• Title/Summary/Keyword: Exposure equipment

Search Result 433, Processing Time 0.029 seconds

Laboratory Biosafety Status of Researchers in Korea (국내 연구원들의 생물안전 개념에 대한 현황)

  • Kim, Dae Sik;Kim, Mi Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.1
    • /
    • pp.71-76
    • /
    • 2018
  • This study examined the status of the laboratory biosafety of researchers in Korea during 03 Jan 2017~25 Mar 2017. Questionnaires were given out to 500 researchers working with pathogens in the laboratory of universities and institutes. According to the results, the respondents showed a high level of awareness but not compliance on the overall biosafety rules and regulations. Regarding the Biosafety facility level, 279 (55.8%) of respondents answered "know" and 221 (44.2%) of respondents answered "no". Despite the insufficient safety equipment and biosafety plans, researchers believed that appropriate safety measures could protect the workers and that their laboratories are safe. In a study involving biosafety education, 80% of the researchers had been trained in laboratory safety and 20% had never received safety education. The need for biosafety education was 66% and the satisfaction rate of education was 46%. These results suggest that the researchers already had experience in biosafety training, but they believed that continuing education is necessary. In addition, there were opinions that the most important thing to improve the biosafety status is to strengthen the training program and education system. In conclusion, it is necessary to develop a better training system for laboratory biosafety regarding the exposure risks.

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.

Triathlon-Related Overuse Injury and Medical Issues (트라이애슬론의 과사용 부상과 의학적 위험요인에 대한 고찰)

  • Park, Chan-Ho;Kwak, Yi-Sub;Kim, Tae-Un
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.314-320
    • /
    • 2010
  • As the nature of triathlons is competition in three successive sports, triathletes experience elevated levels of stress on the body that are absent in single-sport athletic events, and consequently there are more potential medical problems to prepare for. Triathletes can also experience problems such as hypothermia, heat illness, excessive exposure to ultraviolet radiation, musculoskeletal injuries and trauma, immunosuppression, and haemolysis. Depending on the potentiality of such above-listed problems occurring in any given race, race organizers will prepare preventative measures and treatments accordingly. Olympic distance is not the only triathlon racing distance. Sprints, which are normally around half the Olympic distance, are common distances, as well as Long (2 km swim, 80 km bike, 20 km run), Ironman (3.8 km swim, 180 km bike, 42 km run), and ultra-distance events varying in length. Races of longer duration normally result in a higher percentage of athletes experiencing the above-mentioned medical problems, as well as inducing additional health risks such as hyponatraemia. Minimizing the occurrences of serious health issues is possible through the following means: carefully preparing for the probable race-day weather conditions; proper management and organization of the race; preparing an extensive water-safety and ground-course safety plan; distributing necessary nutrition along the course; and stressing the importance for athletes to have proper knowledge concerning race nutrition, biomechanical technique, physical preparation, and utilization of safe equipment. While risks of competing in triathlon are many, the instances of such medical problems are not excessive, and the triathlon has a reputation of being a reasonably safe sport as long as athletes with high risk take added precautions.

Pattern Recognition Analysis for Volatile Compounds of the Whole, Skim, UHT-, HTST-, and LTLT-Milk under LED Irradiations (여러 가지 LED를 처리한 전지유, 무지방 우유, LTLT, UHT, HTST 처리 우유의 휘발성분 패턴 분석)

  • Kim, Ki-Hwa;Hong, Eun-Jeung;Park, Sue-Jee;Kang, Jee-Won;Noh, Bong-Soo
    • Food Science of Animal Resources
    • /
    • v.31 no.4
    • /
    • pp.596-602
    • /
    • 2011
  • The objective of this study was to analyze the pattern recognition of volatile compounds from different types of milk under LED (Light Emitting Dioxide) irradiation for 6 d. Yellow, red, blue, dark, and fluorescent light were produced using LED equipment. A mass spectrometry-based electronic nose and DFA (discriminant function analysis) were used to determine the change in volatiles from different types of milk under LED irradiation. As the LED exposure time was increased, DF1 of whole milk changed considerably under blue light, while that of skim milk changed significantly under red and yellow light irradiation. Among the types of milk tested, the most light-induced oxidation sample was LTLT milk under blue light. The volatile compounds that were shown to increase due to LED treatment in the electronic nose analysis, which was based on MS, were mainly acetaldehyde, propanal, pentanal, hexanal, heptanal, nonanal, 3-methyl butanal, 2-methyl propanal, 2-butanone, 2-pentanone, 2-hexanone, and 2-heptanaone and 2-nonanone.

Exposure Assessment of Hazardous gases in Confined Spaces (밀폐공간 종류별 유해가스 발생 농도 평가)

  • Park, Hyunhee;Yoo, Kye-mook;Ham, Seung-hon;Chung, Kwang-Jae;Shin, Min-a;Lee, Koo-yong;Jang, Kyung-jo;Yoon, Chung-sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.381-389
    • /
    • 2009
  • Confined spaces are inherently dangerous workplace and many fatal and nonfatal accidents have been reported. Even though these accidents occur in various kinds of confined spaces, there has rarely been reported on the health hazard agent, i.e., the types of gases and their concentration ranges. Therefore in this study, we evaluated several toxic and asphyxiating gas concentrations in various confined spaces. We surveyed 57 manholes, 3 sewage treatment plants, 2 yellow radish manufacturing companies and 7 barges to measure the concentrations of oxygen($O_2$), hydrogen sulfide($H_2S$), carbon monoxide(CO), ammonia($NH_3$). Lower Explosion Limits(LEL) and Volatile Organic Compounds (VOCs). Those four types of confined spaces occupies 56% of accidents during last 9 years in Korea. In 57 manholes, the concentration varied according to the types of manholes; rainfall and sewage, and by location; residential and industrial areas. Sewage manhole in industrial area was evaluated as the most hazardous than other types of manhole like rainfall manholes, residential sewage manholes. The highest $H_2S$ concentration and the lowest $O_2$ concentration at sewage manhole in industrial area were 300 ppm, 8.7% respectively. In 3 sewage treatment plants, $H_2S$ and $NH_3$ concentrations were reached up to the 500 ppm and 200 ppm respectively. Two yellow radish manufacturing companies showed the concentrations of 316 ppm, 505.2 ppm, 90 ppm and 15.7% for $H_2S$, CO, VOCs and $O_2$, respectively. Seven barges showed 15.9%~20.9% oxygen concentration. Gas species and concentration ranges varied by the types and location of confined spaces; CO, $H_2S$, $O_2$ could be hazardous in manhole, especially manhole connected to sewage plants. CO, $H_2S$, LEL, $O_2$, $NH_3$ should be controlled in sludge silo and sluge pumping confined spaces in sewage treatment plant. The activity of lifting out radish from the storage tank was evaluated more hazardous rather than the other activities in yellow radish manufacturing industry. The employers must conduct the survey to identify all possible confined spaces in their local workplace prior to performing the tasks. At the national level to reduce the accidents in the confined spaces, we suggest that systemic approach and active education program including possible hazards, standard operation procedures, ventilation plan, and personal protective equipment in confined spaces should be implemented.

Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb (오픈소스 기반 수술항법장치의 하지 골절수술 응용검토)

  • Joung, Sanghyun;Park, Jaeyeong;Park, Chul-Woo;Oh, Chang-Wug;Park, Il Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.497-503
    • /
    • 2014
  • Minimally invasive intramedullary nail insertion or plate osteosynthesis has shown good results for the treatment of long bone fractures. However, directly seeing the fracture site is impossible; surgeons can only confirm bone fragments through a fluoroscopic imaging system. The narrow field of view of the equipment causes malalignment of the fracture reduction, and radiation exposure to medical staff is inevitable. This paper suggests two methods to solve these problems: surgical navigation using 3D models reconstructed from computed tomography (CT) images to show the real positions of bone fragments and estimating the rotational angle of proximal bone fragments from 2D fluoroscopic images. The suggested methods were implemented using open-source code or software and evaluated using a model bone. The registration error was about 2 mm with surgical navigation, and the rotation estimation software could discern differences of $2.5^{\circ}$ within a range of $15^{\circ}$ through a comparison with the image of a normal bone.

Study on Image Quality and Radiation Dose due to the Arm Position in the Abdomen/Pelvis CT (복부/골반 CT 검사 시 팔의 위치에 따른 방사선 선량과 영상화질 비교 연구)

  • Lee, Jongwoong;Won, Doyeon;Jung, Jaeeun;Kim, Hyeongyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.337-342
    • /
    • 2015
  • The one-year-follow-up test of abdomen/pelvis from 10 patients who were scanned more than twice a years were analyzed the radiation dose and image quality depend on the position of the arm retrospectively from January to December in 2013. There were classified two groups, group A was examined with raising an arm on standard position and group B was performed with lowering an arm, respectively. Group A of an average mAs from the first dose amount was shown 11.4% less compared to Group B. And the value of CTDI from Group B also was investigated 11.3% less. To compare the quality comparison of the second image as histogram value, the value of max from both of two groups was measured similarly. However, a big difference was shown from the value of min and SD, the short dose was appeared depends on the position of arm even though Group A was radiated more than Group B. Less exposure to the medical image quality only by working CT scan when the examiner actively raise the arm before the development and testing of high-end equipment introduction of complex algorithms for obtaining an optimized image will be provided to the patient.

The Evaluation of CR and DDR chest image using ROC analysis (ROC평가 방법을 이용한 CR과 DDR 흉부 영상의 비교)

  • Park, Yeon-Ok;Jung, Eun-Kyung;Park, Yeon-Jung;Nam, So-Ra;Jung, Ji-Young;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • ROC(Receiver Operating Characteristic)curve is the method that estimate detected insignificant signal from the human's sense of sight, it has been raised excellent results. In this study, we evaluate image quality and equipment character by obtaining a chest image from CR(Computed Radiography) and DDR(Direct Digital radiography) using the human chest phantom, The parameter of exposure for obtaining chest image was 120 kVp/3.2 mAs and the SID(Source to Image Distance) was 180cm. The images were obtained by CR(AGFA MD 4.0 General plate, JAPAN) and DDR(HOLOGIC nDirect Ray, USA). Using some pieces of Aluminum and stone for expressing regions, then attached them on the heart, lung and thoracic vertebrae of the phantom. 29 persons hold radiology degrees were participated in ROC analysis. As a result of the ROC analysis, TPF(true positive fraction) and FPF(false positive fraction) of DDR and CR are 0.552 and 0.474 and 0.629 and 0.405, respectively. By using the results, the ROC curve of CR has higher image quality than DDR. According to the theory, DDR has the higher image quality than CR in chest X-ray image. But, CR has the higher image quality than DDR. quality of DDR inserted the enhance board. The results confirmed that image post-processing is important element decipherment of clinical.

  • PDF

Correlation Analysis of Meteorological Factors for Wooden Building in Beopjusa and Seonamsa Temples by Statistical Model (통계적 모형을 통한 법주사와 선암사 목조건축물의 기상인자에 대한 상관성 분석)

  • Kim, Young Hee;Kim, Myoung Nam;Lim, Bo A;Lee, Jeung Min;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.387-396
    • /
    • 2018
  • Exposure to the natural environment can cause damage to domestic wooden cultural assets, such as temples. Deterioration is accelerated by biological damage and various environmental factors. In this study, meteorological factors were monitored by equipment installed at Beopjusa temple of Boeun province and Seonamsa temple of Suncheon province. A statistical model was applied to these data to predict the meteorological factors and to compare the predictive performance of each meteorological factor. The resulting correlation coefficient between air and dew point temperatures was highest, at 0.95, while the correlation coefficient for relative humidity had a moderate value(0.65) at both the Beopjusa and Seonamsa temples. Thus, a general linear model was found to be suitable for predicting air and dew point temperatures. An analysis of correlation between meteorological factors showed that there was strong positive correlation between air temperature and dew point temperature, and between solar radiation and evaporation at both sites. There was a weak positive correlation between air temperature and evaporation at Beopjusa temple. Wind speed was negatively correlated with both air temperature and relative humidity at Seonamsa temple. The wind speed at this location is higher than average in winter and lower than average in summer, and it was hypothesized that the low wind speed plays a role in reducing water evaporation in summer, when both air temperature and relative humidity are high. As a result, damage to the wooden buildings of Seonamsa temple is accelerated.

Corrosion Behavior of $Y_2O_3$ Coating in an Electrolytic Reduction Process (전해환원공정에서 $Y_2O_2$ 코팅층의 부식거동)

  • Cho, Soo-Haeng;Hong, Sun-Seok;Kang, Dae-Seung;Jeong, Myeong-Soo;Park, Byung-Heong;Hur, Jin-Mok;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • The electrolytic reduction of a spent oxide fuel involves a liberation of the oxygen in a molten LiCl electrolyte, which results in a chemically aggressive environment that is too corrosive for typical structural materials. Accordingly, it is essential to choose the optimum material for the processing equipment that handles the high molten salt. In this study, hot corrosion studies were performed on bare as well as coated superalloy specimens after exposure to lithium molten salt at $675^{\circ}C$ for 216 h under an oxidizing atmosphere. The IN713LC superalloy specimens were sprayed with an aluminized NiCrAlY bond coat and then with an $Y_2O_3$ top coat. The bare superalloy reveals an obvious weight loss due to spalling of the scale by the rapid scale growth and thermal stress. The chemical and thermal stability of the top coat has been found to be beneficial for increasing to the corrosion resistance of the structural materials for handling high temperature lithium molten salts.