• Title/Summary/Keyword: F- anion

Search Result 15, Processing Time 0.025 seconds

A Calix[4]pyrrole Bearing a Quaternary Ammonium Group: A Fluoride-Selective Anion Receptor

  • Oh, Ju Hyun;Lee, Joon Hwa;Kim, Sung Kuk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.25 no.4
    • /
    • pp.45-50
    • /
    • 2021
  • A calix[4]pyrrole (1) bearing a quaternary ammonium pendant via its meso phenoxy linker has been synthesized as the bromide salt form. It was revealed by 1H NMR spectroscopic analyses performed in DMSO-d6 that receptor 1 binds F- with high affinity and selectivity over other halide anions. The binding of receptor 1•Br- with F- and Cltakes place by anion metathesis with the anions including F- and Cl-.

Characteristics of Selectivity in Anion Exchanges (음이온 선택도 특성)

  • 이석중;안현경;이인형
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.3
    • /
    • pp.194-197
    • /
    • 2002
  • Ion exchange is a chemical reaction between the ions in solution phase and ions in solid phase and is widely used in softening, demineralization, removal and collection of specific ions, and ion migration in the ground water. The ion selectivity depends on the charge and the hydrated radius of ion. The objective of this study was to examine the applicability of anion selectivity obtained from the ion exchange equilibrium OH/sup -/ < F/sup -/ < HCO/sup -/ < Cl/sup -/ < Br/sup -/ ≤ NO₃/sup -/ < SO₄/sup 2-/ to the column ion exchange. The column ion exchange was facilitated in the lower charge of counter-ion in the background electrolyte.

  • PDF

Selectivity Characteristics for Equilibrium and Column Anion Exchanges (음이온 평형 및 칼럼교환 선택도 특성)

  • 이인형;이석중
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.137-139
    • /
    • 2002
  • 이온교환은 액체상 이온과 고체상 이온간의 화학반응이며 연수 및 탈염공정, 특정물질의 제거 및 회수, 토양을 통한 이온성 물질의 이동에서 널리 이용되고 있다. 이온교환수지는 이온교환시 원자가가 높을수록, 수화반경이 작을수록, 이온농도가 낮을수록 증가한다. 본 연구는 이온교환수지에 대한 평형실험을 선택도가 칼럼실험에 적용되는지 조사하였다. 이 실험치 결과에서 음이온 교환수지의 선택도 순서는 OH/sup -/ < F/sup -/ < HCO₃/sup -/ < Cl/sup -/ < Br/sup -/ ≤ No₃/sup -/ < So₄/sup 2-/ 이였으며, 음이온 칼럼 교환도 동일하였다. 또한 바탕 양이온의 가수가 높을수록 이온교환이 빠르게 진행됨을 알 수 있다.

Electrochemical Method for Measurement of Hydroxide Ion Conductivity and CO2 Poisoning Behavior of Anion Exchange Membrane (음이온 교환막의 정확한 OH-전도도 및 CO2 피독 효과 분석을 위한 전기화학적 측정법)

  • Kim, Suyeon;Kwon, Hugeun;Lee, Hyejin;Jung, Namgee;Bae, Byungchan;Shin, Dongwon
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2022
  • The anion exchange membrane used in alkaline membrane fuel cells transports hydroxide ions, and ion conductivity affects fuel cell performance. Thus, the measurement of absolute hydroxide ion conductivity is essential. However, it is challenging to accurately measure hydroxide ion conductivity since hydroxide ions are easily poisoned in the form of bicarbonate by carbon dioxide in the atmosphere. In this study, we applied electrochemical ion exchange treatment to measure the absolute hydroxide ion conductivity of the anion exchange membrane. In addition, we investigated the effect of carbon dioxide poisoning of hydroxide ions on electrochemical performance by measuring bicarbonate conductivity. Commercial anion exchange membranes (FAA-3-50 and Orion TM1) and polyphenylene-based block copolymer (QPP-6F) were used.

The Study on the Ion Water Characteristics of Raw Water in the Domestic Natural Mineral Water (국내 유통 중인 먹는샘물 원수의 이온류 수질 특성에 관한 연구)

  • Lee, Leenae;Ahn, Kyunghee;Min, Byungdae;Yang, Mihee;Choi, Incheol;Chung, Hyenmi;Park, Juhyun
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.5
    • /
    • pp.442-449
    • /
    • 2016
  • The goal of this study is to provide basic data to establish a foundation for the provision of safe drinkable water. The raw water of natural mineral water was analyzed to determine the quantities of anions (F-, Cl-, NO3-N-, and SO42- ) and cations (Ca2+, K+, Mg2+, and Na+) during the former and latter half of 2016. Analysis of the current quality of the raw water of natural mineral water among domestic manufacturers showed average anions contents of 0.46mg/L of fluorine, 8mg/L of chlorine ion, 1.5mg/L of nitrate nitrogen, and 12mg/L of sulfate ion. While the fluorine content was greater than the water quality criterion of 2.0mg/L at four points, the fluorine level was overall stable. The average cations contents included 21.3mg/L of calcium, 1.0mg/L of potassium, 3.4mg/L of magnesium, and 9.6mg/L of sodium. The chemical characteristics were compared among the major ions, and the results are presented in a piper diagram. The content ratio of cations was in the order of Ca2+> Na+>Mg2+>K+, whereas that of anions was in the order of SO42->Cl->NO3-N->F-. While the cations were slightly scattered, the anions were generally concentrated except for at a few points. The Ca-Na-HCO3 type was dominant overall in water sources from diorite, gneiss, and granite, while the Na-Mg-Ca-HCO3-Cl type was dominant in basalt sources. Mineral water manufacturers source their water under various conditions, including in-hole casing, excavation depth, and contact state of bedrock; even within the same rocky area, some differences in the water quality type can occur. When the depth of the water source was taken into account, the mean anions contents of F-, Cl-, NO3-N-, and SO42- were similar, with no significant differences according to depth. Of the cations, K+ and Na+ showed no significant differences across all the tubular wells, whereas Ca2+ and Mg2+ decreased in content with depth.

Theoretical Investigation of the Hydrogen-bonded Halide-acetylene Anion Complexes

  • Byeong-Seo Cheong
    • Journal of the Korean Chemical Society
    • /
    • v.68 no.2
    • /
    • pp.65-73
    • /
    • 2024
  • The halide-acetylene anions, X--HCCH (X = F, Cl, and Br) have been studied by using several different ab initio and DFT methods to determine structures, hydrogen-bond energies, vibrational frequencies of the anion complexes. Although the halide-acetylene complexes all have linear equilibrium structures, it is found that the fluoride complex is characterized with distinctively different structure and interactions compared to those of the chloride and bromide complexes. The performance of various density functionals on describing ionic hydrogen-bonded complexes is assessed by examining statistical deviations with respect to high level ab initio CCSD(T) results as reference. The density functionals employed in the present work show considerably varying degrees of performance depending on the properties computed. The performances of each density functional on geometrical parameters related with the hydrogen bond, hydrogen-bond energies, and scaled harmonic frequencies of the anion complexes are examined and discussed based on the statistical deviations.

Fast and Easy Drying Method for the Preparation of Activated [18F]Fluoride Using Polymer Cartridge

  • Seo, Jai-Woong;Lee, Byoung-Se;Lee, Sang-Ju;Oh, Seung-Jun;Chi, Dae-Yoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.71-76
    • /
    • 2011
  • An efficient nucleophilic [$^{18}F$]fluorination has been studied to reduce byproducts and preparation time. Instead of conventional aqueous solution of $K_2CO_3-K_{222}$, several organic solution containing inert organic salts were used to release [$^{18}F$]fluoride ion and anion bases captured in the polymer cartridge, concluding that methanol solution is the best choice. Comparing to azeotropic drying process, one min was sufficient to remove methanol completely, resulting in about 10% radioactivity saving by reducing drying time. The polymer cartridge, Chromafix$^{(R)}$ (PS-$HCO_3$) was pretreated with several anion bases to displace pre-loaded bicarbonate base. Phosphate bases showed better results than carbonate bases in terms of lower basicity. tert-Butanol solvent used as a reaction media played another critical role in nucleophilic [18F]fluorination by suppressing eliminated side product. Consequent [$^{18}F$]fluorination under the present condition afforded fast preparation of reaction solution and high radiochemical yields (98% radio-TLC, 84% RCY) with 94% of precursor remained.

High Yielding [18F]Fluorination Method by Fine Control of the Base

  • Lee, Sang-Ju;Oh, Seung-Jun;Chi, Dae-Yoon;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2177-2180
    • /
    • 2012
  • New [$^{18}F$]F-fluorination methods using a minimized amount of precursor has been developed by controlling the base concentration. In the first method, pre-conditioning of the anion exchange cartridge with $K_2CO_3$ solution or water was carried out. The trapped [$^{18}F$]fluoride on the cartridge was then eluted by KOMs or KOTf solution. [$^{18}F$]F-Fluorination could be performed without additional base. In the second method, the QMA cartridge was preconditioned with KOMs solutions. Trapped [$^{18}F$]fluoride on the QMA was then eluted with KOMs and additional base, such as KOH, $K_2CO_3$, and $KHCO_3$, was added into the reaction vessel. Method 1 showed a [$^{18}F$]F-incorporation yield of 20.9% for [$^{18}F$]FLT synthesis with 5 mg of precursor. Unlike method 1, a [$^{18}F$]F-incorporation yield of 91.4% was achieved from the same amount of precursor in method 2.

Optimization of solid phase extraction and simultaneous determination of trace anions in concentrated hydrofluoric acid by ion chromatography (불산 중 극미량 음이온 분석을 위한 고상 추출법 및 이온크로마토그래프를 이용한 동시분석법 확립)

  • Yoon, Suk-Hwan;Jo, Dong-ho;Kim, Hyun-Ji;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.219-224
    • /
    • 2016
  • 불산 중 극미량 음이온의 고상추출과 이온크로마토그래프를 이용한 고감도 분석법이 개발되었다. 불산 중 불소이온이 고상에 의해 제거하였고 이어서 음이온 (F, CH3COO, Cl, Br, NO3, PO43−, SO42−)들이 이온크로마토그래프를 이용하여 연속적으로 분리하였다. 고상 추출법에 영향을 주는 각 인자들 (흡착제의 선택, 시료의 부피 및 pH, 용출 용액과 용출용액의 부피)을 결정하였으며 그 결과 흡착제로서 Oasis WAX 컬럼이 가장 우수하였고 1.0 mL의 시료부피, 용출용액으로 50 mM 초산암모늄염 5 mL가 분리능에서 가장 우수하였다. 개발한 방법에 의한 음이온 (Cl, Br, NO3, PO43−, SO42−)들의 방법검출한계는 25 % 불산용액 (w/w) 중에 0.04~0.30 µg/L의 범위를 보였고 정밀도는 20.0와 40.0 µg/L의 농도에서 5 % 이내를 보였다. 한 제조회사에 의한 25 % 불산 중 음이온의 4.2에서 47.5 µg/L의 범위로 모두 검출되었다. 이 방법은 시험절차가 간단하고, 재현성 및 감도가 좋아서 반도체회사에서 불산 중 음이온 불순물을 정도 관리하는데 매우 유용한 방법이 될 것으로 판단된다.