• Title/Summary/Keyword: Evaluation of System Level

Search Result 2,629, Processing Time 0.029 seconds

Optical Spectroscopic Analysis of Muscle Spasticity for Low-Level Laser Therapy (LLLT)

  • Lee, Yeon-Ui;Lee, Sang-Kwan;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2011
  • Current therapeutic methods for suppressing muscle spasticity are intensive functional training, surgery, or pharmacological interventions. However, these methods have not been fully supported by confirmed efficacy due to the aggravation of the muscle spasticity in some patients. In this study, a combined system was developed to treat with a low-level laser and to monitor the region of the treatment using an optical spectroscopic probe that measures oxygen saturation and deoxygenation during low-level laser therapy (LLLT). The evaluation of the wavelength dependence for LLLT was performed using a Monte Carlo simulation and the results showed that the greatest amount of heat generation was seen in the deep tissue at ${\lambda}$ = 830 nm. In the oxy- and deoxygenation measurements during and after the treatment, oxygen-Hb concentration was significantly increased in the laser-irradiated group when compared to the control group. These findings suggest that LLLT using ${\lambda}$ = 830 nm may be of benefit in accelerating recovery of muscle spasticity. The combined system that we have developed can monitor the physiological condition of muscle spasticity during the laser treatment in real time and may also be applied to various myotonia conditions such as muscle fatigue, back-pain treatment/monitoring, and ulcer due to paralysis.

Audio-signal Transfer System Design and Evaluation based on Power Line Communication

  • Kim, Kwan-Kyu;Yeom, Keong-Tae;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.123-127
    • /
    • 2008
  • The paper is to solve the problem of existing audio signal transfer system which has a difficulties of system organization and the increase of additional install cost and unfriendly interior. To solve the existing system, we drew the new audio signal transfer system based on PLC and evaluated it. A transmitter and a receiver were designed using the PLC chip INT5500CS. An audio signal transfer system was configured with a CD player to which audio signals are sent from the transmitter and a speaker connected to the receiver. For performance evaluation of this system, a USBPre external sound card and Smaart Live 5 which is a PC-based sound measuring program were added. As a result of our experiment, the measured signal level is $2{\sim}3$ dB lower than reference signal, latency is 16.69 ms, and the specific character of coherency is bad in high frequency band. Otherwise, this system transmits and receives signals over 90 % in good condition as a result of measuring pink noise, frequency (1 kHz), and phase, magnitude. In view of the result so far achieved, the system designed this study has excellent performance, it resolves defect of existing audio signal transfer system.

Development of Practical Investigation and Diagnosis Model in Rural Villages - Development of Empirical Diagnostic Indicators through Delphi Method - (농촌마을의 실증적 조사·진단기법 개발(I) - 델파이 설문조사를 통한 실증진단지표의 개발 -)

  • Koo, Hee-Dong;Park, Mi-Ran;Kim, Dae-Sik
    • Journal of Korean Society of Rural Planning
    • /
    • v.27 no.2
    • /
    • pp.91-104
    • /
    • 2021
  • The purpose of this study is to develop the diagnostic indices system that can be applied to the evaluation of rural village level, because the indicators developed in many existing studies were mostly consisted of statistical data in higher level than rural villages as well as those were difficult to apply to rural village level empirically. In order to develop the empirical diagnostic indices system, which has 52 indices with 7 categories, this study not only classified the kind of rural village facility and the regional development project of government, but also surveyed the specialist opinion with Delphi method. Especially, this study standardized the all diagnostic indices with positive value to remove the indices with negative values. Finally, the results that the study applied the empirical diagnostic indices to the 15 sample villages of Jinan-gun and Cheongyang-gun showed that there was the applicability of the indices system in the village level.

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.

A Study on Evaluation and Improvement of Long-term Care Hospitals for Changing Long-term Care Hospital Fee System (요양병원형수가제 전환에 대한 요양병원의 평가 및 개선방안 연구)

  • Kim, Young-Bae
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.2
    • /
    • pp.105-117
    • /
    • 2011
  • The purpose of this study is to investigate evaluation and improvement of long-term care hospitals for changing long-term care hospitals fee system. Data were collected from 104 CEOs in nationwide long-term care hospitals using structured self-administered questionnaires during August 17 to 31, 2009. Major results of the empirical analysis are as follows; first, to change fixed sum medical fee per day caused to decline the level of geriatric service in 87% of CEOs. Second, 79% of CEOs were dissatisfied with changing fixed sum medical fee per day, and 47% of them were dissatisfied with graded fee for doctor and nurse management. Finally, they suggested that to specialize and to differentiate of long-term care hospitals will drive to improve long-term care hospitals function and to measure workforce based on rate of filled vacancies will increase efficiency and productivity of doctor and nurse management.

Development of a Computer Code for Low-and Intermediate-Level Radioactive Waste Disposal Safety Assessment

  • Park, J.W.;Kim, C.L.;Lee, E.Y.;Lee, Y.M.;Kang, C.H.;Zhou, W.;Kozak, M.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • A safety assessment code, called SAGE (Safety Assessment Groundwater Evaluation), has been developed to describe post-closure radionuclide releases and potential radiological doses for low- and intermediate-level radioactive waste (LILW) disposal in an engineered vault facility in Korea. The conceptual model implemented in the code is focused on the release of radionuclide from a gradually degrading engineered barrier system to an underlying unsaturated zone, thence to a saturated groundwater zone. The radionuclide transport equations are solved by spatially discretizing the disposal system into a series of compartments. Mass transfer between compartments is by diffusion/dispersion and advection. In all compartments, radionuclides ate decayed either as a single-member chain or as multi-member chains. The biosphere is represented as a set of steady-state, radionuclide-specific pathway dose conversion factors that are multiplied by the appropriate release rate from the far field for each pathway. The code has the capability to treat input parameters either deterministically or probabilistically. Parameter input is achieved through a user-friendly Graphical User Interface. An application is presented, which is compared against safety assessment results from the other computer codes, to benchmark the reliability of system-level conceptual modeling of the code.

Application of a Multi-Level Rotating Table for Strawberry Sorting and Packing (딸기 선별 및 포장작업의 자세개선을 위한 다층회전형 작업대 적용)

  • Park, Sung-Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.1
    • /
    • pp.97-102
    • /
    • 2011
  • This study was performed to design and develop an ergonomic equipment for strawberry sorting and packing in agricultural working environments. Potential risk of work related musculo-skeletal disorders associated with farm workers performing strawberry sorting and packing was analyzed through interviews, field surveys, work measurement, and working posture evaluation. For the evaluation of working posture, we used REBA, OWAS, and RULA assessment methods to identify multi-factorial risk factors. Based on the result of comprehensive assessment, a new concept of multi-level rotating table for strawberry sorting and packing was proposed to modify awkward working postures and improve the effectiveness of the farm work. Finally, the characteristics and effectiveness of new equipment was discussed in terms of improvements in productivity, safety, and subjective ratings of farm workers. The results of analysis showed that working conditions improved significantly.

Development of the Road Profiling System and Evaluation of Korean Roads Roughness Characteristics (도로면 측정 분석 시스템 개발 및 국내 도로면 특성평가 응용 연구)

  • 손성효;허승진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.192-197
    • /
    • 2003
  • The ‘AEIPR’(Accelerometer Established Inertial Profiling Reference) method has been applied to measure the road profile. The dynamic road profiling method using AEIPR has the advantages of cost effectiveness, measuring speed and relatively high reliability. However, it is required to improve the double integration algorithm to get the measurement results with the accuracy of hither level. In the first part of this paper, the effective double integration algorithm is suggested and the ‘Road Profiler’ software is developed on the basis of the algorithm. Road profiling tests are performed using the developed ‘Road Profiler’ system on the specially designed tracks for the durability tests and the various types of pubic roads. Test results are shown and evaluated by the international road evaluation indicies and classification.

(A) Study on the Priority Selection for business development of the Defense Education and Training System Based on Virtual Reality (가상현실 기반 국방 교육훈련체계 사업화 우선순위 선정에 관한 연구)

  • Lee, Se-Ho;Han, Seung-Jo
    • Journal of Digital Convergence
    • /
    • v.20 no.3
    • /
    • pp.201-209
    • /
    • 2022
  • In order for the military to review the introduction of virtual reality technology into various education and training systems and fully utilize it, it is important to reflect the characteristics of the technology and education system and to accurately identify and selectively apply the characteristics of commercialization. In this study, the evaluation criteria were selected through the Analitic Hierarchy Process (AHP) method for factors to be considered when commercializing a virtual reality-based education and training system, and the priorities of the projects were determined. Based on previous studies, an initial AHP model was constructed and the relative importance of six factors, including reality, was analyzed as the level 1 evaluation criteria. Next, for Level 2, each evaluation criterion was evaluated to confirm the importance of each of the 11 tasks in the six evaluation criteria, and priorities were selected for each task. As a result of the analysis, level 1 showed that reality and ripple had higher importance than other factors. As a result of evaluating the final relative importance, the priority was shown in the order of ① flight training, ② disaster training, ③ shooting Training, and ④ driving a vehicle. Based on the relative priorities determined in Levels 1 and 2 of the model presented in this study, the importance of each project necessary for final decision-making of the research priorities for the defense virtual reality project was presented. It is expected that this study can be used as a reference material for prioritizing the commercialization of education and training systems in the defense sector.

Effect of Evaluation before Site Application of Poly-acrylic Resin Leakage Repair Materials (폴리아크릴 레진 누수보수재의 선정평가 후 현장 적용에 따른 효과 분석)

  • Cho, Il-Kyu;An, Ki-Won;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.55-61
    • /
    • 2018
  • This study improved the water repair materials of the polyacrylic system applied to concrete structures by controlling expansion, strengthening water resistance, and improving cohesiveness. The improved polyacrylate repair materials were evaluated against the existing products to verify their performance and level of improvement, and applied on-site to the concrete structures that are leaking the improved water. The verification method measured the presence of water leaks and the moisture content of concrete inside. Moisture levels were measured for two months before and after material installation, and at least 0.8 - 1.7% of humidity was reduced after installing polyacrylic resin, and no leakage was found.