• Title/Summary/Keyword: Expanded Uncertainty

Search Result 197, Processing Time 0.096 seconds

A Study on Estimation uncertainty of measurement in mechanical characteristic exam for Plastic materials (플라스틱재료의 기계적 특성시험 불확도추정에 대한 고찰)

  • Kim Won-kyung;Kwon Sung-Tae;Kim Jung-Nam
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.301-306
    • /
    • 2003
  • Recently, uncertainty of measurement became a major concern for the people working on the laboratory evaluation and accreditation. 'uncertainty of measurement is a parameter associated with the result of a measurement that characteristics the dispersion of the value that could reasonably be attributed to the measured.' This study analysed how to estimate uncertainty of measurement in mechanical characteristic exam for Plastic material. its uncertainty was estimated according to International Organization for Standardization(ISO), they were named to A type uncertainty, B type uncertainty, combined standard uncertainty, and expanded uncertainty. We obtained that the combined standard uncertainty was 0.96697 MPa and the expanded uncertainty was 2.291MPa.

  • PDF

Uncertainty of Measurement in Nitrate Analysis from Burley Leaf Tobacco (버어리종 담배 중 질산성 질소에 대한 측정불확도)

  • Lee Jeong-Min;Lee Kyoung-Ku;Han Sang-Bin
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.2
    • /
    • pp.226-234
    • /
    • 2005
  • The uncertainty of measurement in nitrate from burley leaf tobacco by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of nitrate were weight of standard and sample, purity of standard, dilution of standard solution, calibration curve, water content, etc. The calculation of uncertainty based on the GUM(Guide to the Expression of Uncertainty in Measurement) and EURACHEM/CITAC Guide. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The concentration of nitrate from burley leaf tobacco was $2.09\%$ and the expanded uncertainty by multiplying by the coverage factor(k, 2.20) was $0.13\%\;at\;a\;95\%$ confidence level.

Calibration uncertainty of a spinning rotor gauge (스피닝 로터 게이지 교정 불확도)

  • 홍승수;임인태;신용현;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • Spinning Rotor Gauge (SRG) has been used to transfer standard gauge for international comparison at the high vacuum standards. We calibrated a spinning rotor gauge by using dynamic calibration system (DCS) that was a national high vacuum standards system. And its uncertainties were evaluated with the International Organization for Standardization (ISO), they were recognized ai A type uncertainty, B type uncertainty, combined Standard uncertainty, and expanded uncertainty. The combined standard uncertainties were $1.8007\times10^{-5}$ Pa ~ ~$4.8422\times10^{-5}$ Pa for this spinning rotor gauge.

Concept and Type for Degree of Freedom in Quality Statistics (품질통계에서 자유도 개념 및 유형)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.6
    • /
    • pp.193-196
    • /
    • 2007
  • This paper presents real examples of quality statistics for users to easily understand the concept and purpose for obtaining the degree of freedom. Moreover degree of freedom by Satterwaite can be used for linear combinations of unbiased variance. Finally effective degree of freedom by Welch-Satterthwaite is applicable to obtain expanded uncertainty considering type A and type B uncertainty.

Combustion Experiment Measurement Uncertainty for Hybrid Rocket Motor (하이브리드 로켓 모터에 대한 연소 실험 측정 불확도)

  • Kim, Soo-Jong;Moon, Hee-Jang;Kim, Jin-Kon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • In this study, the measurement uncertainty of combustion experimental system and experimental parameters for hybrid rocket were evaluated by B type evaluation method. The measurement uncertainty of all experimental parameters was lower than 3%. The highest value of expanded uncertainty was characteristic velocity efficiency with 2.83% and the expanded uncertainty of regression rate which is the design and performance parameter was indicated to 0.03%. These results shown that the reliability of hybrid combustion system was located within allowed limits.

Evaluation of Flow Measurement Uncertainty of Sonic Nozzle (소닉노즐의 유량측정 불확도 평가)

  • Choi, H.M.;Park, K.A.;Choi, Y.M.;Oh, Y.K.;Yoon, B.R.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.601-606
    • /
    • 2001
  • Measurement uncertainty should be evaluated according to ISO/IEC 17025. In Flow measurement area, uncertainty evaluation scheme was applied to the reference flow meter, sonic nozzle. Uncertainty was calculated by evaluating various uncertainty factors affected in flow measurement. The expanded uncertainty of the sonic nozzle was 0.21 % (confidence level of 95 %). This evaluation example will be useful in flow measurement uncertainty determination of other flow meters.

  • PDF

Development and Uncertainty Evaluation of New Piston (새로운 개념의 피스톤 푸루버 개발 및 불확도 평가)

  • Choi, Hae Man;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.354-359
    • /
    • 2002
  • The new piston prover was developed and the flow measurement uncertainty of this piston prover was evaluated according to ISO/IEC 17025. The laser interferometer was employed to measure accurately the testing time. Uncertainty was calculated with evaluation of various uncertainty factors affected in flow measurement. The expanded uncertainty(U) of the piston Over was $1.3{\times}10^{-3}$ (at the confidence level of $95\%$). This evaluation example will be useful in flow measurement uncertainty determination of other gas flow measurement system.

  • PDF

Development of Line Standards Measurement System Using an Optical Microscope (광학 현미경을 이용한 선표준물 측정 시스템 개발)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.72-78
    • /
    • 2009
  • We developed a line standards measurement system using an optical microscope and measured two kinds of line standards. It consists of three main parts: an optical microscope module including a CCD camera, a stage system with a linear encoder, and a measurement program for a microscopic image processing. The magnification of microscope part was calibrated using one-dimensional gratings and the angular motion of stage was measured to estimate the Abbe error. The threshold level in line width measurement was determined by comparing with certified values of a line width reference specimen, and its validity was proved through the measurement of another line width specimen. The expanded uncertainty (k=2) was about 100 nm in the measurements of $1{\mu}m{\sim}10{\mu}m$ line width. In the comparison results of line spacing measurement, two kinds of values were coincide within the expanded uncertainty, which were obtained by the one-dimensional measuring machine in KRISS and the line standards measurement system. The expanded uncertainty (k=2) in the line spacing measurement was estimated as $\sqrt{(0.098{\mu}m)^2+(1.8{\times}10^{-4}{\times}L)^2}$. Therefore, it will be applied effectively to the calibration of line standards, such as line width and line spacing, with the expanded uncertainty of several hundreds nanometer.

Uncertainty Analysis of Cross-Correlation Algorithm based on FFT by PIV Standard Images (표준 영상에 의한 FFT 기반 상호상관 PIV 알고리즘의 불확도 해석)

  • Lee, Suk-Jong;Choi, Jung-Geun;Sung, Jae-Young;Hwang, Tae-Gyu;Doh, Deog-Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • Uncertainty introduced by a cross-correlation algorithm based on FFT has been investigated using PIV standard images. The standard images were generated by the Monte Carlo simulation method. Both bias and random errors from the velocity vector have been analyzed with regard to the particle diameter, displacement, and the number of particles. The uncertainty of velocity is evaluated based upon the IS0/IEC standard. As a result, a total error of $0.26\%$ is included in the PIV cross-correlation algorithm. In addition, the uncertainty budget is presented, where the effect of the above three variables is examined. According to the budget, the variation of the number of particles within the interrogation window mainly contributes to the combined standard uncertainty of the real measured velocity field when excluding the effect of errors by the experiments itself. Finally, the expanded uncertainty is found to be about $12\%$ at the $95\%$ confidence level.

  • PDF