• Title/Summary/Keyword: Exposure System

Search Result 2,305, Processing Time 0.031 seconds

VME bus based control system for step & scan exposure tool (VME bus를 이용한 Step & Scan형 노광장비의 Control System 구성)

  • 최용만;오병주;김도훈;정해빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.672-675
    • /
    • 1997
  • This paper proposes a structure of the control system for the step & scan exposure tool. The step & scan exposure tool is used for the manufacturing process of the semiconductor DRAM memory of giga bit. The control system employs the VME bus instead of the conventional ISA bus so that all control signals and data can be managed separately by the 4 VME-PCs for fast and fault-free flow of signals for multi-tasking. A high speed I/O card is equipped for the real-time monitoring and control of the sub module equipment. Then all the subsystems are integrated and aligned for the operation of the step & scan exposure tool with the VME bus and, I/O card.

  • PDF

An expert system for making durable concrete for chemical exposure

  • Islam, Md. Nazrul;Zain, Muhammad Fauzi Mohd.;Basri, Hassan
    • Computers and Concrete
    • /
    • v.2 no.4
    • /
    • pp.293-307
    • /
    • 2005
  • The development and the main features of an expert system for modeling the requirements of durable concrete in chemical exposure, called the Durable Concrete Advisor for Chemical Exposure (DCACE), are described. The system was developed to help improve the quality of concrete exposed to chemical environment by minimizing mistakes and deficiencies in selecting concrete constituents. Using Kappa-PC expert system shell, an object-oriented model was developed where the rule-based reasoning operates on or across objects. The American Concrete Institute manual of concrete practice was chosen as the main source of knowledge. Other textual sources were also consulted for knowledge acquisition. The major objectives of the research were acquisition and formalization of the relevant knowledge and building an expert system for making durable concrete for chemical exposure regarding sulfate attack, acid attack, seawater attack and carbonation. Similar to most expert systems, this system has explanation facilities, can be incrementally expanded, and has an easy to understand knowledge base. The performance of the system is demonstrated by an example session. The system is user-friendly and can be used as an educational tool.

Ozone Exposure Assessment by Population Characteristics: A Case Study for High Ozone Days in Busan (인구특성을 고려한 노출평가: 부산지역 고농도 오존일 사례연구)

  • Hwang, Mi-Kyoung;Bang, Jin-Hee;Oh, Inbo;Kim, Yoo-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.71-81
    • /
    • 2015
  • Objectives: Photochemical ozone pollution is associated with increased mortality risk. This study aims to assess the population exposure to ozone according to population characteristics for high ozone days in the Busan metropolitan region (BMR). Methods: The ozone exposure assessment in this study was performed using the WRF-CMAQ simulated ozone concentrations and the population data in the BMR. The settled and daytime population and their activity were considered to conduct the static and dynamic ozone exposure assessment. Results: Applying a static exposure assessment, in case that high ozone occurred throughout Busan area, the highest exposure levels were evaluated in urban neighborhoods. In case of ozone pollution in outer Busan, because sensitive groups have been relatively higher exposure, this case was also evaluated as part of that should not be overlooked. The dynamic exposure was higher than static exposure because the number of population exposed to ozone of high concentration is increased. This approach is important in a regard consider that daytime population distribution when high ozone occur. Conclusion: This study shows the different population exposure according to various ozone distributions for each episode day. Considering demographic characteristic such as population density and activity should be important to understanding the population exposure assessment when ozone pollution occurs.

The assessment of the automatic exposure control system for mammography x-ray machine

  • Kim, Hak-Sung;Kim, Sung-Chul
    • International Journal of Contents
    • /
    • v.9 no.2
    • /
    • pp.66-69
    • /
    • 2013
  • In the U.S., performance assessment on the Automatic Exposure Control system (AEC) is managed according to the Mammography Quality Standards Act (MQSA). However, The AEC is not available in the performance assessment conducted in Korea. Also, there is no study made on the performance of the automatic exposure control system for mammography in Korea. For this reason, this study examined the performance of the automatic exposure control system for mammography that was clinically used in the Incheon area. Result showed that the difference of the mean optical density was 0.79 ~ 2.81. This implies that some devices caused unnecessary x-ray exposure to patients. Furthermore, only 61.5% of the entire experimental device was shown to be satisfactory in terms of change in mean optical density. Moreover, in terms of the subject's thickness, change in radiographic density was shown to be severe among lower X-ray tube voltage while there was severe density change in X-ray image depending on X-ray tube voltage among the subjects with more thickness. Therefore, it is suggested to provide performance management on the AEC for mammography.

The effects of various exposure times in the detectability on the tips of the endodontic files in Digora$\textregistered$ (Digora$\textregistered$에서 노출시간의 변화가 근관치료용 file의 첨부식별에 미치는 영향)

  • Ko Jee-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.55-71
    • /
    • 1997
  • Digora/sup (R)/ an intraoral digital radiography system utilizing image plate (IP) - has a dynamic range of exposure time which allows it to decrease the patient's exposure time and to increase diagnostic ability through image processing, transmission and storage. The purpose of this study was to evaluate the Digora/sup (R)/ system by assessing the effects of various exposure times on the detectability on the tip of the endodontic file. Examining the root canals of 45 extracted sound premolars, K -files No. 10, 15, and 20 were placed at slightly varying distances from the apex. The teeth were glued onto resin-plaster blocks. Five exposure times varying between 0.01 seconds and 0.25 seconds were used. Four observers were asked to measure the distance between the tip of the file and a reduction of crown portion, and obtained mean errors (subtracting true file length from the measured file length), comparing Digora/sup (R)/ monitors with E-plus films, which were both obtained under the same geometrical positions. The results were as follows : 1. Comparing E-plus film with Digora/sup (R)/ at 0.01 seconds, the mean errors in E-plus film showed -4.453 nun, -4.497 nun, and -3.857 nun, while the mean errors in Digora/sup (R)/ showed 0.065 nun, 0.607 nun, and 0.719 mm according to the file groups. Therefore there was a significant difference between E-plus film and Digora/sup (R)/(p<0.05). 2. By comparison of mean errors according to the various exposure times in the Digora/sup (R)/ system, the mean error at 0.01 seconds was significantly lower than that at 0.12 and 0.25 seconds in the No. 10 file group(p<0.05). And the standard deviation was the highest at 0.01 seconds. 3. Comparing E-plus film at 0.25 seconds with the Digora/sup (R)/ system, the mean errors showed a significant difference between E-plus film at 0.25 seconds and the Digora/sup (R)/ system at 0.25 seconds in No. 10 and 20 file groups(p<0.05). 4. Comparing E -plus film at 0.25 seconds with other exposure times, the mean errors showed a significant difference between E-plus film at 0.25 seconds and E-plus film at 0 .. 01 and 0.03 seconds in 10 file group(p<0.05). In the No. 15 and 20 file groups, there was a significant difference between E-plus film at 0.25 seconds and E-plus film at 0.01 seconds(p<0.05). In conclusion, Digora/sup (R)/ was better than E-plus film in detectability on the tip of the file at the exposure time of 0.01 seconds in all file groups. And we concluded that Digora/sup (R)/ can shorten exposure times up to 4% of 0.25 seconds (0.01 sec), which is adequate exposure time for premolar in E-plus film using No. 15 and 20 files.

  • PDF

Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System

  • Plato, N.;Bigert, C.;Larsson, B.M.;Alderling, M.;Svartengren, M.;Gustavsson, P.
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.377-383
    • /
    • 2019
  • Objectives: Exposure to fine particles in urban air has been associated with a number of negative health effects. High levels of fine particles have been detected at underground stations in big cities. We investigated the exposure conditions in four occupational groups in the Stockholm underground train system to identify high-exposed groups and study variations in exposure. Methods: $PM_1$ and $PM_{2.5}$ were measured during three full work shifts on 44 underground workers. Fluctuations in exposure were monitored by a real-time particle monitoring instrument, pDR, DataRAM. Qualitative analysis of particle content was performed using inductively coupled plasma mass spectrometry. Nitrogen dioxide was measured using passive monitors. Results: For all underground workers, the geometric mean (GM) of $PM_1$ was $18{\mu}g/m^3$ and of $PM_{2.5}$ was $37{\mu}g/m^3$. The particle exposure was highest for cleaners/platform workers, and the GM of $PM_1$ was $31.6{\mu}g/m^3$ [geometric standard deviation (GSD), 1.6] and of $PM_{2.5}$ was $76.5{\mu}g/m^3$ (GSD, 1.3); the particle exposure was lowest for ticket sellers, and the GM of $PM_1$ was $4.9{\mu}g/m^3$ (GSD, 2.1) and of $PM_{2.5}$ was $9.3{\mu}g/m^3$ (GSD, 1.5). The $PM_1$ and $PM_{2.5}$ levels were five times higher in the underground system than at the street level, and the particles in the underground had high iron content. The train driver's nitrogen dioxide exposure level was $64.1{\mu}g/m^3$ (GSD, 1.5). Conclusions: Cleaners and other platform workers were statistically significantly more exposed to particles than train drivers or ticket sellers. Particle concentrations ($PM_{2.5}$) in the Stockholm underground system were within the same range as in the New York underground system but were much lower than in several older underground systems around the world.

Development and Application of a Chemical Ranking and Scoring System for the Management of Endocrine Disrupting Chemicals (환경성 내분비계장애물질(EDCs)의 우선관리순위 결정법 개발 및 적용)

  • Lim, Miyoung;Park, Ji Young;Ji, Kyunghee;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.76-89
    • /
    • 2018
  • Background: Exposure to endocrine disrupting chemicals (EDCs) has been considered one of the main causes of a range of endocrine diseases in modern society. An EDC priority list considering exposure, toxicity, and societal concern should be established for EDC management. Methods: The chemical ranking and scoring (CRS) system for EDCs was based on exposure, toxicity,and societal concern. The exposure score system was based on usage, circulation volume, bioaccumulation, and detection in consumer products. The toxicity score system was based on carcinogenicity and reproductive and developmental toxicity. The societal concern score system was based on domestic or international regulations and mass media reports. Results: A total of 165 EDCs were considered in the CRS system. The top-five priority EDCs were Bis(2-ethylhexyl) phthalate (DEHP), Benzene, Bisphenol A, Dibutyl phthalate (DBP) and Trichloroethylene. Phthalates, bisphenols and parabens were identified as priority chemical groups. Conclusion: We developed a CRS system for EDCs to identify priority EDCs for management. This will be a foundation to provide an EDC management plan based on scientific decision-making.

Design and Implementation of Auto-Focusing, Auto-Exposure and Auto-White balance Video Camera System (자동 초점 자동 노출 및 자동 화이트 밸런스 비디오 카메라의 설계 및 구현)

  • 김병수;이준석;정유영;고성제
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.17-20
    • /
    • 2001
  • This paper has been studied a vedio camera system with AF (auto-focus), AE (auto exposure), AWB(auto-whitebalance). And then this paper has designed an advanced method to improve AF, AE and AWB video camera system

  • PDF

Implementation of the VHOE-based Multiview 3D Display System by using Optimized Exposure-Time Scheduling Scheme

  • Kim, Seung-Chul;Gu, Jung-Sik;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.883-886
    • /
    • 2002
  • A new exposure time scheduling scheme to implement the optimized photopolymer-based VHOE is proposed and using this method, the 8-view VHOE system is experimentally developed. The CGS dependence on the exposure energy is mathematically modeled using the fourth-order polynomial function and using this model optimized exposure-time schedule for recording the given multiple gratings in the photopolymer is calculated. In addition, basing on this suggested exposure-time schedule, 8-view VHOE is finally implemented and its performance is discussed.

  • PDF

Methylmercury Exposure and Health Effects

  • Hong, Young-Seoub;Kim, Yu-Mi;Lee, Kyung-Eun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.6
    • /
    • pp.353-363
    • /
    • 2012
  • Methylmercury is a hazardous substance that is of interest with regard to environmental health, as inorganic mercury circulating in the general environment is dissolved into freshwater and seawater, condensed through the food chain, ingested by humans, and consequently affects human health. Recently, there has been much interest and discussion regarding the toxicity of methylmercury, the correlation with fish and shellfish intake, and methods of long-term management of the human health effects of methylmercury. What effects chronic exposure to a low concentration of methylmercury has on human health remains controversial. Although the possibility of methylmercury poisoning the heart and blood vessel system, the reproductive system, and the immune system is continuously raised and discussed, and the carcinogenicity of methylmercury is also under discussion, a clear conclusion regarding the human health effects according to exposure level has not yet been drawn. The Joint FAO/WHO Expert Committee on Food Additives proposed to prepare additional fish and shellfish intake recommendations for consumers based on the quantified evaluation of the hazardousness of methylmercury contained in fish and shellfish, methylmercury management in the Korea has not yet caught up with this international trend. Currently, the methylmercury exposure level of Koreans is known to be very high. The starting point of methylmercury exposure management is inorganic mercury in the general environment, but food intake through methylation is the main exposure source. Along with efforts to reduce mercury in the general environment, food intake management should be undertaken to reduce the human exposure to methylmercury in Korea.