• Title/Summary/Keyword: Evacuation measure

Search Result 47, Processing Time 0.026 seconds

A Study on the Relationship Analysis Model between Visibility and Evacuation Time by User's Movement in the Lower Floor of General Hospital (종합병원 저층부에서의 이용자 이동에 따른 가시성과 피난 시간의 상관관계 분석 모델에 관한 연구)

  • Jung, Gi Hyun;Kweon, Jihoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.11-21
    • /
    • 2019
  • The purpose of this study was to present an analysis model for finding the correlation between visibility and evacuation time as users move in the outpatient department of the general hospital. The spatial scope of the study was limited to the first floor and second floor which are used for the outpatient department. Traffic density in outpatient departments was surveyed on site. Based on the surveyed traffic density, the evacuation simulation model was established for calculating the escape route and evacuation time for an individual user. The traffic density of the outpatient department as per the evacuation time was also calculated. With using evacuation simulations, the flow of evacuees was calculated through the density of traffic over the time of evacuation. Visibility data were set in the simulation model for users' escape routes. A correlation analysis between the product of evacuation flow measure and visibility measure of the evacuation population and evacuation time was performed. The analysis result showed negative correlation within a specific distance range. This study presented an analysis model showing that the evacuation condition considering spatial visibility in the outpatient department of general hospital visibility was negatively related to the analyzed evacuation time at the design stage.

Evaluation of Evacuation Safety of High School According to Change in the Width of Hallway

  • Seon-Yong Jeong;Hong-Sang Lee;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.60-72
    • /
    • 2023
  • The purpose of this study is to measure the change in evacuation time at high schools according to the change in hallway width using an evacuation simulation program and to analyze the result of such change. In order to measure the evacuation time according to the change in the hallway width according to the 「Rules on the Standards for Evacuation and Fire Protection Structures of Buildings」 and to analyze the change in evacuation time resulted from the increase in the number of occupants, a scenario was constructed by applying the 「performance-oriented design method and standard for firefighting facilities, etc.」. As a result of the experiment, it was found that the evacuation time was the shortest when the width of the hallway was the widest, which was 3m. On the other hand, the evacuation time took the longest at 1.8m, which was the width of the second narrowest hallway. For the safety of high school students who spend a lot of time at school, it is necessary to secure a wide hallway width when building a new school or to provide periodic safety education in the case of an existing school whose hallways are considered narrow.

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구)

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

Sign system design for rapid evacuation in earthquake evacuation situations (지진발생 상황에서 신속한 대피를 돕는 사인시스템 디자인)

  • Yoo, Ga-hee;Oh, Kwang-myung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.107-112
    • /
    • 2019
  • Most of the sign systems involved in evacuation are not useful in seismic situations where people have to evacuate with their heads bowed, given that they are at the top of the wall. Based on the analysis and understanding of seismic evacuation situations, this study proposes a sign system as a measure for rapid seismic evacuation. First, understand the seismic situation based on the video analysis of the earthquake evacuation situation. Second, the need for a sign system to help secure evacuation in earthquake situations was derived. Third, the on-site survey examined the suitability of the Sine system installed in Korea as an escape facility for the earthquake evacuation situation. Based on the video analysis and on-site survey, it was concluded that the installation of escape guidance lamps alone could not induce rapid evacuation in the earthquake situation. In this study, a sign system is proposed to help the use of doors by installing a sign system near an emergency exit light.

Study on Stagnation Factors Analysis and Improvement Methods through an Evacuation Experiment (피난실험을 통한 피난시간 지연요인 분석과 개선방안에 관한 연구)

  • Han, Woon-Hee
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.57-66
    • /
    • 2018
  • The most urgent requirement in the event of disaster and fire in a skyscraper is to establish a system that enables people inside to evacuate safely. Hence, a practical direction needs to give evacuees confidence in the evacuation by reducing the psychological anxiety caused by the relatively large number of people inside and at the same time, the physically prolonged evacuation travel line. Evacuation tests with large numbers of people were conducted three times to solve these challenges and identify phenomena and issues that occurred during the experiment. The results revealed the factors that could cause a delay in evacuation and suggested improvements. The study results of this paper are as follows. First, a recent fire at a multipurpose high-rise resulted in a number of casualties due to a lack of experience with the disaster prevention system. To prevent such cases from occurring in advance, adaptability was achieved by conducting evacuation tests. Second, the data collected in the evacuation simulation statistics and the actual escape drills were compared and analyzed. Third, in the evacuation experiment, a large number of people could not participate in the experiment. The reasons for not participating were analyzed and their impact on the actual evacuation time was confirmed. Fourth, equipment aids were purchased to establish the optimal response measure to the causes of a delay in escape time and the standards for ensuring the safety of the evacuee were specified by developing improvements to minimize the evacuation delay time through comparative before and after analysis of the experiment. These results can be used for fire safety control of skyscrapers to improve the efficiency of evacuation.

A Study on the Evaluation of Evacuation Safety Function of an Elderly Care Hospital (일개 노인요양병원의 피난안전성능 평가에 관한 연구)

  • Kim, Jong-Bum;Kim, Ja-Ok;Back, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.9-19
    • /
    • 2010
  • Recently, Korea is constantly increasing its elderly care hospitals, and requires establishment of general evacuation plan considering old people's behavioral characteristics and physical states in emergency situations such as fire, and etc. In addition, because most of the facility users are patients under serious dementia and stroke, they feel difficulty evacuating by themselves, with differing evacuation time according to each walking status (bed, wheel chair, and various supplementary instruments), which is why it makes it difficult to have them all evacuate. This paper, in order to suggest data reference for designing on the basis of functionality, used various collected data utilizing Simulex to measure evacuation time through the model of elderly care hospital, a medical facility. During the study, several problems were found.

Development of the Personal Disaster Evacuation Apparatus in Case of the Life Damage by the landslide (I) - Focusing on the Load Weight and Material Test - (산사태로 인한 인명피해 대비 개인용 재난대피기구 개발 (I) - 재하하중 및 재료시험 중심으로 -)

  • Kim, Jung Meyon;Hwang, Dea Won;Park, Sung Yong;Lim, Chang Su;Yeon, Kyu Seok;Kim, Yong Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.39-47
    • /
    • 2016
  • The houses are formed in the lower part of the mountain slope face in most agricultural areas of Korea, and old residents accounting for a large portion of the agricultural populations cannot respond to the evacuation quickly when the landslide happens, and the possibility the life damage occurs is high. Therefore, it is urgent to arrange the measure on this. This study is intended to develop the personal disaster evacuation apparatus that can be installed in the house to minimize the life damage by the landslide and to develop the self-initiative evacuation apparatus. This study suggested the load applicable to the personal disaster evacuation apparatus by quantitatively analyzing the effect of the load of rockslides and avalanches caused by the landslide on the structure. Also, the material property of materials was calculated through the tension and bending intensity test after making the specimen of glass fiber reinforced plastic (GFRP) member. The load weight and material property drawn from this study can be used as the basic material for the stability analysis of the personal disaster evacuation apparatus.