• Title/Summary/Keyword: Exact test

Search Result 1,485, Processing Time 0.026 seconds

Effects of Emotional Intelligence Improvement Program for New graduate Nurses on Emotional Intelligence and Job Stress -Mixed Methods Research- (신규간호사를 위한 감성지능 향상프로그램이 감성지능과 직무스트레스에 미치는 효과 -혼합연구설계-)

  • Moon, Eun Kyung;Lee, Oi Sun;Kim, Mi Jung;Sim, Bong Hi
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.419-431
    • /
    • 2022
  • This study was conducted to develop and test the effects of an emotional intelligence program for new nurses. The study design was a mixed method research. Participants were 29(intervention group: 15, control group: 14) new nurse. The emotional intelligence improvement program was conducted once a week for a total of 8 weeks (20 hours).The emotional intelligence program was provided for 8 weeks (20 hours). Quantitative data were analyzed using Chi-square, Fisher's exact test, t-test, repeated measure ANOVA with SPSS/WIN 18.0. Qualitative data were analyzed using content analysis. Quantitative results showed that emotional intelligence, Job stress were no significantly better in the experimental group compared to the control group. According to the qualitative results, the new nurse experienced improvement in emotional intelligence, empowerment, a reduction in stress, Changed from 'alone' to 'us', and as well as I dream of my future self after participation in the emotional intelligence program. A study to apply the emotional intelligence improvement program to nurses at various times and to verify its effectivene.

Perceptions and attitudes of dental hygienists toward radiation safety and protection in the Republic of Korea

  • Yun, Kwidug;Lee, Kyung-Min;An, Seo-Young;Yoon, Suk-Ja;Jeong, Ho-Gul;Lee, Jae-Seo
    • International Journal of Oral Biology
    • /
    • v.46 no.4
    • /
    • pp.168-175
    • /
    • 2021
  • To investigate the perceptions and attitudes of dental hygienists toward radiation safety management in Korea. A total of 800 dental hygienists were randomly selected for an anonymous survey, and 203 of them participated. The questionnaire items included the following: sex, career period, type of installed radiographic equipment, recognition of the diagnostic reference level (DRL), participation in radiation safety education, and attitudes toward radiation protection for both patients and dental hygienists. The participants were divided into two groups according to their years of experience (< 10 years versus ≥ 10 years). The difference between the groups was investigated according to frequency distribution. Fisher's exact test or Pearson's chi-square (𝛘2) test was used as appropriate. A regression analysis was performed to investigate the impact of wearing a thyroid collar for personnel protection during patient radiation exposure. The types of installed radiographic equipment included panoramic radiography (96.1%), cephalometric radiography (76.9%), intraoral radiography (72.9%), and cone-beam computed tomography (69.5%). Significant differences were observed in the learning pathway for the DRL (Fisher's exact test, p < 0.05), satisfaction with radiation safety education (Pearson's 𝛘2 test = 5.3975, Pr = 0.02), and use of personnel radiation monitoring systems (Pearson's 𝛘2 test = 18.1233, Pr = 0.000) between the groups. Significant differences were also observed in personnel protection using a thyroid collar and patient protection during panoramic radiography (odds ratio = 14.2). Dental hygienists with more than 10 years of experience were more satisfied with radiation safety education and more interested in radiation monitoring. Considering career experience, customized, continuous, and effective radiation safety management education should be provided.

Study on the equivalent test equipment for AC Motor (전력회생형 부하시험장치에 관한 연구)

  • 김현수;김한종;허재영;최창식;이제필;장철호;정종태
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.295-298
    • /
    • 1997
  • In large system, design margin makes relatively price higher. So, optimal design through exact analysis of thermal behavior is needed. In this paper, we propose the equivalent load test facility using two inverter & converter system and inductors. Applying actual electrical profiles for motor drive, thermal characteristics of power converter fed AC motor drive are obtained, and the results are compared with simulation results.

  • PDF

ROBUST UNIT ROOT TESTS FOR SEASONAL AUTOREGRESSIVE PROCESS

  • Oh, Yu-Jin;So, Beong-Soo
    • Journal of the Korean Statistical Society
    • /
    • v.33 no.2
    • /
    • pp.149-157
    • /
    • 2004
  • The stationarity is one of the most important properties of a time series. We propose robust sign tests for seasonal autoregressive processes to determine whether or not a time series is stationary. The proposed tests are robust to the outliers and the heteroscedastic errors, and they have an exact binomial null distribution regardless of the period of seasonality and types of median adjustments. A Monte-Carlo simulation shows that the sign test is locally more powerful than the tests based on ordinary least squares estimator (OLSE) for heavy-tailed and/or heteroscedastic error distributions.

ROBUST UNIT ROOT TESTS FOR SEASONAL AUTOREGRESSIVE PROCESS

  • Oh, Yu-Jin;So, Beong-Soo
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2003.05a
    • /
    • pp.281-286
    • /
    • 2003
  • The stationarity is one of the most important properties of a time series. We propose robust sign tests for seasonal autoregressive process to determine whether or not a time series is stationary. The tests have an exact binomial null distribution and are robust to the outliers and the heteroscedastic errors. Monte-Carlo simulation shows that the sign test is locally more powerful than the OLSE-based tests for heavy-tailed and/or heteroscedastic error distributions.

  • PDF

3D-ESPI 시스템을 이용하여 결정된 응력집중계수가 피로수명에 미치는 영향에 관한 연구

  • Kim, Seong-Chan
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • v.12
    • /
    • pp.36-43
    • /
    • 2003
  • Fatigue life estimation by the theoretical stress concentration factors are, in general, considerably different from test results. And in calculating stress concentration factor, it is very difficult to consider actual geometry and material property which are the notch shapes, imperfections or defects of materials such as porosities inclusions and casting defects, etc. Therefore, the paper deals with the experimental method to find out the more exact stress concentration factors by measuring the strain distributions on each specimen by 3D-ESPI(Electronic Speckle Pattern Interferometry) System. Then the fatigue lives are compared between theoretical calculations using stress concentration factors determined by 3D-ESPI system and fatigue test results

  • PDF

SOME EXPLICIT SOLUTIONS OF NONLINEAR EVOLUTION EQUATIONS

  • Kim, Hyunsoo;Lee, Youho
    • Honam Mathematical Journal
    • /
    • v.39 no.1
    • /
    • pp.27-40
    • /
    • 2017
  • In this paper, we construct exact traveling wave solutions of various kind of partial differential equations arising in mathematical science by the system technique. Further, the $Painlev{\acute{e}}$ test is employed to investigate the integrability of the considered equations. In particular, we describe the behaviors of the obtained solutions under certain constraints.

Optimal Test Condition by Ultrasonic Simulation (초음파 시뮬레이션을 이용한 최적의 탐상조건)

  • Huh, Sun-Chul;Park, Young-Chul;Boo, Myung-Hwan;Kang, Jung-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.45-54
    • /
    • 1999
  • Non destructive test is applied to revise mechanical strength and assume material strength or defect of material, equipment and structure, instead of fracture test. Especially, ultrasonic test has the characteristics such as an excellent permeability high-sensitiveness to fine defect and an almost exact measurement for position, size and direction of inner defect which differ from other non destructive tests. In this study, the program is developed to evaluate optimal testing condition, to distinguish obstacle echo and defect position. This program on the basic of Ray-Tracing model shows generation and processing of ultrasonic pulse. The simulation is compared with testing in the 3 cases of an oblique angle transducer like $45^{\circ},\;60^{\circ}\;and\;70^{\circ}$. The test result for all conditions is well compared with simulation result when relative not is within $0.1{\sim}7.2%$. And the course of several echos is simply assumed through simulation.

  • PDF

A Study on Test for NBU Class (NBU CLASS에 관한 검정법 연구)

  • 김환중
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.2
    • /
    • pp.395-406
    • /
    • 2003
  • In this thesis, we propose a test statistic for testing exponentiality against NBU alternatives. Our test statistics is based on a linear function of the order statistics and is readily applied in the case of small sample as well as large sample. The exact and asymptotic distribution of the test statistics is derived and asymptotic efficiencies are studied. Our new test is easier to compute and performs better for several alternatives than test of Hollander and Proschan(1972).

A Study on Evaluation of Crack Opening Point in Al 2024-T3 Material (Al 2024-T3재의 Crack Opening Point의 평가에 관한 연구)

  • Choi, Byung-Ki;Jang, Kyeung-Cheun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.16-20
    • /
    • 2004
  • This paper aims to analyze fatigue fracture mechnisms with high strength aluminum alloys, which are widely used in vehicles or airplanes to prevent accidents. Usefulness of the crack opening point was proposed by using an effective stress intensity facor when evaluating the fatigue crack propagaion rate. Therefore an exact crack opening ratio can be measured for a more exact fatigue crack propagation rate. It is found that the fatigue crack propagation rate was valid within the range of experimentation as an effective stress intensity factor. Summarizing the results are as follows in this paper ; (1) It is found that the value of the crack opening ratio is constant at the rear of the specimen, U'=0.25 at the crack mouth and U'=0.45 at the crack tip, respectively regardless of the stress ratio. (2) The crack opening ratio is different according to measurement locations. The crack opening ratio value was measured at the crack mouth by a clip gage or measured behind the specimen by a strain gage. It is found that the crack opening ratio value is more accurate that any other measuring test for evaluating the crack propagation ratio test by effective stress intensity factor.