• Title/Summary/Keyword: Experimental verification

Search Result 1,663, Processing Time 0.032 seconds

The Application and Experimental Verification of 2MVA BESS for Power Smoothing of Wind Turbine (풍력발전 출력 안정화를 위한 2MVA급 BESS 적용 및 실증시험)

  • Kim, Yun-Hyun;In, Dong-Seok;Kim, Sang-Hyun;Kim, Tae-Hyeong;Kim, Kwang-Seob;Kwon, Byung-Ki;Lee, Duk-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.540-541
    • /
    • 2012
  • 본 논문에서는 신재생에너지원인 1.5MW 풍력발전기가 연계된 계통에 2MVA/500kWh BESS(Battery Energy Storage System)를 적용하여 실증시험을 수행한 결과를 기술하였다. 풍력발전기의 출력 전력을 측정하여 제어 알고리즘에 따라 충, 방전 지령값을 계산하는 상위제어기 EMS와 BESS를 연동하여 운전하였다. 이를 통해 BESS를 이용하여 풍력발전기의 출력이 심하게 변동하여도 계통으로 송전되는 전력을 안정적으로 제어할 수 있음을 검증하였다.

  • PDF

DC Leakage Current Properties Analysis of the LED Lamps of Road and Landscape Lighting (LED 가로등 및 경관조명의 직류 누전 특성 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.885-891
    • /
    • 2011
  • In this paper, we studied dc leakage current properties analysis of LED lamps of road and landscape lighting when leakage current appeared in dc power line. Generally, converter of LED lighting is divides to insulated type and non-insulated type according to components. When electric leakage happened in AC power line, earth leakage breaker(ELB) senses leakage current and interrupts electric circuit. In dc power source, We need experimental verification about dc electric leakage for electricity safety. In normal wiring conditions and in the water, in case of using insulated type of converter, dc leakage current did not occur. However, in case of using non-insulated type of converter, dc leakage current occurred and passed through into the ground. We found that there is a hazard of electric shock by dc leakage current. We expect that the results of these studies would be helpful for electrical safety of LED lamps for road and landscape lighting.

Loss analysis of Current-Fed Full-Bridge DC-DC Converter with Active Clamp (능동 클램프형 전류형 단상 풀브리지 DC-DC 컨버터 실험 및 손실 분석)

  • Cha, Han-Ju;Ahn, Chi-Hyung;Choi, Soon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1149-1150
    • /
    • 2007
  • In this paper, operation of isolated current-fed full-bridge converter with active clamp is investigated by simulation and experiments. Experimental waveforms show a good agreement with the corresponding simulation results. Further, losses such as conduction loss, turn-on/off loss of MOSFETs and diodes are measured and their characteristics in the converter is addressed. 200W prototype DC-DC converter is developed for verification of the derived operating modes, design rules and loss analysis.

  • PDF

Analytical Approach and Experimental Verification for the Cogging Torque Reduction of Permanent Magnet Machines with Multi-pole Rotor (다극 회전자를 갖는 영구자석 기기의 코깅토크 저감을 위한 해석적 접근 및 실험적 검증)

  • Jang, Seok-Myeong;Choi, Jang-Young;Ko, Kyoung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1031-1032
    • /
    • 2007
  • In order to reduce the cogging torque, by predicting the variation of the cogging torque according to pole arc/pitch ratio by analytical and FE methods, pole arc/pitch ratio which makes the cogging torque minimum are determined. And then, the measurements of cogging torque for permanent magnet generators with determined pole arc/pitch ratio are presented. The reasons for the error between predicted and measured value are discussed fully in terms of the shape of permanent magnet. Finally, by confirming that predicted results for cogging torque according to pole arc/pitch ratio and skew are shown in good agreement with those obtained from measured one, the validation of analysis results is confirmed.

  • PDF

A Study on the Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 누설 인덕턴스에 대한 연구)

  • Lee, Hee-Kab;Park, Yong-Pil;Lee, Sung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.116-118
    • /
    • 2002
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances $L_{r1}\;and\;L_{r2}$ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

Investigation on failure assessment method for nuclear graphite components

  • Gao, Yantao;Tsang, Derek K.L.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.206-210
    • /
    • 2020
  • Super fine-grained graphite is a type of advanced nuclear graphite which was developed for Molten Salt Reactor (MSR). It is necessary to establish a failure assessment method used for nuclear graphite components in MSR. A modified assessment approach based on ASME BPVC-III-5_2017 is presented. The new approach takes a new parameter, KIC, into account and abandons the parameter, grain size, which is unrealistic for super fine-grained graphite as the computation is enormous if we use conventional methods. Three methodologies (KTA 3232, ASME, New approach) were also evaluated by theoretical prediction and experimental verification. The results indicated the new developed code can be used for design and failure assessment of super fine-graphite components and has more extensive applicability.

Experimental Verification of Set-Up Reference Values for the Determination of Downcoiling Tension in Hot Strip Mill (열간압연시 권취장력 설정기준치의 실험적 검증)

  • 공성락;강용기;김영환;문영훈
    • Transactions of Materials Processing
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • Set-up reference values, used in determining the optimum downcoiling tension, we experimentally verified in this study. During the actual downcoiling, the strip suffers both tension and bending force through the rotation of mandrel. Therefore, simulative test which can measure both tension and bending resistance of strip was performed to estimate set-up reference value for strip tension during downcoiling operations. The values obtained from the simulative test were correlated with the yield stress which has conventionally been used as reference values for downcoiling tension. The correlative analysis showed that the yield stress of strip can be a good reference value for downcoiling tension. Furthermore, the bending load also shows strong correlation with simulated values due to the close relationship between yield stress and bending load.

  • PDF

Practical Surface Sculpting Method for the Fabrication of Predefined Curved Structures using Focused Ion Beam

  • Kim, Heung-Bae
    • Applied Science and Convergence Technology
    • /
    • v.25 no.5
    • /
    • pp.92-97
    • /
    • 2016
  • Surface erosion using focused ion beam irradiation is the most promising technology for the realization of micro/nanofabrication. However, accurate fabrication of predefined structures is still challenging. This article introduces a single step surface driving method to fabricated predefined curved structures. The previously reported multi step surface driving method (MSDM) has been modified so that a single ion dose profile can be used instead of multiple ion dose profiles. Experimental realization of the method is presented with the fabrication of predefined curved surfaces as well as reference to surface propagation theory. For the purpose of verification, simulations are performed on the basis of a sound mathematical model.

Cabinet Design for Vibration Reduction of a Drum Type Washing Machine (드럼세탁기의 진동 감소를 위한 캐비닛 설계)

  • Yong, Seung Ji;Kim, Kwon Hee;Kim, Young Gwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.9
    • /
    • pp.731-737
    • /
    • 2016
  • In the quest for improved capacity and accelerated dehydration speed of drum type washing machines, an increase in vibration emerges as a major challenge. In an attempt to derive a new design with reduced vibration, a full finite element model of washing machine has been developed, with experimental verification. After modal analyses of several design variants, a new design of the cabinet has been proposed. Forced vibration analysis of the new model suggests that 19% reduction in cabinet vibration amplitude can be achieved with this design.

Development of Directional Digital Hearing Aid Performance Testing System (지향성 보청기 성능 검사 장치 개발)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.469-474
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-1ike the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The experimental results were compared with a boundary element method program for verification. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF