• 제목/요약/키워드: F-SCAN

검색결과 342건 처리시간 0.188초

Dairy cow and calf behavior and productivity when maintained together on a pasture-based system

  • Sarah E., Mac;Sabrina, Lomax;Cameron E.F., Clark
    • Animal Bioscience
    • /
    • 제36권2호
    • /
    • pp.322-332
    • /
    • 2023
  • Objective: We determined the impact of maintaining pasture-based dairy cows and calves together over 100 days on cow milk production, cow and calf behavior, and calf liveweight and carcass quality. Methods: Six Holstein-Friesian cows and their male calves were monitored for 106±8.6 days. Cows were temporarily separated twice a day for milking with calves remaining in the paddock. Cow and calf behaviors were recorded via scan sampling at 6 different timepoints, for the first 7 days and twice a week thereafter. Calves were weighed weekly and immediately processed for meat quality and rumen development analysis at 106±8.6 days. Daily cow milk yields were collected from enrollment until 109±8.6 days (3 days post-weaning). Results: The average daily gain of calves was 1.4±0.73 kg/d, with an average carcass dressing percentage of 59%. Calves had the greatest frequency of observed close proximity to cow and suckling in the first two weeks and decreased with experiment duration. During separation for milking, cow vocalizations and attempts to return to their calf decreased over time. Reticulorumen weight was on target for calf age, but as a proportion of total stomach weight was lower than industry averages of calves the same age due to the larger abomasum. Cows produced an average of 12±7.6 kg of milk yield per day over the 3-days before the calves were weaned and increased to mean of 31±8.3 kg/d the 3 days after weaning, indicating a consumption of close to 20 kg per calf per day. Conclusion: The impact of a pasture-based cow-calf rearing system on cow and calf behavior and the potential for high levels of calf liveweight gain when provided ad-libitum milk and feed were determined. Further research is required to determine the practicality of replicating such systems with large herds and impact on reared calves post-weaning.

아동기 학대 경험이 인지적 정서조절 능력 및 관련 뇌영역 기능에 미치는 영향 (Alterations in Functions of Cognitive Emotion Regulation and Related Brain Regions in Maltreatment Victims)

  • 김승호;이상원;장용민;이승재
    • 생물정신의학
    • /
    • 제29권1호
    • /
    • pp.15-21
    • /
    • 2022
  • Objectives Maltreatment experiences can alter brain function related to emotion regulation, such as cognitive reappraisal. While dysregulation of emotion is an important risk factor to mental health problems in maltreated people, studies reported alterations in brain networks related to cognitive reappraisal are still lacking. Methods Twenty-seven healthy subjects were recruited in this study. The maltreatment experiences and positive reappraisal abilities were measured using the Childhood Trauma Questionnaire-Short Form and the Cognitive Emotion Regulation Questionnaire, respectively. Twelve subjects reported one or more moderate maltreatment experiences. Subjects were re-exposed to pictures after the cognitive reappraisal task using the International Affective Picture System during fMRI scan. Results The maltreatment group reported more negative feelings on negative pictures which tried cognitive reappraisal than the no-maltreatment group (p < 0.05). Activities in the right superior marginal gyrus and right middle temporal gyrus were higher in the maltreatment group (uncorrected p < 0.001, cluster size > 20). Conclusions We found that paradoxical activities in semantic networks were shown in the victims of maltreatment. Further study might be needed to clarify these aberrant functions in semantic networks related to maltreatment experiences.

Behavioral responses to cow and calf separation: separation at 1 and 100 days after birth

  • Sarah E. Mac;Sabrina Lomax;Cameron E. F. Clark
    • Animal Bioscience
    • /
    • 제36권5호
    • /
    • pp.810-817
    • /
    • 2023
  • Objective: The aim was to compare the behavioral response to full separation of cows and calves maintained together for 100 days or 24 h. Methods: Twelve Holstein-Friesian cow-calf pairs were enrolled into either treatment or industry groups (n = 6 cow-calf pairs/group). The treatment cows and calves were maintained on pasture together for 106±8.6 d and temporarily separated twice a day for milking. The Industry cows and their calves, were separated within 24 h postpartum. Triaxial accelerometer neck-mounted sensors were fitted to cows 3 weeks before separation to measure hourly rumination and activity. Before separation, cow and calf behavior was observed by scan sampling for 15 min. During the separation process, frequency of vocalizations and turn arounds were recorded. At separation, cows were moved to an observation pen where behavior was recorded for 3 d. A CCTV camera was used to record video footage of cows within the observation pens and behavior was documented from the videos in 15 min intervals across the 3 d. Results: Before separation, industry calves were more likely to be near their mother than Treatment calves. During the separation process, vocalization and turn around behavior was similar between groups. After full separation, treatment cows vocalized three times more than industry cows. However, the frequency of time spent close to barrier, standing, lying, walking, and eating were similar between industry and treatment cows. Treatment cows had greater rumination duration, and were more active, than industry cows. Conclusion: These findings suggest a similar behavioral response to full calf separation and greater occurrence of vocalizations, from cows maintained in a long-term, pasture-based, cow-calf rearing system when ompared to cows separated within 24 h. However, further work is required to assess the impact of full separation on calf behavior.

Evaluation of genetic differentiation and search for candidate genes for reproductive traits in pigs

  • Elena Romanets;Siroj Bakoev;Timofey Romanets;Maria Kolosova;Anatoly Kolosov;Faridun Bakoev;Olga Tretiakova;Alexander Usatov;Lyubov Getmantseva
    • Animal Bioscience
    • /
    • 제37권5호
    • /
    • pp.832-838
    • /
    • 2024
  • Objective: The use of molecular genetic methods in pig breeding can significantly increase the efficiency of breeding and breeding work. We applied the Fst (fixsacion index) method, the main focus of the work was on the search for common options related to the number of born piglets and the weight of born piglets, since today the urgent task is to prevent a decrease in the weight of piglets at birth while maintaining high fertility of sows. Methods: One approach is to scan the genome, followed by an assessment of Fst and identification of selectively selected regions. We chose Large White sows (n = 237) with the same conditions of keeping and feeding. The data were collected from the sows across three farrowing. For genotyping, we used GeneSeek GGP Porcine HD Genomic Profiler v1, which included 68,516 single nucleotide polymorphisms evenly distributed with an average spacing of 25 kb (Illumina Inc, San Diego, CA, USA). Results: Based on the results of the Fst analysis, 724 variants representing selection signals for the signs BALWT, BALWT1, NBA, and TNB (weight of piglets born alive, average weight of the 1st piglets born alive, total number born alive, total number born). At the same time, 18 common variants have been identified that are potential markers for both the number of piglets at birth and the weight of piglets at birth, which is extremely important for breeding work to improve reproductive characteristics in sows. Conclusion: Our work resulted in identification of variants associated with the reproductive characteristics of pigs. Moreover, we identified, variants which are potential markers for both the number of piglets at birth and the weight of piglets at birth, which is extremely important for breeding work to improve reproductive performance in sows.

Classification of Aβ State From Brain Amyloid PET Images Using Machine Learning Algorithm

  • Chanda Simfukwe;Reeree Lee;Young Chul Youn;Alzheimer’s Disease and Related Dementias in Zambia (ADDIZ) Group
    • 대한치매학회지
    • /
    • 제22권2호
    • /
    • pp.61-68
    • /
    • 2023
  • Background and Purpose: Analyzing brain amyloid positron emission tomography (PET) images to access the occurrence of β-amyloid (Aβ) deposition in Alzheimer's patients requires much time and effort from physicians, while the variation of each interpreter may differ. For these reasons, a machine learning model was developed using a convolutional neural network (CNN) as an objective decision to classify the Aβ positive and Aβ negative status from brain amyloid PET images. Methods: A total of 7,344 PET images of 144 subjects were used in this study. The 18F-florbetaben PET was administered to all participants, and the criteria for differentiating Aβ positive and Aβ negative state was based on brain amyloid plaque load score (BAPL) that depended on the visual assessment of PET images by the physicians. We applied the CNN algorithm trained in batches of 51 PET images per subject directory from 2 classes: Aβ positive and Aβ negative states, based on the BAPL scores. Results: The binary classification of the model average performance matrices was evaluated after 40 epochs of three trials based on test datasets. The model accuracy for classifying Aβ positivity and Aβ negativity was (95.00±0.02) in the test dataset. The sensitivity and specificity were (96.00±0.02) and (94.00±0.02), respectively, with an area under the curve of (87.00±0.03). Conclusions: Based on this study, the designed CNN model has the potential to be used clinically to screen amyloid PET images.

$^{99m}Tc$-diethylenetriaminepentaacetic acid 캅토프릴 신장스캔의 단측 신동맥 협착에 의한 신혈관성고혈압 진단 기준 (Diagnostic Criteria of $^{99m}Tc$-diethylenetriaminepentaacetic acid Captopril Renal Scan for the Diagnosis of Renovascular Hypertension by Unilateral Renal Artery Stenosis)

  • 최승진;홍일기;장재원;박수길;문대혁
    • 대한핵의학회지
    • /
    • 제38권6호
    • /
    • pp.498-505
    • /
    • 2004
  • 목적: 신혈관성고혈압의 진단에서 캅토프릴 투여후 $^{99m}Tc$-DTPA 신기능곡선 및 신기능의 기준 별로 비교된 바 없다. 이 연구는 단측 신동맥협착에 의한 신혈관성고혈압에서 캅토프릴 스캔의 진단 기준별 성적을 비교함이었다. 대상 및 방법: 1995년 5월에서 2004년 5월까지 신혈관성고혈압이 의심되어 캡토프릴신장스캔과 신혈관조영술을 시행한 64명 중 신혈관협착 있어서(n=51), 혈관재성형술을 받은 37명 중 양측성 신혈관협착 13명을 제외한 24명을 대상으로 하였다. 동맥경화가 14예, 섬유근성이형성증이 4명, 기타 혈관염이 6명이었다. 캅토프릴 및 기저 스캔은 The Society of Nuclear Medicine의 표준화된 지침에 의하여, 신기능곡선(5등급) 및 상대적 신기능, 협착이 있는 신장의 캅토프릴과 기저 스캔의 신기능곡선의 등급차이(CBren), 신기능의 차이(BCfun) 및 캅토프릴스캔시 반대측 신기능곡선과의 등급 간의 차이(CNren) 를 구하였다. 결과: 24명(남/여=16/8, 나이 $39.2{\pm}18.4$세)중 8명이 완치, 11명이 호전되어 신혈관성고혈압으로 진단되었고, 5명이 혈압의 변화가 없었다. 신혈관성고혈압과 본태성고혈압군 간에 나이(median 30 vs. 52; p<0.05), 원인(동맥 경화/기타: 9/10 vs. 5/0, p<0.05), CBren (median 2.5 vs. 0; p<0.005), BCfun (median 4 vs -0.5; p<0.05), CNren (median 2 vs. 0; p<0.05)의 유의한 차이가 있었다. 성별, creatinine과 기저 및 캅토프릴시 신기능은 차이가 없었다. 수신자판단특성곡선하의 면적은 나이 0.826, CBren 0.929, BCfun 0.804, CNren 0.784로 곡선하의 면적은 유의한 차이가 없었다. 양성 및 음성예측도는 나이 38세 이하의 기준으로 100%(12/12), 42%(5/l2), BCfun 1% 이상 92%(11/12), 50%(3/6), CBren 1이상 92%(13/14), 75%(3/4), CNren 1이상 90% (17/19), 60% (3/5)였다. 유용한 진단기준으로 알려진 BCfun 5% 이상은 100%(4/4), 29%(4/14)였다. 결론: 캅토프릴스캔에서 신기능곡선과 신기능 모두 유용한 신혈관성고혈압의 기준이 되며, 신기능곡선은 기저스캔과의 비교없이도 정상 신장의 신기능곡선을 비교하여 신혈관성고혈압을 진단할 수 있다.

PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가 (Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image)

  • 박선명;이혁;홍건철;정은경;최춘기;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.41-46
    • /
    • 2011
  • 영상장치를 이용한 검사 시 영상의 질은 검사결과와 밀접하게 연관되어 있으며, 이는 영상획득 조건들과 이에 대한 평가방법으로 인해 달라 질 수 있다. 본 연구에서는 영상획득 시 사전설정법(Pre-set method)차이에 따른 영상의 질을 평가하였다. 장비는 PET/CT Discovery STe16(GE Healthcare, Milwaukee, USA)을 사용하였으며, Chest PET Phantom (실험 1)과 94 NEMA Phantom (실험 2)을 이용하였다. 실험 1의 경우 3.5, 6.0, 8.6 kBq/mL, 실험 2의 경우는 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL의 $^{18}F$-FDG를 채웠고, 열소와 배후방사능과의 방사능 농도는 4:1의 비율을 유지하였다. 각 실험은 CT 투과촬영 후 3D로 2분 30초/프레임으로 시간설정법(Time-set method)과 1억 계수의 계수설정법 (Count-set method)을 적용하여 방출촬영 하였다. 영상의 질에 대한 평가는 잡음 등가 계수율 (Noise Equivalent Count Rate, NECR)과 신호 대 잡음비 (Signal to Noise Ratio, SNR)를 이용하였다. 실험 1에서 NECR과 SNR은 방사능 농도의 증가에 따라 시간설정법에서 53.7, 66.9, 91.4 과 7.9, 10.0, 11.7로 평가 모두에서 증가함을 보였으나, 계수설정법은 53.8, 69.1, 97.8과 14.1, 14.7, 14.4로 SNR은 NECR과 다르게 증감현상을 보이지 않았다. 또 다른 모형실험인 실험 2에서도 NECR과 SNR은 방사능 농도가 증가에 따라 시간설정법에서 45.1, 70.6, 95.3 115.6 134.6 162.2 과 7.1, 8.8, 10.6, 11.5, 12.7, 14.0으로 증가함을 보였으나, 계수설정법에서는 42.1 67.3 92.1 112.2 130.7 158.7 과 15.2, 15.9, 15.6, 15.4, 15.5, 14.9로 실험 1에서와 마찬가지로 SNR에서는 증감현상을 보이지 않았다. 사전설정법 변화와 관계없이 단위 질량당 방사능량 증가는 영상의 질도 비례하여 향상된다. 그러나 동일한 단위 질량당 방사능량에서는 영상획득의 시간을 늘려 총계수값을 증가시켜도 NECR에 영향을 주지는 않는다. 이는 NECR을 이용한 영상 질 평가는 영상획득 시 얻은 총 계수 값보다는 단위 시간당의 계수율이 영향을 준다는 것을 의미한다고 할 수 있다. 실험 모두에서 계수설정법으로 얻은 경우에는 단위 질량당 방사능량의 증가에도 불구하고 거의 비슷한 SNR값을 보이게 된다. 따라서 좋은 질의 영상을 얻기 위해서는 총 계수값의 증가보다는 단위질량당 방사능량을 높여야 하며, SNR만을 이용한 영상의 질에 대한 평가는 적절하지 않을 수 있다는 점을 고려하여야 한다.

  • PDF

CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석 (Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs)

  • 김정선;정우영;박승용
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.77-82
    • /
    • 2010
  • PET/CT 기기의 설치가 증가함에 따라 PET/CT 검사 시감쇄 보정을 위한 CT 검사 역시 증가하여 검사 과정에서 피폭 선량이 증가 되고 있어 의료 피폭의 저감 대책을 포함한 방사선 안전 관리의 체계적인 구축이 필요하다. 본 연구에서는 PET/CT 검사에서의 환자 선량 데이터베이스를 구축하여 환자 선량 저감을 위한 초석을 세우기 위해 CT 선량 측정 프로그램을 사용하여 CT를 사용한 투과 스캔 시 환자가 받는 CT의 예측 유효 선량을 비교 분석하였다. BIO40, BIO16, DSTe8 에서 $^{18}F$-FDG PET/CT 검사를 시행한 180명을 대상으로 하였다. 각 기기 별로 남, 여 30명씩 선량의 평균을 분석하였다. 자동 노출 제어 시스템으로 선량 조절 시 가장 큰 영향을 줄 수 있는 환자의 체중 별로 50 kg미만, 50-60 kg 미만, 60 kg 이상 세 집단으로 나누어 선량의 평균을 분석하였다. CT-Expo v1.7과 ImPACT v1.0을 사용하여 선량 측정을 한 값을 비교 분석하고 체중과 유효 선량의 상관관계를 분석하였다. BIO40에서 검사한 환자의 유효 선량을 CT-Expo v1.7과 ImPACT v1.0을 사용하여 예측하였을 때, 남자 환자 30명은 각각 $6.46{\pm}1.18$ mSv, $6.54{\pm}1.21$ mSv, 여자 환자 30명은 각각 $6.29{\pm}0.97$ mSv, $5.87{\pm}1.09$ mSv 이었다. BIO16 에서 검사한 환자의 유효 선량은 남자 환자 30명은 각각 $9.36{\pm}1.96$ mSv, $8.36{\pm}1.69$ mSv 여자 환자 30명은 각각 $10.02{\pm}2.42$ mSv, $8.43{\pm}1.89$ mSv 이었다. DSTe8에서 검사한 환자의 유효 선량은 남자 환자 30명은 각각 $9.36{\pm}1.96$ mSv, $9.74{\pm}2.55$ mSv, 여자 환자 30명은 각각 $9.05{\pm}2.27$ mSv, $9.19{\pm}2.29$ mSv 이었다. 각 기기에서 검사를 시행한 환자의 체중에 따른 환자의 선량을 비교하기 위해, BIO40에서 검사를 시행한 환자를 대상으로 하여 50 kg 미만, 50~60 kg 미만, 60 kg 이상으로 체중별로 세 개의 집단으로 나누어 환자 선량을 측정하였다. CT-expo v1.7로 측정을 하였을 때 각각 $6.05{\pm}1.77$ mSv, $6.18{\pm}1.05$ mSv, $6.80{\pm}1.06$ mSv이었고 ImPACT v1.0으로 측정했을 때 각각 $5.06{\pm}1.46$ mSv, $5.72{\pm}0.86$ mSv, $6.42{\pm}0.96$ mSv이었다. BIO16에서 검사를 시행한 환자를 대상으로 하여 50 kg 미만, 50-60 kg 미만, 60 kg 이상으로 체중 별로 나누어 환자 선량을 측정하였다. CT-Expo v1.7로 측정을 하였을 때 각각 $7.74{\pm}0.66$ mSv, $8.58{\pm}0.93$ mSv, $10.88{\pm}1.32$ mSv이었고 ImPACT v1.0으로 측정했을 때 각각 $6.60{\pm}0.54$ mSv, $7.45{\pm}0.69$ mSv, $9.43{\pm}1.11$ mSv이었다. DSTe8에서 검사를 시행한 환자를 대상으로 하여 50 kg 미만, 50-60 kg 미만, 60kg 이상으로 체중 별로 나누어 환자 선량을 예측하였다. CT-Expo v1.7로 측정했을 때 각각 $5.03{\pm}0.95$ mSv, $8.25{\pm}1.66$ mSv, $10.33{\pm}1.68$ mSv 이었고 ImPACT v1.0으로 측정했을 때 각각 $5.20{\pm}1.01$ mSv, $8.51{\pm}1.53$ mSv, $10.9{\pm}1.87$ mSv이었다. 체중과 유효 선량의 상관관계를 분석하였을 때 CT-Expo v1.7과 ImPACT v1.0에서 Pearson 정률 상관계수가 각각 0.743, 0.692으로 매우 강한 양의 상관관계가 있었다. 피폭 선량의 예측이 필요할 경우 이와 같은 상용화된 선량 평가 프로그램을 사용하면 Phantom 연구를 시행하지 않더라도 유효 선량의 예측 및 평가가 가능하고, CT 선량 관리를 위한 기초 자료를 수집하는데 활용 될 수 있을 것으로 생각된다.

  • PDF

PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가 (Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners)

  • 박승용;고현수;김정선;정우영
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.47-52
    • /
    • 2011
  • PET/CT 검사의 자료 저장 및 분석을 위해 장비 자체의 workstation과는 별도로 자체 서버를 이용하거나 mini PACS를 구비하여 운영하기도 한다. mini PACS는 검사 자료의 저장뿐만 아니라 각 회사의 PET/CT 장비에서만 측정할 수 있었던 표준섭취계수(standardized uptake value, 이하 SUV)를 PACS 상에서도 측정이 가능하도록 개발되어 있다. 이에 PET/CT 장비 별 측정 된 SUV가 mini PACS에서도 동일하게 측정되는지 파악하기 위해 본 논문을 쓰게 되었다. 본원에 설치 된 Siemens사의 Biograph 16, Biograph 40 장비와 GE사의Discovery Ste 8 장비에서 각각 2011년 2월에 $^{18}F$-FDG 전신 PET 검사를 시행한 환자 30명의 liver와 mediastinum 높이에서 aorta의 SUV를 측정하고, mini PACS 프로그램에서도 같은 위상의 영상에서 SUV를 측정하여 분석하였다. PET/CT 장비와 mini PACS의 SUV의 상관계수는, Liver에서 Biograph 16은 0.99, Biograph 40은 0.98, Discovery Ste은 8 0.64이었고, aorta에서 Biograph 16은 0.98, Biograph 40은 0.98, Discovery Ste은 8 0.66이었으며 모두 양의 상관 관계가 있었다. Biograph 16에서의 liver와 aorta의 평균 SUV는 각각 $1.65{\pm}0.21g/mL$, $1.09{\pm}0.13g/mL$이었고, mini PACS에서는 $1.65{\pm}0.21g/mL$, $1.08{\pm}0.14g/mL$이었다. Biograph 40에서는 $1.82{\pm}0.30g/mL$, $1.31{\pm}0.21g/mL$, mini PACS에서는 $1.82{\pm}0.29g/mL$, $1.32{\pm}0.21g/mL$이었다. Biograph 장비와 mini PACS의 SUV는 유의수준 0.05에서 통계적으로 유의한 차이가 없었다. Discovery Ste 8에서는 liver와 aorta의 평균 SUV가 $1.48{\pm}0.15g/mL$, $0.96{\pm}0.12g/mL$, mini PACS에서는 $1.67{\pm}0.18g/mL$, $1.16{\pm}0.13g/mL$이었고, 유의수준 0.05에서 통계적으로 유의한 차이가 있었다. Biograph 16, Biograph 40, Discovery Ste 8 세 장비 모두 SUV 측정에서 mini PACS와 높은 상관관계가 있었고, 특히 mini PACS에서 측정한 Biograph 장비들의 SUV는 차이가 없었다. 다만 mini PACS와 Discovery Ste 8에서 측정된 SUV는 liver에서는 $0.19{\pm}0.03g/mL$, aorta에서는 $0.20{\pm}0.01g/mL$로 mini PACS 값이 높게 측정되었고, 통계적으로도 차이가 있었지만 그 차이는 미세하였다. 장비 별 mini PACS의 SUV 계산식에 대한 보완이 이루어진다면, 동일 환자가 다른 장비에서 검사한 경우 이와 같은 mini PACS 시스템을 이용한 분석을 통해, 추적 검사를 수행하는 환자의 일관성 있는 정량분석 자료를 제공할 수 있을 것으로 판단된다.

  • PDF

Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가 (Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study)

  • 도용호;이홍재;김진의;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.15-22
    • /
    • 2018
  • PET/MRI 검사 시 호흡에 의한 움직임은 영상의 질 저하는 물론 종양의 크기, 표준섭취계수의 오차를 발생시키는 원인이 된다. 본 연구에서는 일체형 PET/MRI 장비에서 MR기반 호흡 움직임 보정 방법의 적용에 따른 종양의 표준섭취계수, 크기와 영상 품질 변화를 평가하고자 하였다. Biograph mMR 3.0T (Siemens, Germany)장비에서 2016년 3월부터 7월까지 $^{18}F-FDG$ liver PET/MRI 검사를 시행한 30명 ($62.5{\pm}10.2$세)의 데이터를 분석하였다. 7분의 PET listmode 데이터를 획득하는 동안 MR 기반 호흡 움직임 보정 방법인 MAG, MTG와 NG T1 weighted MR 영상을 획득하였다. Gated PET 영상의 재구성은 35% efficiency window가 적용된 MAG와 MTG로부터 획득된 감쇄보정영상을 이용하여 시행하였다. Non-gate, MAG, MTG 영상에서 측정된 종양의 표준섭취계수와 Z축 방향의 크기 그리고 반치폭을 분석하였다 평균 $SUV_{max}$$SUV_{peak}$는 NG 대비 MAG 13.15%(P<0.0001), 8.66%(P<0.0001), MTG 13.27%(P<0.0001), 8.80%(P<0.0001) 증가하였으며 Z-축에서 평균 종양의 크기와 반치폭은 MAG 14.47%(P<0.0001), 15.49%(P=0.0004), MTG 14.89%(P<0.0001), 15.79%(P=0.0003) 감소하였으며 통계적으로 유의한 차이를 보였다. MAG와 MTG 비교 평가에서 MTG의 $SUV_{max}$$SUV_{peak}$는 MAG 대비 0.07%(P=0.8802), 0.13%(P=0.7766) 증가하였으며 Z-축에서 평균 종양의 크기와 반치폭은 0.49%(P=0.2786), 0.36%(P=0.2488) 감소하였다. 약 7분과 2분의 추가 검사시간이 필요한 MAG와 MTG에서 표준섭취계수와 종양의 크기, 반치폭에서 통계적으로 유의한 차이가 없었다. 간 PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법을 적용하였을 때 NG 대비 MAG, MTG 모두에서 표준섭취계수와 종양의 크기 및 공간분해능이 개선되었으며 MAG와 MTG의 결과 값은 통계적으로 유의한 차이가 없었다. 호흡에 의한 움직임에 영향을 받는 다양한 상 복부 검사에 MBRMCT를 적용 시 추가적인 장비의 설치 없이 약 2분의 추가 검사시간이 필요한 MTG 방법 적용하여 NG 대비 보다 정확한 정보를 제공할 수 있을 것으로 사료된다.