyclic extension of $k=\mathbb{F}_q(T)$ of prime degree ${\ell}$. Let ${\tilde{\mathcal{C}}}l_{K,{\ell}}$ be the Sylow ${\ell}$-subgroup of the ideal class group ${\tilde{\mathcal{C}}}l_K$ of $\mathcal{O}_K$. The structure of ${\tilde{\mathcal{C}}}l_{K,{\ell}}$ as $\mathbb{Z}_{\ell}[G]$/<$N_G$>-module is determined the dimensions $${\lambda}_i\;:=dim_{\mathbb{F}_{\ell}}({\tilde{\mathcal{C}}}l_{K,{\ell}}^{({\sigma}-1)^{i-1}}/{\tilde{\mathcal{C}}}l_{K,{\ell}}^{({\sigma}-1)^i})$$ for $i{\geq}1$. In this paper we investigate the dimensions ${\lambda}_1$ and ${\lambda}_2$.

  • PDF