• Title/Summary/Keyword: Evaluation of image quality

Search Result 961, Processing Time 0.034 seconds

Verification of Gated Radiation Therapy: Dosimetric Impact of Residual Motion (여닫이형 방사선 치료의 검증: 잔여 움직임의 선량적 영향)

  • Yeo, Inhwan;Jung, Jae Won
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.128-138
    • /
    • 2014
  • In gated radiation therapy (gRT), due to residual motion, beam delivery is intended to irradiate not only the true extent of disease, but also neighboring normal tissues. It is desired that the delivery covers the true extent (i.e. clinical target volume or CTV) as a minimum, although target moves under dose delivery. The objectives of our study are to validate if the intended dose is surely delivered to the true target in gRT and to quantitatively understand the trend of dose delivery on it and neighboring normal tissues when gating window (GW), motion amplitude (MA), and CTV size changes. To fulfill the objectives, experimental and computational studies have been designed and performed. A custom-made phantom with rectangle- and pyramid-shaped targets (CTVs) on a moving platform was scanned for four-dimensional imaging. Various GWs were selected and image integration was performed to generate targets (internal target volume or ITV) for planning that included the CTVs and internal margins (IM). The planning was done conventionally for the rectangle target and IMRT optimization was done for the pyramid target. Dose evaluation was then performed on a diode array aligned perpendicularly to the gated beams through measurements and computational modeling of dose delivery under motion. This study has quantitatively demonstrated and analytically interpreted the impact of residual motion including penumbral broadening for both targets, perturbed but secured dose coverage on the CTV, and significant doses delivered in the neighboring normal tissues. Dose volume histogram analyses also demonstrated and interpreted the trend of dose coverage: for ITV, it increased as GW or MA decreased or CTV size increased; for IM, it increased as GW or MA decreased; for the neighboring normal tissue, opposite trend to that of IM was observed. This study has provided a clear understanding on the impact of the residual motion and proved that if breathing is reproducible gRT is secure despite discontinuous delivery and target motion. The procedures and computational model can be used for commissioning, routine quality assurance, and patient-specific validation of gRT. More work needs to be done for patient-specific dose reconstruction on CT images.

Study on the Breast Tissue Uptake according to Body Temperature on Molecular Breast Imaging (Molecular Breast Imaging 검사 시 체온 변화에 따른 유방 섭취율에 관한 고찰)

  • Kim, Ji Hyun;Baek, Song Ee;Oh, Shin Hyun;Ham, Jun Cheol;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.20-24
    • /
    • 2019
  • Purpose Molecular Breast Imaging (MBI) scan is used in nuclear medicine, for which $^{99m}Tc-sestaMIBI$ is administered by intravenous injection. However, the breast uptake rate of $^{99m}Tc-sestaMIBI$ is less than 1% of the total dose administered, relying on blood flow conditions of organs. The purpose of this study is to evaluate the impact of changes to body temperature on the uptake of $^{99m}Tc-sestaMIBI$ in breast tissue. Materials and Methods We investigated 30 breast cancer patients who performed more than one follow-up MBI scan. All scans were acquired by Discovery 750B (Genral Electric Healthcare, USA). $^{99m}Tc-sestaMIBI$ injected with 740 MBq (20 mCi), after 60 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. The follow-up examination was then classified into 15 body temperature control group and 15 body temperature non-control group, and gained breast image in the same way as before. The breast uptake rate was analyzed in the MLO View of the opposite side of the lesion, and blind images were evaluated. Results The breast uptake rate increased by 30.31% in the body temperature control group and it was statistically significant(P<0.05), and 0.96% in the body temperature non-control group, and it was not statistically significant(P=0.955). There was a significant difference in the uptake rate between the body temperature control and the non-control group of P value of 0.01. Evaluation of blind images showed significant results in terms of the quality of the images. Conclusion Increased breast tissue uptake was observed when the subject was kept warm. When the body temperature was raised after injection, dilation of the peripheral blood vessels can be achieved. As a result, the blood flow became smooth and the breast uptake rate increased. In addition, an increase in breast tissue uptake will improve the quality of images.

Evaluation of Image Quality Using CT Attenuation Correction in SPECT/CT (SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가)

  • Cho, Sung Wook;Kim, Gye Hwan;Sung, Yong Joon;Lee, Hyung Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.78-83
    • /
    • 2013
  • Purpose: SPECT/CT, a combination of SPECT and CT, is capable of expressing the results of attenuation correction on images biased by automatic program. As a result, this research evaluates the usefulness of images with CT attenuation correction, using various phantoms and images of patients. Materials and Methods: From July of 2012 to September of 2012, this research was conducted on the contrast, spatial resolution, and images of patients. We studied the contrast with IEC body phantom and Jaszczak phantom, while the spatial resolution was evaluated with NEMA triple line phantom. Further, a comparative study was carried out on the quality of the images, on the difference between the images before and after the CT attenuation correction. Results: Compared the differences between the contrast before and after the CT attenuation correction in IEC body phantom. The contrast was improved by 33.6% at minimum, 89.8% at maximum. In case of Jaszczak Phantom, the contrast was enhanced by 9.9% at minimum, 27.8% at maximum. In NEMA Triple line phantom, the resolution was raised by 4.5% in average: 4.4% in horizontal, 4.5% in vertical. In Anthropomorphic Torso Phantom, the perfusion score of the interior wall with the most severe attenuation was measured to be 29.4%. In the experiment carried out on myocardial perfusion SPECT/CT patients, 9% improvement was discovered in the interior wall, where the most dramatic attenuation occurred, after the CT attenuation correction. Conclusion: SPECT/CT proved its clinical usefulness by enabling the acquisition of images with enhanced contrast and spatial resolution compare to the ones resulted from SPECT.

  • PDF

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position (Supine 자세에서 Shoulder oblique촬영시 Tube angle 변화에 따른 Shoulder joint에 대한 고찰)

  • Seo, Jae-Hyun;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.109-114
    • /
    • 2008
  • There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were $1.10{\pm}0.54$ at $25^{\circ}$, $2.50{\pm}0.50$ at 30^{\circ}$, $2.85{\pm}0.36$ at $35^{\circ}$ and $2.33{\pm}0.47$ at $40^{\circ}$, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at $35^{\circ}$, $30^{\circ}$ and $40^{\circ}$ with the almost same score. However, the degree of distortion at $40^{\circ}$ was more severe than that at $30^{\circ}$. Ultimately, $30-35^{\circ}$ views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  • PDF

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

A New Item Recommendation Procedure Using Preference Boundary

  • Kim, Hyea-Kyeong;Jang, Moon-Kyoung;Kim, Jae-Kyeong;Cho, Yoon-Ho
    • Asia pacific journal of information systems
    • /
    • v.20 no.1
    • /
    • pp.81-99
    • /
    • 2010
  • Lately, in consumers' markets the number of new items is rapidly increasing at an overwhelming rate while consumers have limited access to information about those new products in making a sensible, well-informed purchase. Therefore, item providers and customers need a system which recommends right items to right customers. Also, whenever new items are released, for instance, the recommender system specializing in new items can help item providers locate and identify potential customers. Currently, new items are being added to an existing system without being specially noted to consumers, making it difficult for consumers to identify and evaluate new products introduced in the markets. Most of previous approaches for recommender systems have to rely on the usage history of customers. For new items, this content-based (CB) approach is simply not available for the system to recommend those new items to potential consumers. Although collaborative filtering (CF) approach is not directly applicable to solve the new item problem, it would be a good idea to use the basic principle of CF which identifies similar customers, i,e. neighbors, and recommend items to those customers who have liked the similar items in the past. This research aims to suggest a hybrid recommendation procedure based on the preference boundary of target customer. We suggest the hybrid recommendation procedure using the preference boundary in the feature space for recommending new items only. The basic principle is that if a new item belongs within the preference boundary of a target customer, then it is evaluated to be preferred by the customer. Customers' preferences and characteristics of items including new items are represented in a feature space, and the scope or boundary of the target customer's preference is extended to those of neighbors'. The new item recommendation procedure consists of three steps. The first step is analyzing the profile of items, which are represented as k-dimensional feature values. The second step is to determine the representative point of the target customer's preference boundary, the centroid, based on a personal information set. To determine the centroid of preference boundary of a target customer, three algorithms are developed in this research: one is using the centroid of a target customer only (TC), the other is using centroid of a (dummy) big target customer that is composed of a target customer and his/her neighbors (BC), and another is using centroids of a target customer and his/her neighbors (NC). The third step is to determine the range of the preference boundary, the radius. The suggested algorithm Is using the average distance (AD) between the centroid and all purchased items. We test whether the CF-based approach to determine the centroid of the preference boundary improves the recommendation quality or not. For this purpose, we develop two hybrid algorithms, BC and NC, which use neighbors when deciding centroid of the preference boundary. To test the validity of hybrid algorithms, BC and NC, we developed CB-algorithm, TC, which uses target customers only. We measured effectiveness scores of suggested algorithms and compared them through a series of experiments with a set of real mobile image transaction data. We spilt the period between 1st June 2004 and 31st July and the period between 1st August and 31st August 2004 as a training set and a test set, respectively. The training set Is used to make the preference boundary, and the test set is used to evaluate the performance of the suggested hybrid recommendation procedure. The main aim of this research Is to compare the hybrid recommendation algorithm with the CB algorithm. To evaluate the performance of each algorithm, we compare the purchased new item list in test period with the recommended item list which is recommended by suggested algorithms. So we employ the evaluation metric to hit the ratio for evaluating our algorithms. The hit ratio is defined as the ratio of the hit set size to the recommended set size. The hit set size means the number of success of recommendations in our experiment, and the test set size means the number of purchased items during the test period. Experimental test result shows the hit ratio of BC and NC is bigger than that of TC. This means using neighbors Is more effective to recommend new items. That is hybrid algorithm using CF is more effective when recommending to consumers new items than the algorithm using only CB. The reason of the smaller hit ratio of BC than that of NC is that BC is defined as a dummy or virtual customer who purchased all items of target customers' and neighbors'. That is centroid of BC often shifts from that of TC, so it tends to reflect skewed characters of target customer. So the recommendation algorithm using NC shows the best hit ratio, because NC has sufficient information about target customers and their neighbors without damaging the information about the target customers.

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Anisotropy Measurement and Fiber Tracking of the White Matter by Using Diffusion Tensor MR Imaging: Influence of the Number of Diffusion-Sensitizing Gradient Direction (확산텐서 MR 영상을 이용한 백질의 비등방성 측정 및 백질섬유 트래킹: 확산경사자장의 방향수가 미치는 영향)

  • Jun, Woo-Sun;Hong, Sung-Woo;Lee, Jong-Sea;Kim, Sung-Hyun;Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Purpose : Recent development of diffusion tensor imaging enables the evaluation of the microstructural characteristics of the brain white matter. However, optimal imaging parameters for diffusion tensor imaging, particularly concerning the number of diffusion gradient direction, have not been studied thoroughly yet. The purpose of this study was to evaluate the influence of the number of diffusion gradient direction on the fiber tracking of the white matter. Materials and methods : 13 healthy volunteers (ten men and three women, mean age 30 years, age range 23-37 years) were included in this study. Diffusion tensor imaging was performed with different numbers of diffusion gradient direction as 6, 15, and 32, keeping the other imaging parameters constant. The imaging field ranged from 1 cm below the pons to 2-3 cm above the lateral ventricle, parallel to the anterior commissure-posterior commissure line. FA (fractional anisotropy) maps were created via image postprocessing, and then FA and its standard deviation were calculated in the genu and the splenium of the corpus callosum on each of FA maps. Fiber tracking of the corticospinal tract in the brain was performed and the number of the reconstructed fibers of the tract was measured. FA, standard deviation of FA and the number of the reconstructed fibers were compared statistically between the different diffusion gradient directions. Results : FA is not statistically significantly different between the different diffusion gradient directions. By increasing the number of diffusion gradient direction, standard deviation of FA decreased significantly, and the number of the reconstructed fibers increased significantly. Conclusion : The higher number of diffusion gradient direction provided better quality of fiber tracking.

  • PDF