• 제목/요약/키워드: External Wall

검색결과 558건 처리시간 0.027초

External rf plasma treatment effect on multi-wall carbon nanotubes grown inside anodic alumina nanoholes at low deposition temperatures

  • Ahn, Kyoung-Soo;Kim, Jun-Sik;Kim, Eun-Kyu;Kim, Chae-Ok;Hong, Jin-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.692-693
    • /
    • 2002
  • Well-aligned multi-wall carbon nanotubes (MWNTs) were fabricated by utilizing a radio frequency plasma-enhanced chemical vapor deposition (rf-PECVD) system from Ni particles at the bottom of anodic alumina nanoholes (AAN). To remove the amorphous graphite layers on the AAN surface and to eliminate the protrusion of MWNT tips, the AAN surface with MWNTs were treated by external rf plasma source. As a result, the AAN surface almost became flat without having any protrusion of MWNT tips. The diameter, length of MWNTs and AAN were investigated by using a scanning electron microscopy (SEM). Raman spectroscopy was also used to characterize wall structure of the carbon nanotube. And the emission properties of the MWNTs were measured for the application of field emission display (FED) in near future.

  • PDF

외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량 (Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation)

  • 이규남;정근주
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.91-98
    • /
    • 2017
  • In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

벽돌조 건축문화재 외벽체의 훼손 현황 및 원인 조사 -나주노안천주교회를 중심으로- (Investigation of Defects and Damage on External Wall in Brick Structures of Modern Architectural Properties - Focused on "Naju Noahn Catholic Church" -)

  • 우남식;김태영
    • 한국농촌건축학회논문집
    • /
    • 제15권1호
    • /
    • pp.29-36
    • /
    • 2013
  • This study is to diagnose causes of damage and defects on external walls of brick structures, focused on "Naju Noahn" Catholic Church of Modern Architectural Properties. The causes of crack and deflection are overloading, shortage strength of arch. Among those, main cause is cauesd by shortage strength of arch because center of arch is dislocated and skew back of arch is small angle. The causes of damage and elimination are weathering, plants of friction, freezing and thawing, durability decrement of material and attach defection. This defects and damage is caused by high-moisture that occurs in soil. The causes of discoloration are change of soil moisture and flimsy brickwork. These defects and damage are mainly occurred in coping of cornice, weathering of window sill.

조선시대 전통건축에서의 화방벽(火防壁) 사용에 대한 연구 (A Study on the Usage of Hwabangbyeok wall in Traditional Architecture in Joeson Dynasty)

  • 조상순
    • 건축역사연구
    • /
    • 제29권3호
    • /
    • pp.7-14
    • /
    • 2020
  • It can be meaningful that this study attempted to analyze the use cases and forms based on the literature on the painting walls of the J oseon Dynasty, and attempted basic research to prevent disaster damage using traditional elements. This study summarizes the use of the Hwabangbyeok wall of J oseon Dynasty as follows. First, Hwabangbyeok wall was used from the early J oseon Dynasty and was adopted by palaces and other major state facilities to cope with fire and theft. Second, the Hwabangbyeok Wall was also referred to as the wall below the lower part of the wall, and was constructed with the purpose of preventing disasters from outside. Third, in an analysis of the Daeseongjeon shrine of Hyanggyo, many construction cases were identified mainly in the Gyeonggi area, which is assumed to be based on production and construction conditions along with local climatic factors. Fourth, it can be said that the Hwabangbyeok wall was basically adopted to prevent comprehensive disaster risk reduction in case of external intrusion and fire.

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

정적기립자세와 치료적 클라이밍 기립자세 시 체간근 근활성도의 비교 (Comparison of Trunk Muscle Activity during Static Standing Position and Standing Position on Therapeutic Climbing Wall)

  • 김세훈;이정인
    • The Journal of Korean Physical Therapy
    • /
    • 제26권1호
    • /
    • pp.27-32
    • /
    • 2014
  • Purpose: The purpose of the study was to comparison of trunk muscle activity during static standing position and standing position on therapeutic climbing wall of adult. Methods: Study subject is arbitrarily classified into 10 of experimental group and 10 control group among 20 of adult. Trunk activity measured as rectus abdominalis, external oblique, internal oblique, erector spinae. Control group maintains that center of gravity of trunk pass the front of shoulder, pelvis, knee and ankle on stable surface with putting legs apart more than shoulder width. Experimental group had static exercise on 4 by 3 meter, 90 degree of Therapeutic climbing wall. Starting position is that putting arms and legs apart more than shoulder width. In order to compare the effect of it between the groups, independent t-test was used. Results: According to the test result, significant difference between among rectus abdominalis, erector spinae the experimental groups. And external oblique, internal oblique muscle atvity is no significant difference experimental groups between among the control groups was observed. Conclusion: Trunk muscle activation is activated to standing position on the Therapeutic Climbing Wall more than static standing position.

단열 복층유리 PV의 커튼 월 적용 가능성에 관한 실험적 연구 (The Experimental Study on the Application of the Insulated Glass PV Module in the Curtain Wall)

  • 오민석;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.63-69
    • /
    • 2006
  • In order to positively cope with the international environmental regulations like UNFCCC (UN Framework Convention on Climate Change) and to overcome energy crisis Korea, who depends on import for more than 97% of required energy, needs to continuously proceed to development, spread and expansion of alternativeenergy and then, to cultivate the capacity to keep the balance of demand and supply of energy by itself. In this aspect, the technology of BIPV (Building Integrated Photovoltaic) is the field that the world is most interested in. However, at present, this technology is centered on increasing the efficiency of the module itself so it has lots of problems to be applied to buildings. Application of the integrated PV system in building external curtain wall can obtain much more generation of electric power than in roof-types whose area for installation is restricted, so it is excellent in terms of its possibility of application. Therefore, this paper intends to advance its practical use by proposing how to get integrated PV system which can be applied to building external curtain wall, and how to apply it.

BIPV에서 Flexible PV의 각도 조절을 이용한 MPPT 추적 알고리즘 연구 (A study on the MPPT tracking algorithm using angle control of flexible PV in BIPV)

  • 김재진
    • 디지털산업정보학회논문지
    • /
    • 제13권3호
    • /
    • pp.27-33
    • /
    • 2017
  • In this paper presents the MPPT tracking algorithm using angle control of flexible PV in BIPV. The proposed algorithm is based on MPPT tracking algorithm for curtain wall using flexible PV. It is an algorithm to find optimal power generation condition by controlling the angle of flexible PV using the air layer of window. The angle of flexible PV tests the power generation by separating the center of flexible PV into the interior angle in the interior direction and the external angle in the center of flexible PV. When the angle of flexible PV was used as interior angle, the generation amount was increased by 15.79% and increased by 8.45% compared with the external angle. MPPT tracking is performed on the generation amount of the interior angle which has the most power after comparing the generation amount according to the bending shape of the flexible PV. This algorithm can be the most efficient method for the curtain wall using flexible PV because the bending pattern with the greatest amount of power generation may be different because the environment of the building applying the curtain wall is different.

압밀주입에 의한 지반개량 특성고찰 (The Evaluation on Behavior of Segmental Grid Retaining Wall by Model Test)

  • 김상수;배우석;이종규
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.162-171
    • /
    • 2006
  • Segmental Grid Retaining Wall is one of the segmental grid retaining walls using headers and stretchers to establish the framework of the wall In this method, grids formed by the intersection of headers and stretchers are generally filled with the gravel to maintain the weight of the wall Therefore, the construction can be carried out with higher speed and much economically when compared with the concrete retaining wall Furthermore, it has high drain capacity, and environmentally friendly aspects also have been pointed out because the possibility of the planting at the front of the wall However, in the segmental grid retaining wall method, the relative movement between the individual headers and stretchers was generally recognized, and stress redistribution in the gravel filling was also observed when subjected to the external loading and self-weight of filling Therefore, it has been thought that the distribution of the earth pressure in the segmental grid retaining wall system differ from that of the concrete retaining wall In this study, the surcharge tests using the scaled model segmental grid retaining wall was carried out to observe the distribution of the earth pressure in the segmental grid retaining wall The earth pressure was measured in the six specified height of wall, and the distribution of the pressure was analyzed. Furthermore, the earth pressure by computation or by the test using the concrete retaining wall was also considered to make comparison

  • PDF

CLSM을 이용한 고해과정 중 섬유벽 두께 변화의 종이 특성 영향 분석 (Effects of Fiber Wall Thickness on Paper Properties Using CLSM)

  • 김서환;박종문;김철환
    • 펄프종이기술
    • /
    • 제31권1호
    • /
    • pp.39-45
    • /
    • 1999
  • Refining in papermaking plays an important role in changing fiber properties as well as paper properties. The major effects of refining on pulp fibers are internal and external fibrillation, fiber shortening, and fines formation. Many workers showed that internal fibrillation of the primary refining effects was most influential in improving paper properties. In particular, refining produces separation of fiber walls into several lamellae, thus causing fiber wall swelling with water penetration. This leads to the increase of fiber flexibility and of fiber-to-fiber contact during drying. If the fibers are very flexible, they will be drawn into close contact with each other by the force of surface tension as the water is removed during the drainage process and drying stages. In order to study the effect of fiber wall delamination on paper properties, cross-sectional image of fibers in a natural condition had to be generated without distortion. Finally, it was well recognized that confocal laser scanning microscope (CLSM) could be one of the most efficient tool for creating and quantifying fiber wall delamination in combination with image analysis technique. In this study, the CLSM could be used not only to observe morphological features of transverse views of swollen fibers refined under low and high intensity, but also to investigate the sequence of fiber wall delamination and fiber wall breakage. From the CLSM images, increasing the specific energy or refining decreased the degree of fiber collapse, fiber cross-sectional area, fiber wall thickness and lumen area. High intensity refining produced more external fibrillation.

  • PDF