• Title/Summary/Keyword: Eyes

Search Result 2,547, Processing Time 0.029 seconds

The impact of joint mobilization with an elastic taping on immediate standing balance in patients with knee osteoarthritis. (무릎 관절염 환자에 대한 관절가동술과 탄력 테이핑 융복합 적용이 즉각적인 기립 균형에 미치는 영향)

  • Park, Shin-Jun;Kim, Dong-Dae
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.295-304
    • /
    • 2017
  • The purpose of this study was to identify the immediate effect of the joint mobilization with an elastic taping on standing balance in patients with knee osteoarthritis. Thirty patients with knee osteoarthritis were randomly divided into three groups: a taping group, a joint mobilization group, and a joint mobilization with taping group. A foot pressure platform (Zebris) was used to evaluate standing balance ability, and the sway area, path length and average velocity were measured during eyes open condition and eyes closed condition. All the groups showed a significant improvement in the sway area during eyes closed condition after intervention, and the joint mobilization with taping group revealed significant improvements in the path length and average velocity. There was no significant difference in the standing balance ability among all the groups. Both the joint mobilization and taping method were effective methods for standing balance during eyes closed condition, and it has been found that the convergence of the two interventions had an effect on diverse balance variables. Thus, it is recommended to apply the convergence of the two interventions for patients with knee osteoarthritis.

A Driver's Condition Warning System using Eye Aspect Ratio (눈 영상비를 이용한 운전자 상태 경고 시스템)

  • Shin, Moon-Chang;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.349-356
    • /
    • 2020
  • This paper introduces the implementation of a driver's condition warning system using eye aspect ratio to prevent a car accident. The proposed driver's condition warning system using eye aspect ratio consists of a camera, that is required to detect eyes, the Raspberrypie that processes information on eyes from the camera, buzzer and vibrator, that are required to warn the driver. In order to detect and recognize driver's eyes, the histogram of oriented gradients and face landmark estimation based on deep-learning are used. Initially the system calculates the eye aspect ratio of the driver from 6 coordinates around the eye and then gets each eye aspect ratio values when the eyes are opened and closed. These two different eye aspect ratio values are used to calculate the threshold value that is necessary to determine the eye state. Because the threshold value is adaptively determined according to the driver's eye aspect ratio, the system can use the optimal threshold value to determine the driver's condition. In addition, the system synthesizes an input image from the gray-scaled and LAB model images to operate in low lighting conditions.

Experimental Proliferative Vitreoretinopathy (증식성 초자체망막증의 실험적 유발)

  • Park, Young-Hoon;Lee, Bong-Hwan;Hahn, Duk-Kee
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.178-190
    • /
    • 1991
  • The authors performed experimental study to produce proliferative vitreoretinopathy by intravitreal injection of homologous fibroblasts in pigmented rabbits. Twenty four eyes of 12 rabbits were divided into control and experimental groups. In experimental group, the eyes were pretreated with expanding gas, perfluoropropane for the vitrectomy. In control group, no such procedure was preceded. In both groups, $5.0{\times}10^4$, $1.0{\times}10^5$ and $1.5{\times}10^5$ cells of homologous fibroblasts were injected into the vitreous cavity. All the eyes were observed regularly with indirect ophthalmoscope followed by fundus photography. Those eyes were enucleated in 1, 2, 4 weeks for the light and electron microscopic studies. The development and severity of the proliferative vitreoretinopathy were correlated with the numbers of the injected fibroblast. This was more pronounced in the experimental group.

  • PDF

Evaluation of Balance Ability of the Elderly Using Kinect Sensor (키넥트 센서를 이용한 고령자 대상의 선자세 균형능력 평가)

  • Yang, Seung-Tae;Kang, Dong-Won;Seo, Jeong-Woo;Kim, Dae-Hyeok;Kim, Tae-Ho;Choi, Jin-Seung;Tack, Gye-Rae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.439-446
    • /
    • 2017
  • Portable low-cost Kinect sensor was used to analyze standing balance ability of the elderly. Eighty subjects who can walk alone and have a normal cognitive level participated in this experiment. Based on Berg Balance scale (BBS) test with 52 points, subjects were divided into Healthy older (HO: 46 persons, BBS: $53.80{\pm}1.19$) and Impaired older (IO: 34 persons, BBS: $49.06{\pm}2.03$) group. Each subject performed 30 seconds four different standing balance tests (EO: Eyes Open, EC: Eyes Close, EOf: Eyes Open on foam, ECf: Eyes Close on foam). Five variables (Mean distance, Range of distance, Root mean square, Mean velocity, 95% ellipse area) were calculated from the hip joint center movement of Kinect sensor. Results showed that there were significant differences between groups for four different standing tests. Calculated variables from kinect sensor showed significant correlation with BBS score. Especially, mediolateral mean distance, mediolateral root mean square, mediolateral range of distance and 95% ellipse area showed discriminative ability for all tests. Mean values of variables of IO were higher than those of HO, which means the decreased balance ability in IO compared with HO. Therefore, it was possible to estimate simple balance assessment of the elderly using portable low-cost Kinect sensor.

The Effects of the Upright Body Type Exercise Program on Body Balance and Record of Archers

  • Kim, Dong-Kuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.9-18
    • /
    • 2018
  • Objective: This study aimed to analyze how the upright body type exercise program affected body balance and record of archers. This study aimed to prove the effectiveness of upright body type exercise, on this basis, in enhancing the performance of archery players. Method: A total of 14 archers (7 men and 7 women) in B Metropolitan City who had ${\geq}4years$ of career in archery and were given explanation of its contents and purpose before giving spontaneous consent to the experiment were enrolled in the study. The upright body type exercise program was implemented thrice a week for 12 weeks, with higher exercise intensity with time. A resistive pressure sensor, Gaitview AFA-50, was used to measure the foot plantar pressure distribution and analyze quantitative information concerning variation in posture stability and weight shift in dynamic balance of foot plantar pressure in shooting and static balance of plantar pressure with the eyes open and closed and the change in archery record accompanying the change in body balance. Results: As for the differences in foot plantar pressure between before and after participation in the upright body type exercise program, there was no significant difference in static balance of foot plantar pressure with the eyes open, and there was statistically significant difference at the ${\alpha}=.05$ significance level in static balance of foot plantar pressure with the eyes closed or in dynamic balance of foot plantar pressure in shooting. There was statistically significant difference at the ${\alpha}=.05$ significance level in archery record. Conclusion: The upright body type exercise program had positive effects on static and dynamic balance of foot plantar pressure by allowing archers to experience less body sway and physical imbalance in shooting with closed eyes and positive effects on archery record. Thus, the program is expected to help archers correct their posture and perform better.

A study on the nine orifices -from horizontal and vertical views- (구규(九竅)에 대한 연구(硏究) -수평(水平)과 수직(垂直)의 관점을 위주로-)

  • Kang, Jung-Soo
    • Journal of Oriental Physiology
    • /
    • v.14 no.2 s.20
    • /
    • pp.11-21
    • /
    • 1999
  • In this paper the nine orifices were analyzed horizontally and vertically and the relationship between the upper seven orifices and lower two orifices was looked into specifically. The following results were obtained : l. Horizontal is the shenji (神機) which comes in and out, and it symbolizes animality based on heaven. so it is dynamic. Vertical is the qiji (氣機) which goes up and down. and it symbolizes vegetability based on earth. so it is static. 2. The shape of the eyes and lips is horizontal, so the shape of the liver and spleen which are related to the eyes and lips respectively is also horizontal. Thus the eyes and lips can move and the action of these are mainly concerned with the coming in and out of energy. 3. The shape of the nose and ears is vertical. so the shape of the lungs and kidneys which are related to the nose and ears respectively is also vertical. Thus the nose and ears remain still and the action of these are mainly concerned with going up and down of energy. 4. One means yang(陽) and two means yin(陰). so the nose and mouth which have one are yang. the eyes and ears which have two are yin. 5. The urethra consists of yangming(陽明) and taiyin(太陰) which control the front so it draws out urine which is yang(陽). The anus controls the back. so it draws out feces which is yin(陰). 6. The upper seven orifices are related to the five viscera which control immaterial spirit. The lower two orifices are related to the six bowels which control material movement.

  • PDF

Clinical Results of Anti-adhesion Adjuvants after Endonasal Dacryocystorhinostomy

  • Shin, Hye-Young;Paik, Ji-Sun;Yang, Suk-Woo
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.433-437
    • /
    • 2018
  • Purpose: Various absorbable anti-adhesion agents have been used to prevent postoperative synechia formation after endonasal surgery. The purpose of this study was to evaluate the anti-adhesion effects of HyFence and Mediclore after endonasal dacryocystorhinostomy (DCR) compared to a mixed solution of hyaluronic acid and sodium carboxymethylcellulose (Guardix-Sol). Methods: In this retrospective study, endonasal DCR and silicone tube intubation were performed on 198 eyes of 151 patients. Three different anti-adhesion adjuvants were applied to the osteotomy site in the nasal cavity after standard endonasal DCR procedures. The subjects were classified into three respective groups: group A (71 eyes, Guardix-Sol 1.5 g), group B (89 eyes, HyFence 1.5 mL), and group C (38 eyes, Mediclore 1 cc). The three groups were evaluated by asking patients about subjective symptoms and by performing lacrimal irrigation tests and endoscopic examinations. Results: There were no statistically significant differences in age, sex, timing of tube removal, or follow-up period among the three groups. There were no statistically significant differences in success rates among the three groups (p = 0.990, 91.5% [65 / 71], 92.1% [82 / 89], and 92.1% [35 / 38], respectively). Conclusions: HyFence and Mediclore are safe and effective adjunctive modalities following endonasal DCR compared to Guardix-Sol. Therefore, these agents can be considered good alternatives to Guardix-Sol to increase the success rate of endonasal DCR in treating patients with poor prognosis.

Eyes and Vision of the Bumblebee: a Brief Review on how Bumblebees Detect and Perceive Flowers

  • Meyer-Rochow, V.B.
    • Journal of Apiculture
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2019
  • Bumblebees have apposition compound eyes (one on either side of the head) of about 6,000 ommatidia and three small single-lens ocelli on the frons of their head capsule. The surface of the eye is smooth and interommatidial hairs, as in the honeybee, are not developed. Each ommatidium (approx. 26 ㎛ in diameter) is capped by a hexagonal facet and contains in its centre a 3 ㎛ wide, columnar light-perceiving structure known as the rhabdom. Rhabdoms consist of thousands of regularly aligned, fingerlike microvilli, which in their membranes contain the photopigment molecules. Axons from each ommatidium transmit the information of their photic environment to the visual centres of the brain, where behavioural reactions may be initiated. Since bumblebee eyes possess three classes of spectrally different sensitivity peaks in a ratio of 1:1:6 (UV= 353 nm, blue= 430 nm and green=548 nm) per ommatidium, they use colour vision to find and select flower types that yield pollen and nectar. Ommatidial acceptance angles of at least 3° are used by the bumblebees to discriminate between different flower shapes and sizes, but their ability to detect polarized light appears to be used only for navigational purposes. A flicker fusion frequency of around 110Hz helps the fast flying bumblebee to avoid obstacles. The small ocelli are strongly sensitive to ultraviolet radiation and green wavelengths and appear to act as sensors for light levels akin to a photometer. Unlike the bumblebee's compound eyes, the ocelli would, however, be incapable of forming a useful image.

Acute Effects of Dynamic Stretching and Self-Mobilization of the Ankle Joint on Dorsiflexion Range of Motion, Muscle Strength, and Balance in Healthy Adults

  • Kim, Kyoung-Han;Choi, Yun-Seo;Jeon, Jeongwoo;Hong, Jihoen;Yu, Jaeho;Kim, Jinseop;Kim, Seong-Gil;Lee, Dongyeop
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.63-72
    • /
    • 2022
  • Purpose : Several studies have investigated the effects of dynamic stretching (DS) and self-mobilization (SM), however, studies comparing the two interventions are rare. Therefore, the purpose of this study was to compare the effects of DS and SM on ankle strength, dorsiflexion range of motion (DFROM), and balance to determine which is superior. Methods : Thirty-two healthy young adults participated in this study. Participants were randomly assigned to two groups (SM and DS). DS was performed for the purpose of stretching the medial gastrocnemius muscle. For the SM group, ankle joint SM was performed in three ways. For all participants, the following measurements were performed as pre- and post-tests: isometric strength of dorsiflexor and plantar flexor, weight-bearing lunge test (WBLT) to evaluate DFROM, Tetrax system to evaluate static balance, and y balance test (YBT) to evaluate dynamic balance. Differences before and after the intervention within each group were compared using paired t-test. Also, the variable's variation was compared between groups using an independent t-test. Results : Significant differences were found in ankle dorsiflexor strength, WBLT, YBT, weight distribution index (WDI) (pillow and opened eyes; PO), and stability index (ST) (normal and closed eyes; NC) before and after intervention in the SM group (p<.05). In the DS group, significant differences were found in ankle dorsiflexor and plantar flexor strength, WBLT, YBT anterior, WDI (normal and opened eyes; NO, PO), and ST (NO, NC, PO, pillow and closed eyes) before and after the intervention (p<.05). Ankle plantar flexor strength and WDI (PO) were significantly different between groups. Conclusion : Based on the results of this study, DS or SM can be considered as a possibility for selective use according to variables for improving ankle joint function (DFROM, muscle strength, balance).

Effects of Elastic Taping and Non-elastic Taping on Static Balance Control Ability, Dynamic Balance Control Ability, and Navicular bone Drop in Young Adults

  • Lim, Jong-Gun;Lee, Hyun-Woo;Lee, Dongyeop;Hong, Ji-Heon;Yu, Jae-Ho;Kim, Jin-Seop;Kim, Seong-Gil
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.2
    • /
    • pp.1-10
    • /
    • 2022
  • PURPOSE: This study examined the effects of the low dye taping technique on the static and dynamic balancing ability and navicular bone drop when the low dye taping technique was divided into elastic and non-elastic taping. METHODS: The subjects of the study were 31 volunteers without musculoskeletal disorders. The length (L) and anterior (A), posteromedial, and posterolateral values of the arch in the NO (normal eyes open), NC (normal eyes closed), PO (pillow with eyes open), and PC (pillow with close eyes closed) states were evaluated when barefoot and when Kinesio tape and non-elastic tape were applied. The measurements were analyzed using repeated ANOVA and an independent t-test. Post hoc tests were performed using a Fisher's LSD. RESULTS: A significant difference was found in the arch L and A values using a foot scanner (p < .05). In addition, there was a significant difference in dynamic balance in the three directions (p < .05), and no difference was found in the case of static balance. As a result, non-elastic tape application helps improve the dynamic balance ability and arch of the foot. CONCLUSION: The non-elastic tape technique is helpful for the foot arch function, and there is no difference in the static balance ability between Kinesio tape and non-elastic tape. Nevertheless, non-elastic tape is more helpful for the dynamic balance ability than Kinesio taping.