• 제목/요약/키워드: Evaluation of seismic performance

검색결과 917건 처리시간 0.024초

철근콘크리트 전단벽식 건물의 내진성능지수 (Seismic Performance Index of Reinforced Concrete Shear Wall Buildings)

  • 권영웅`;김민수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.148-151
    • /
    • 2003
  • This paper concerns the seismic performance index of highrise reinforced concrete shear wall buildings assessed by FEMA 273 and ATC-40 provisions. The applied buildings are 10 to 35 stories and the evaluation level is life safety level. The seismic performance index results of $1^{st}$ and $2^{nd}$ evaluations are as follows; (equation omitted)

  • PDF

Evaluation of Seismic performance of RC setback frames

  • Habibi, Alireza;Vahed, Meisam;Asadi, Keyvan
    • Structural Engineering and Mechanics
    • /
    • 제66권5호
    • /
    • pp.609-619
    • /
    • 2018
  • When the irregularities occurred in buildings, affect their seismic performance. This paper has focused on one of the types of irregularities at the height that named setback in elevation. For this purpose, several multistorey Reinforced Concrete Moment Resisting Frames (RCMRFs) with different types of setbacks were designed according to new edition of Iranian seismic code. The nonlinear time history analysis was performed to predict the seismic performance of frames subjected to seven input ground motions. The assessment of the seismic performance was done considering both global and local criteria. Results showed that the current edition of Iranian seismic code needs to be modified in order to improve the seismic behaviour of reinforced concrete moment resisting setback buildings. It was also shown that the maximum damages happen at the elements located in the vicinity of the setbacks. Therefore, it is necessary to strengthen these elements by appropriate modification of Iranian seismic code.

진동대 실험을 통한 수계 소화설비의 지진응답평가에 관한 연구 (Seismic Response Estimation of Water Extinguishing Facilities using Shaking Table Tests)

  • 남민준;박승희;김동준;최준성
    • 한국지진공학회논문집
    • /
    • 제16권4호
    • /
    • pp.9-18
    • /
    • 2012
  • 본 연구에서는 진동대 실험을 통한 수계형 소화설비의 내진성능평가를 실시하였다. 실험에 사용된 수계형 소화설비 시설에는 일반 배관, 내진형 배관, 펌프 등 이다. 그리고 수계형 소화설비 시설의 동적거통특성을 파악하기 위하여 El-Centro 지진파 50%, 70%, 100%, 120% 수준의 가진을 가하였다. 그 결과, 내진형 설비보다 일반형 설비에서 변위 응답과 가속도 응답이 큰 것으로 보아 내진형 설비가 일반설비에 비해 내진성능이 우수하다는 것을 알 수 있었다. 또한, 가진 수준별 가속도 응답스펙트럼을 통하여 일반형 시설과 내진형 시설의 성능 평가뿐만 아니라 작은 규모의 지진에서도 일반형 설비의 파괴가 일어날 수 있다는 것을 알 수 있었다. 본 연구를 통해 수계 소화설비의 내진성능을 평가 할 수 있었고 수계 소화설비의 내진성능 기준을 검증할 수 있었다.

면진 원전 면진-비면진구간 연결 배관의 내진성능 평가 (Seismic Performance Evaluation of Piping System Crossing the Isolation Interface in Seismically Isolated NPP)

  • 함대기;박준희;최인길
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.141-150
    • /
    • 2014
  • A methodology to evaluate the seismic performance of interface piping systems that cross the isolation interface in the seismically isolated nuclear power plant (NPP) was developed. The developed methodology was applied to the safety-related interface piping system to demonstrate the seismic performance of the target piping system. Not only the seismic performance for the design level earthquakes but also the performance for the beyond design level earthquakes were evaluated. Two artificial seismic ground input motions which were matched to the design response spectra and two historical earthquake ground motions were used for the seismic analysis of piping system. The preliminary performance evaluation results show that the excessive relative displacements can occur in the seismically isolated piping system. If the input ground motion contained relatively high energy in the low frequency region, we could find that the stress response of the piping system exceed the allowable stress level even though the intensity of the input ground motion is equal to the design level earthquake. The structural responses and seismic performances of piping system were varied sensitively with respect to the intensities and frequency contents of input ground motions. Therefore, for the application of isolation system to NPPs and the verification of the safety of piping system, the seismic performance of the piping system subjected to the earthquake at the target NPP site should be evaluated firstly.

층간변위를 기반으로 한 다층구조물의 내전성능 평가를 위한 역량스펙트럼법의 개발 (Capacity Spectrum Method for Seismic Performance Evaluation of Multi-Story Building Based on the Story Drift)

  • 김선필;김두기;곽효경;고성혁;서형열
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.205-210
    • /
    • 2007
  • The existing capacity spectrum method (CSM) is based on the displacement based approach for seismic performance and evaluation. Currently, in the domestic and overseas standard concerning seismic design, the CSM to obtain capacity spectrum from capacity curve and demand spectrum from elastic response spectrum is presented. In the multistory building, collapse is affected more by drift than by displacement, but the existing CSM does not work for story drift. Therefore, this paper proposes an improved CSM to estimate story drift of structures through seismic performance and evaluation. It uses the ductility factor in the A-T domain to obtain constant-ductility response spectrum from earthquake response of inelastic system using the drift and capacity curve from capacity analysis of structure.

  • PDF

지하철 1~4호선 내진성능 평가절차 및 보강방향 (Seismic Performance Evaluation Procedure and Reinforcement Direction of Subway Lines 1~4)

  • 장원락;정지승
    • 문화기술의 융합
    • /
    • 제5권4호
    • /
    • pp.439-444
    • /
    • 2019
  • 본 논문에서는 도시철도 내진설계 기준에 의거하여 내진설계가 되지 않은 기존 구조물에 대해서 2010년 4월부터 2013년 10월까지 시행된 지하철 1~4호선에 대해 내진성능 평가방안을 연구하였고, 2012년 12월부터 2018년 12월까지 시행한 내진성능 보강공사 실시설계를 통하여 내진보강이 필요한 시설물에 대한 내진성능 보강방향에 대해 정리하였다. 평가결과 1~4호선 141.5km 중 53.2km(총 사업비 3,220억원)가 내진보강이 필요한 것으로 검토 되었으며, 최종적으로 2020년까지 지진규모 6.5에 견딜 수 있게 내진율 100% 확보를 목표하고 있다. 본 논문은 향후 도시철도의 내진성능을 평가하고 보강하기 위한 기초 연구자료로 활용될 수 있을 것으로 판단된다.

중층 종합병원 건물의 내진성능평가 (Seismic Performance Evaluation of a Mid-rise General Hospital Building)

  • 김태완;추유림;김승래
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.245-254
    • /
    • 2017
  • The building which are essential for disaster recovery is classified as a special seismic use group. Especially, achievement of seismic performance is very important for the hospital, so the hospital should be able to maintain its function during and right after an earthquake without significant damage on both structural and non-structural elements. Therefore, this study aimed at checking the seismic performance of a hospital building, but which was limited to structural elements. For the goal, a plan with a configuration of general hospitals in Korea was selected and designed by two different seismic-force-resisting systems. In analytical modeling, the shear behavior of the wall was represented by three inelastic properties as well as elastic. Nonlinear dynamic analyses were conducted to evaluate the performance of structural members. The result showed that the performance of shear walls in the hospital buildings was not satisfied regardless of the seismic-force-resisting systems, while the demands on the beams and columns did not exceed the capacities. This is the result of only considering the shear of the wall as the force-controlled action. When the shear of the wall was modeled as inelastic, the walls were yielded in shear, and as the result, the demands for frames were increased. However, the increase did not exceed the capacities of the frames members. Consequently, since the performance of walls is significant to determine the seismic performance of a hospital building, it will be essential to establish a definite method of modeling shear behavior of walls and judging their performance.

비선형 동적해석을 이용한 소규모 필로티형 철근콘크리트 건축물의 내진성능평가 (Seismic Performance Evaluation of Small-size Pilloti-type Reinforced Concrete Buildings using Nonlinear Dynamic Analysis)

  • 유창환;김태완;추유림
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.191-199
    • /
    • 2016
  • Piloti-type building is one of typical vertical atypical buildings. These buildings can fail by weak-story or flexible-story mechanism on the first story. They should be designed by taking into account the special seismic load, but those less than six stories are not required to confirm the seismic performance from structural engineers in Korea. For this reason, small-size pilloti-type RC buildings need to be checked for seismic performance. Based on this background, this study performed nonlinear dynamic analysis using the PERFORM-3D for small-size pilloti-type RC buildings and assessed their seismic performance. Examples are two through four story buildings with and without walls in the first story. The walls and columns in the first story satisfied the target performance in the basic of flexural behavior due to quite a large size and reinforcement. However, wall shear demands exceed shear strength in some buildings. When designed for KBC2009, wall shear strength exceed shear demand in some buildings, but still does not in others. Consequently, wall shear must be carefully checked in both existing and new small-size pilloti-type RC buildings.

내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가 (Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment)

  • 정란;이정우;박태원
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.721-728
    • /
    • 2006
  • 지진은 구조물에 막대한 피해를 발생시키는 것으로 보고되고 있으나, 우리나라에 내진설계규정이 도입되기 전인 1988년 이전에 설계된 건물은 이에 대한 대책이 없다. 특히 공동주택의 경우 지진저항요소가 없는 구조물이 다수 있는 것으로 조사되었다. 이러한 구조물에 대하여 내진성능의 정도를 파악하고, 성능지수가 부족한 구조물에 대해서는 적절한 보강이 이루어져야 할 것이다. 본 연구에서는 이전의 연구에서 범용 구조해석 프로그램인 MIDAS를 이용하여 모델 구조물의 내진성능을 평가하여 얻어진 내진성능의 부족함을 기초로 5층 규모의 철근콘크리트 벽식 구조물에 상사법칙을 적용하고, 진동대 실험을 수행하여 국내외 규준에 의한 모델 구조물의 내진성능을 평가하였다. 진동대 실험의 경우 실험의 공간적 제약으로 인하여 원형 구조물에 대한 실험을 할 수 없어, 구조물의 원형크기를 상사법칙에 의하여 필요한 규모로 축소하여 제작하였다. 성능수준을 평가해 본 결과 내진설계가 수행되지 않은 구조물은 PGA 등급 0.2g의 지진에 대하여 사용한계수준의 내진성능을 나타내었으며 허용층간변위를 평가해 본 결과 0.2g의 지진등급까지만 허용한계수준의 층간변위를 나타내어 내진성능에 대한 보강이 필요할 것으로 판단되었다.

콘크리트 충전 강교각의 내진 성능 (The Seismic Performance for Concrete-filled Steel Piers)

  • 정지만;장승필;인성빈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF