• Title/Summary/Keyword: Extinguishing Container

Search Result 9, Processing Time 0.025 seconds

A Development of Methodology for NOVEC Gas Fire Extinguishing System (NOVEC 가스 소화 설비 설계방법론 개발)

  • Yun, Jeong-In;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.206-210
    • /
    • 2015
  • The most important thing for NOVEC gas fire extinguishing equipment is to release NOVEC gas, which contained in the extinguishing container, to the safety section by the time appointed. For this matter, it is significant to decide arrangement and size of the proper piping equipment. This study has developed the design methodology of NOVEC gas fire extinguishing equipment in use of pipe network analysis techniques. Based on the design methodology, each design coefficient is chosen. It is found that the calculated result, which is 6.498 seconds, has been counted within the 10 seconds limit, which is fairly satisfied with extinguishing releasing time based on the developed methodology. At that time, the pressure loss is 21.09bar.

Implementation of Automatic Extinguishing System for fire suppression of vehicle (차량 화재 진압을 위한 자동 소화 시스템 구현)

  • Ryu, Hye-Yeon;Kim, Man-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2019
  • In recent years, vehicle fires account for the second highest rate after residential fires. It accounts for more than 10.7% of the total fire occurrence rate. Vehicle fires are very difficult to evolve at an early stage. Most of the vehicles are burned down in the event of a fire, resulting in a lot of physical and personal damage. In the EU and other countries, efforts are being made to install automatic fire extinguishing systems in preparation for vehicle fires. In addition, since the automatic fire extinguishing system applied to a vehicle must operate in a moving state of a car, a method for detecting a fire is needed. Therefore, this paper proposes a structure of an automatic fire extinguishing system that can evolve a fire when a fire occurs in a commercial vehicle among various vehicles. Especially, it confirms the feasibility of the automatic fire extinguishing system simulated in the laboratory environment and confirms its applicability.

A Study on Discharge Characteristics from the Nozzle Orifice Attached to a Modularized Fire Extinguishing Gas-agent Container Under Horizontal Position (용기 일체형 가스소화 방식의 오리피스 방사 특성에 관한 연구)

  • 김윤증;윤명오;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.59-69
    • /
    • 2002
  • The conventional fire extinguishing gas-agent system has a configuration in which the gas-agent comes out of a cylindrical container having vertically settled shape. However, in this study a horizontally installed container of a piping shape having a cylinder of the same shape with a cylinder valve and a discharge nozzle was used, and the relationship between orifice size of nozzle and discharge rate of gas-agent was investigated through various experiments including the measurement of discharge rate under different ambient-temperature conditions. In such experiments, HCFC Blend A was used without super-pressurization by nitrogen. From this research, it was observed that statutory discharge duration of 10 seconds can be met if the relatively large size of the valve and the nozzle orifice were properly selected.

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

Structural Safety Evaluation for Fixed CO2 Extinguishing Systems Under Ship Motion (선박모션에 따른 고정식 CO2소화 장치 구조안전성 평가)

  • Kim, Seung Chan;Kang, Sang Hoon;Choi, Joo Hyoung;Kim, Jeong-Hwan;Park, Young Chul
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.75-83
    • /
    • 2016
  • Since fire is one of the most dangerous threats to the safety of the ship, from the safety device is installed on the vessel the digestive apparatus can be viewed as the most important safety device. The fire-extinguishing device to be mounted to the vessel structure affected the stability of the structure in accordance with the blue of the sea. In particular, the Rack part of the basic safety of a fixed fire extinguishing system in the absence of a $CO_2$ container. In this paper, by utilizing simulation techniques to apply the pressure data being ejected in each direction by ship motion and $CO_2$ containers Rack perform an analysis of the structural safety assessment was part of the digestive system accordingly.

Development of Independent Sprinkler for Fire Safety (소방안전을 위한 독립 스프링클러 개발)

  • Yun, Hae-Yong;Kim, Seon-Yeop;Kim, Ho-Chan;Park, In-Beck
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2017
  • Sprinklers are a necessary device for the early suppression of fires to prevent large fires. The installation has been obligatory for certain buildings recently through the digestion method. In an aging building, it is difficult to find sprinklers, because of their significant cost, long installation times, and they require installation by experts. That is why we are able to install all, was designed with enough independent integrated sprinklers with fire-extinguishing capabilities. The designed sprinklers are fitted with a conventional sprinkler head in a container of 20cm * 20cm * 10cm. Inside the container and potassium carbonate, which warms the rubber material and the plate line by pressing the potassium carbonate, the line weight is a 5kg pressing plate at the entrance at the pressure of 0.5Mpa when operating. The glass sprinkler valve blocking the entrance at about $68^{\circ}C$ is operated open. At this time, the potassium out of the digestive fire to combustible materials and heat off a chain reaction.

Characterization of Pre-service Elementary Teachers' Scientific Reasoning in Experimental Design: Interaction between Knowledge and Reasoning (실험 설계에 나타난 초등 예비교사의 과학적 추론의 특징: 지식과 추론의 상호작용)

  • Jang, Byung-Ghi
    • Journal of Korean Elementary Science Education
    • /
    • v.31 no.2
    • /
    • pp.227-242
    • /
    • 2012
  • This research explores the scientific reasoning of pre-service elementary teachers in experimental design. The article focuses on pre-service teachers' responses to the questions in the worksheets which involve making their knowledge claims on extinguishing of a burning candle in a closed container, evaluating anomalous data, and designing experiment to test their ideas. Their responses are interpreted in terms of categories developed by Tytler and Peterson(2003, 2004). The interrelationship between conceptual knowledge and scientific reasoning is explored using the data. It is argued that coordination of ideas and evidence must be emphasized in the scientific investigations rather than fair test.

A Numerical Study on the Design of Water Mist Lance for Fire Suppression in Container (컨테이너 내부 화재진압을 위한 물분무창 설계에 관한 수치적 연구)

  • Han, Sang-goo;Choi, Jae-hyuk;Lee, Won-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.941-947
    • /
    • 2017
  • Increasing marine transportation of dangerous goods using containers causes fire accidents on ships due to leakage of dangerous materials. In IMO (MSC.93), all vessels that are to be loaded five or more containers on weather deck area after 1 January 2016 are required to have a fire extinguishing system called Water Mist Lance (WML) on board. In this study, numerical analysis is performed to design WML with optimal edge radius of curvature using LS-DYNA. The analysis results for the three models with 10 mm, 15 mm and 20 mm lengths of the edge part showed that the only model with 15 mm length penetrated the wall of the container and did not cause damage to the edge of the WML. In the future, based on the results of this study, we will make a WML of prototype and conduct a performance test. And we will continue to improve the problems.