• Title/Summary/Keyword: Evaluation of Daylight

Search Result 76, Processing Time 0.028 seconds

The MPPT Control of Photovoltaic System using the Fuzzy PI Controller (퍼지 PI 제어기를 이용한 태양광 발전시스템의 MPPT 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.9-18
    • /
    • 2014
  • This paper proposes the fuzzy PI controller for maximum power point tracking(MPPT) control of photovoltaic system. The output characteristics of the solar cell are a nonlinear and affected by a temperature, the solar radiation. The MPPT control is a very important technique in order to increase an output and efficiency of the photovoltaic system. The conventional perturbation and observation(PO) and incremental conductance(IC) are the method which finding maximum power point(MPP) by the continued self-excitation vibration, and uses the fixed step size. If the fixed step size is a large, the tracking speed of maximum power point is faster, but the tracking accuracy in the steady state is decreased. On the contrary, when the fixed step size is a small, the tracking accuracy is increased and the tracking speed is slower. Therefore, this paper proposes the MPPT control using the fuzzy PI controller that can be improve a MPPT control performance. The fuzzy PI controller is adjusted a input of PI controller by fuzzy control and compensated a cumulative error of fuzzy control by PI controller. The fuzzy PI MPPT control is compared to conventional PO and IC MPPT method for various temperature and radiation condition. This paper proves the validity of the fuzzy PI controller using these results.

The Subjective Evaluation on the Light Environment of Residents at Classrooms (강의실 빛 환경에 대한 재실자의 주관적 평가)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.7 no.1
    • /
    • pp.105-116
    • /
    • 1996
  • The purpose of this study is to improve the quality of the light environment of classroom. To attain this purpose, this study estimated the physical factor and evaluation of the subjective response of classroon located in south and north in the summer and the winter. The results are as followed. 1. The evaluation of the illumination, uniformity factor, daylight factor as physical factor of light environment is good as classroom, but the classroom in south is better that that in north, the light environment in summer is better than winter. 2. The subjective response to light environment of classroom is positive on both seasons at all calssroom. Comparing summer with winter, I found that the difference of subjective response between both classrooms on summer is attentive. 3. The realtion between subjective response and physical factor of light environment in classroom is attentive on the light sense, content sense, uniformity.

  • PDF

Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method (광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가)

  • Kim, Dong-Su;Yoon, Jong-Ho;Shin, Woo-Chul;Lee, Kwang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

Daylighting Performance Evaluation of Lightshelf Window System by Lightscape (Lightscape를 이용한 광선반 창호시스템의 채광성능평가)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

Evaluation of Lighting Environment about the Characteristics of Shading Device (차양장치 특성에 따른 조명환경 평가)

  • Hong, Seong-Kwan;Lim, Ji-Sun;Jung, Yeon-Hong;Kim, Yu-Sin;Choi, An-Seop;Kwun, Joon-Bum
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.153-156
    • /
    • 2008
  • According to the conversion of building into skyscraper, most buildings have curtain wall structures, so the shading device of building is required. The types of shading systems are a roller shade, venetian bind, and vatical blind and so on. A miler shade is mostly used among the shading systems. An experimental evaluation was verified whether there was an effect of shading materials(Perforated panel, Fabric) in each condition by an experiment with artificial lighting and daylight.

  • PDF

Analysis of the Correlation between Human Sensibility and Physical Property of luminous Sources -Focused on Response according to Character of Color Temperature by luminous Sources- (건축조명광원의 광학적 특성에 따른 인간의 감성반응 분석 -조명광원별 색온도 특성에 따른 반응을 중심으로-)

  • Lee, Jin-Sook;Oh, Do-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this research is to acquire emotional data on luminous source by measuring and evaluating human emotional response to the change of the optical feature of luminous environment Luminous sources used in actual architectural space were selected with the optical feature of luminous soured then to measure and analysis human emotional response on Luminous Source. As a result of that 1) In the result of performance measurement by the item of the clear vision of an optic function the fluorescent lamp of daylight indicated the most excellent Performance. 2) In the item of fatigue and stress, the metal halide lamp and mercury lamp showed the most 3) In $\ulcorner$ suitable in light$\lrcorner$, $\ulcorner$a similar with daylight$\lrcorner$ adjective of the amenity item the fluorescent lamp of daylight which color temperature was high turned up to be high also, in $\ulcorner$brilliant$\lrcorner$, adjective, the metal halide lamp and mercury lamp turned up to be low. 4) In the result of factor analysis, three factors $\ulcorner$activity$\lrcorner$, $\ulcorner$potency$\lrcorner$, $\ulcorner$evaluation$\lrcorner$ were abstracted and $\ulcorner$activity$\lrcorner$ factor has the most influential on evaluating the mood of interior space. 5) For the affection in the mood evaluation by each luminous sources, $\ulcorner$activity$\lrcorner$ factor was the most influential by metal halide lamp and fluorescent lamp of daylight, $\ulcorner$potency$\lrcorner$ factor was most influential by kind of incandescent lamp, $\ulcorner$evaluation$\lrcorner$ factor was most influential by fluorescent lamp of low color temperature.

Evaluation of Lighting Performance of Mixed Type Light-shelf in Residential Space According to Angular Variations (주거공간의 혼합형 광선반 각도 변화에 따른 채광성능 평가)

  • Chae, Woori;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.424-433
    • /
    • 2014
  • The purpose of this study is to evaluate the effectiveness in the lighting performance of mixed type light-shelf, by comparing and analyzing the internal light-shelf, external light-shelf, and mixed-type light-shelf. The performance of light-shelf was evaluated according to the angle of light-shelf at summer solstice, winter solstice, vernal equinox, and autumn equinox. The comparative analysis between the internal light-shelf, external light-shelf, and mixed-type light-shelf was carried out using the performance evaluation and analysis method. The result of performance evaluation is shown as follows. The mixed type light-shelf showed the highest lighting performance all at summer solstice, winter solstice, vernal equinox, and autumn equinox, followed by the external light-shelf and the internal light-shelf in the same order. The mixed type light-shelf was the most favorable for bringing daylight to indoors by adjusting the angle of light-shelf, and it also showed the highest lighting performance in terms of uniformity ratio of illumination which indicates the quality of light.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program (시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가)

  • Jeong, Yeol-Wha;Lee, Seun-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

Evaluation of Oxidation Efficiency of Aromatic Volatile Hydrocarbons using Visible-light-activated One-Dimensional Metal Oxide Doping Semiconductor Nanomaterials prepared by Ultrasonic-assisted Hydrothermal Synthesis (초음파-수열합성 적용 가시광 활성 일차원 금속산화물 도핑 반도체 나노소재를 이용한 방향족 휘발성 탄화수소 제어효율 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Choi, Jeong-Hak;Lee, Joon Yeob
    • Journal of Environmental Science International
    • /
    • v.27 no.11
    • /
    • pp.967-974
    • /
    • 2018
  • In this study, we evaluated the photocatalytic oxidation efficiency of aromatic volatile hydrocarbons by using $WO_3$-doped $TiO_2$ nanotubes (WTNTs) under visible-light irradiation. One-dimensional WTNTs were synthesized by ultrasonic-assisted hydrothermal method and impregnation. XRD analysis revealed successful incorporation of $WO_3$ into $TiO_2$ nanotube (TNT) structures. UV-Vis spectra exhibited that the synthesized WTNT samples can be activated under visible light irradiation. FE-SEM and TEM images showed the one-dimensional structure of the prepared TNTs and WTNTs. The photocatalytic oxidation efficiencies of toluene, ethylbenzene, and o-xylene were higher using WTNT samples than undoped TNT. These results were explained based on the charge separation ability, adsorption capability, and light absorption of the sample photocatalysts. Among the different light sources, light-emitting-diodes (LEDs) are more highly energy-efficient than 8-W daylight used for the photocatalytic oxidation of toluene, ethylbenzene, and o-xylene, though the photocatalytic oxidation efficiency is higher for 8-W daylight.