DOI QR코드

DOI QR Code

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik (Department of Architectural Engineering, The University of Dongguk)
  • 발행 : 2018.12.01

초록

Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

키워드

HKCGBT_2018_v7n4_409_f0001.png 이미지

Fig. 1. Status of Each Entrance of the subject Example Building.

HKCGBT_2018_v7n4_409_f0002.png 이미지

Fig. 2. Left (C1), Right (C2) Placement of the Measuring Equipment.

HKCGBT_2018_v7n4_409_f0003.png 이미지

Fig. 3. Field Measurement Range of Example Building.

HKCGBT_2018_v7n4_409_f0004.png 이미지

Fig. 4. C1's Entrance.

HKCGBT_2018_v7n4_409_f0005.png 이미지

Fig. 5. C2's Entrance and Walkway Flow.

HKCGBT_2018_v7n4_409_f0006.png 이미지

Fig. 6. Analysis of C2's Walkway Flow.

HKCGBT_2018_v7n4_409_f0007.png 이미지

Fig. 7. Setting of the Detailed Investigation Interval of C1.

HKCGBT_2018_v7n4_409_f0008.png 이미지

Fig. 8. Setting of the Detailed Investigation Interval of C2.

HKCGBT_2018_v7n4_409_f0009.png 이미지

Fig. 9. Left (C1), Right (C2) Measuring Distance.

HKCGBT_2018_v7n4_409_f0010.png 이미지

Fig. 10. Analysis of Walking Patterns C1.

HKCGBT_2018_v7n4_409_f0011.png 이미지

Fig. 11. Analysis of Walking Patterns C2.

참고문헌

  1. Hwang, E. K. and Youn, H. J. (2011) A Basic Survey for the Guideline of the Office Occupant Load. J. Korean Soc. Hazard Mitig., Vol. 11, No. 6, pp. 45-51. https://doi.org/10.9798/KOSHAM.2011.11.6.045
  2. Kiyono, J. and Mori, N. (2004) Simulation of Emergency Evacuation Behavior During a Disaster by Use of Ellptic Distinct Elements. 13th World Conference on Earthquake Engineering, Paper No. 134, Vancouver, B.C., Canada.
  3. Kachroo, P., Al-nasur, S. J., Wadoo, S. A., and Shende, A. (2008) Pedestrian Dynamics: Feedback Control of Crowd Evacuation. Springer-Veralg, Germany.
  4. Kim, H. Y., Yoo, Y. H., and Rie, D. H. (2017) A Study on the Operation Plan of Evacuation Shelter to Improve Evacuation Performance of Existing Underground Subway Station. J. Korean Soc. Hazard Mitig., Vol. 17, No. 4, pp. 159-164.
  5. Ma, Y., Lee, E. W. M., and Yuen, R. K. K. (2017) Dual Effects of Pedestrian Density on Emergency Evacuation. Physics Letters A, Vol. 381, No. 5, pp. 435-439. https://doi.org/10.1016/j.physleta.2016.11.043
  6. Nam, H. W., Kwak, S. Y., and Jun, C. M. (2016) A Study on Comparison of Improved Floor Field Model and Other Evacuation Models. Journal of the Korea Society for Simulation, Vol. 25, No. 3, pp. 41-51. https://doi.org/10.9709/JKSS.2016.25.3.041
  7. Park, S. J., Lee, J. S., Kang, D. S., Jung, E. H., Jun, H. J., and Park, S. B. (2007) A Study on Walking Speed and Stride Length According to Age. Proceedings of Eromonomics Society of Korea 2007 Conference, p. 432.
  8. Son, Y. N., Yoon, S. H., and Yee, J. J. (2009) Basic Study on Analyzing Evacuation Experiment Using Video Analysis Processing. Proceedings of Annual Conference of the Architectural Institute of Korea Planning & Design, Vol. 29, No. 1, pp. 637-640.
  9. Wang, J. H., LI, N., and Zhang, L. (2015) Small Group Behaviors and Their Impacts on Pedestrian Evacuation. 2015 27th Chinese Control and Decision Conference (CCDC), IEEE.
  10. Youn, H. J., Hwang, E. K., and Kim, J. H. (2012) Measurements of Flow-Rate with Korean for Performance Based Egress Safety Design. J. Korean Soc. Hazard Mitig., Vol. 12, No. 2, p. 139. https://doi.org/10.9798/KOSHAM.2012.12.2.139