• 제목/요약/키워드: Exciter tests

검색결과 21건 처리시간 0.021초

사장교 케이블 동특성 평가를 위한 케이블 가진시스템 개발 (Development of Cable Exciting System for Evaluating Dynamic Characteristics of Stay Cables)

  • 김남식;정운;서주원;안상섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.424-429
    • /
    • 2003
  • As a critical member of cable-stayed bridges, stay cables play an important role of supporting the entire structure. Traffic, wind or rain-wind induced vibrations of stay cables would be a major cause of degrading both safety and serviceability of the bridge. One of the effective alternatives to solve this problem is to employ the cable dampers. In order to design the cable damper optimally. it is necessary to exactly estimate the dynamic characteristics of the existing cables. Therefore, in this study, a cable exciting system (exciter) controlled digitally was developed. And to evaluate the performance of the cable exciter developed, a solution of the differential equation of cable motion considering the exciter was derived. Using the cable exciter. sine sweeping and resonance tests on a cable model were carried out to obtain the dynamic characteristics effectively.

  • PDF

발전기 여자기시스템 주제어전원공급장치 국산화 개발 (The Development of EPSM(Exciter Power Supply Module) Localization in Generator Exciter(EX2100) System)

  • 이기선;박정철;추순남
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.101-107
    • /
    • 2016
  • The main target in this paper is the localization of VME Type EPSM in Generator Exciter(EX2100) System. Developed EPSM has the compatibility with the existing product in the structure and shape and electrical feature and so on, but it has a much improved capacity and reliability in comparison with origin company product. this paper, to improve these functions, put emphasis on protection, monitoring, power capacity increase(over 120%), an enlarged scale of input voltage supply, AC/DC dual voltage use and so on. After manufacturing product localization, it was carried out several tests for the performance and reliability verification of developed product. These tests were performed in Authorized Inspection Agency(KTL) and field application test and maker self-test were additionally performed. Finally, the results of all tests were "success".

공작기계 구조물의 정ㆍ동강성 평가방법에 관한 연구 (A Comparative Study on the Static and Dynamic Stiffness Evaluation Methods of Machine Tool Structure)

  • 최영휴;강영진;김태형;박보선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.46-50
    • /
    • 2002
  • In other to evaluate the static and dynamic stiffness of machine tool structure, the accuracy and error from experimental methods are studied in this paper. The F.E.M., impulse tests and exciter tests are performed for the general simple structure whose exact solution can be obtained. So that the parameter and dynamic compliance can be got. From the result, the variation of natural frequency can be verified from the static preload. Further more the relationship of identify and difference for compliance and direction is presented in the exciting direction and measurement direction.

  • PDF

Performance analysis of a 746 W HTS generator equipped with 70 A class contactless superconducting field exciter

  • Chae, Yoon Seok;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.1-6
    • /
    • 2020
  • This paper presents the analysis results on the electrical output performance characteristics of a 746 W high temperature superconducting generator (HTSG). The HTS field winding is charged by non-contact excitation method, i.e., contactless superconducting field exciter (CSFE) which is originated by rotary flux pump based on permanent magnet. In this paper, the preliminary current charging test was carried out using a 70 A CSFE to evaluate the performance of field exciter and analyze its non-contact excitation characteristics for the full-scale HTS field winding of the 746 W HTSG. First, the various contactless current-charging tests were conducted using assembly with HTS field winding and CSFE. Then, in order to estimate the output power performance characteristics of the 746 W HTSG, finite element analysis was conducted based on field excitation information which is experimentally measured under various operating conditions. Finally, the electrical output characteristics in no-load and load models were simulated by two-dimensional transient solver in ANSYS electromagnetics 19.0 release.

자기 베어링 시스템을 가진기로 이용한 스퀴즈 필름 댐퍼의 동특성 계수 규명 (Identification of Dynamic Characteristics of Squeeze Film Damper Using Active Magnetic Bearing System as an Exciter)

  • 김근주;이종원
    • 한국소음진동공학회논문집
    • /
    • 제13권7호
    • /
    • pp.508-516
    • /
    • 2003
  • The dynamic characteristics of an ell-lubricated, short squeeze film damper (SFD) with a central feeding groove are derived based on a theoretical analysis considering the effect of a groove, and identified experimentally using an Active Magnetic Bearing (AMB) system as an exciter. In order to get the theoretical solution, the fluid film forces of the grooved SFD are analytically derived so that the dynamic coefficients of the SFD can be expressed in terms of its design parameters. For the experimental validation of the analysis, a test rig using an AMB as an exciter is proposed. As an exciter. the AMB represents a mechatronic device to levitate and position the test Journal without any mechanical contact, to generate relative motions of the Journal inside the tested SFD and to measure the generated displacements during experiments with fairly high accuracy. Using this test rig, experiments are extensively conducted with various values of clearance, which Is one of the most important design parameters. in order to investigate its effect on the dynamic characteristics and the performance of the SFD. Damping and Inertia coefficients of the SFD that are experimentally Identified are compared with the analytical results to demonstrate the effectiveness of the applied analysis. It Is also shown that the AMB is an ideal device for tests of SFDs.

발전기/제어계 특성시험을 통한 제주한림 S/T 모델정수 결정과 전압제어특성 평가 (Cheju Hanlim S/T Model Parameter Determination and Assessment of Voltage Control Loop on the Characteristic Tests of Generator/Excitation System)

  • 김동준;문영환;이금진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.147-149
    • /
    • 1999
  • This paper deals with the determination of generator/exciter model parameters for a Cheju Hanlim steam turbine unit. Using the recorded data from the generator characteristic tests, the model parameters have been derived and verified by comparing the simulation results and recorded data. In addition to it, the closed-loop performance of voltage control on no-load condition has been assessed in the frequency domain by taking advantage of derived generator/exciter model parameters.

  • PDF

사장교 케이블 동특성 평가를 위한 케이블 가진시스템 개발 (Development of Cable Excitation System for Evaluating Dynamic Characteristics of Stay Cables)

  • 김남식;정운;서주원;안상섭
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.71-79
    • /
    • 2003
  • 사장교에서 케이블은 교량 전체에 있어서 매우 중요한 요소이다. 차량, 바람 혹은 풍우에 의한 케이블의 진동은 교량의 안전성과 사용성을 감소시키는 주요 원인이 되어왔으며 이러한 문제를 해결하는 효과적인 방법중의 하나는 케이블 댐퍼를 설치하는 것이다. 이 케이블 댐퍼를 최적으로 설계하기 위해서는 케이블의 동특성을 정확하게 평가해야 하며 케이블 동특성치를 얻기 위해서는 정확한 가진이 필요하다. 따라서 본 연구에서는 케이블 가진시스템을 개발하고 성능을 평가하기 위해 케이블 가진시스템의 운동방정식을 유도하였으며, 케이블 가진기를 케이블 모형에 설치하여 정현진동실험과 공진진동실험을 수행하여 케이블의 동특성을 효과적으로 구하였다.

자기베어링 시스템을 가진기로 이용한 스퀴즈 필름 댐퍼의 동강성 계수 규명 (Identification of Dynamic Stiffness of Squeeze Film Damper using Active Magnetic Bearing System as an Exciter)

  • 김근주;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.381-387
    • /
    • 2002
  • In this work, the dynamic characteristics of an oil-lubricated, short SFD with a central feeding groove are derived based on a theoretical analysis considering the effect of a groove. The validity of the analysis is investigated experimentally using an Active Magnetic Bearing (AMB) system as an exciter. For the theoretical solution, the fluid film forces of a grooved SFD are analytically derived so that the dynamic coefficients of a SFD are expressed in terms of its design parameters. For the experimental validation of the analysis, a test rig using AMB as an exciter is proposed to identify the dynamic characteristics of a short SFD with a central groove. As an exciter, the AMB represents a mechatronic device to levitate and position the test journal without any mechanical contact, to generate relative motions of the journal inside the tested SFD and to measure the generated displacements during experiments with fairly high accuracy. Using this test rig, experiments are extensively conducted with different clearance, which is one of the most important design parameters, in order to investigate its effect on the dynamic characteristics and the performance of SFDs. Damping and inertia coefficients of the SFD that are experimentally identified are compared with the analytical results to demonstrate the effectiveness of the analysis. It is also shown that AMB is an ideal device for tests of SFDs.

  • PDF

수직발사 유도탄의 진동시험에서 유도탄 장착방향의 영향에 대한 연구 (Study on the Effects of the Mounting Direction of Vertically-launched Missiles in Vibration Tests)

  • 이호준;김기언
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.218-225
    • /
    • 2013
  • Vertically-launched missiles are supported as erected vertically in the vertical launching system of warship, and they should be mounted in the same way when vibration-tested. However, mounting missiles vertically makes a fixture, which is a supporting structure, bulky and heavy so requiring a high-performance exciter. Mounting missiles as laid down horizontally in a vibration test is economical regarding fixture manufacturing and exciter performance, but it makes test results incorrect because the different mounting direction has effects on the test results. A bending moment due to missiles' weight happens to missiles, and resilient mounts, which support missiles in the vertical launch system, deflect differently from the real situation because of the static deflection of these mounts due to missiles' weight. If the resilient mounts supporting missiles have nonlinear force-deflection characteristics, vibration test results become more different from the true results. This paper proposes to support missiles with an additional resilient mount such as a bunge code in order to solve those problems coming from mounting vertically-launched missiles as laid down horizontally in vibration tests. The proposed approach enables to obtain the same test results as in their actual mounting condition even though vertically-launched missiles are mounted in a different direction.

개인용 컴퓨터와 고속 이더넷을 이용한 다기 다모선 전력 시스템 실시간 시뮬레이터 개발에 관한 연구 (Development of an Real-time Multi-machine Power System Simulator using Personal Computers and Fast Ethernet)

  • 김중문
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.63-68
    • /
    • 2009
  • As the complexity of the power system becomes higher, tests of the new devices, such as exciter and PCS(Power Conversion System) of the distributed generation sources, in the real operating condition are more important. However tests of the unverified devices in the real power system may cause hazardous malfunction of the system. In order to avoid this problem, power devices may be tested with the real-time simulators instead of the real power system. This paper presents an real-time multi machine power system simulator using PCs(Personal Computer) and Fast Ethernet. Developed real-time simulator performs the electro-mechanical dynamic simulation of multi-machine power system by the network distributed computing technique. Because the simulator consists of usual PCs and Fast Ethernet, it is possible to make up a simulation system very cheaper than the conventional real-time simulator which consists of dedicated expensive hardware devices. The performance of the developed simulator is tested and verified with the scaled model excitation system. The test which adjust the control parameters of the exciter is performed with the well-known New England 10 generator 39 bus sample power system.