• 제목/요약/키워드: Evacuation measure

검색결과 47건 처리시간 0.019초

종합병원 저층부에서의 이용자 이동에 따른 가시성과 피난 시간의 상관관계 분석 모델에 관한 연구 (A Study on the Relationship Analysis Model between Visibility and Evacuation Time by User's Movement in the Lower Floor of General Hospital)

  • 정기현;권지훈
    • 대한건축학회연합논문집
    • /
    • 제21권3호
    • /
    • pp.11-21
    • /
    • 2019
  • The purpose of this study was to present an analysis model for finding the correlation between visibility and evacuation time as users move in the outpatient department of the general hospital. The spatial scope of the study was limited to the first floor and second floor which are used for the outpatient department. Traffic density in outpatient departments was surveyed on site. Based on the surveyed traffic density, the evacuation simulation model was established for calculating the escape route and evacuation time for an individual user. The traffic density of the outpatient department as per the evacuation time was also calculated. With using evacuation simulations, the flow of evacuees was calculated through the density of traffic over the time of evacuation. Visibility data were set in the simulation model for users' escape routes. A correlation analysis between the product of evacuation flow measure and visibility measure of the evacuation population and evacuation time was performed. The analysis result showed negative correlation within a specific distance range. This study presented an analysis model showing that the evacuation condition considering spatial visibility in the outpatient department of general hospital visibility was negatively related to the analyzed evacuation time at the design stage.

Evaluation of Evacuation Safety of High School According to Change in the Width of Hallway

  • Seon-Yong Jeong;Hong-Sang Lee;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권2호
    • /
    • pp.60-72
    • /
    • 2023
  • The purpose of this study is to measure the change in evacuation time at high schools according to the change in hallway width using an evacuation simulation program and to analyze the result of such change. In order to measure the evacuation time according to the change in the hallway width according to the 「Rules on the Standards for Evacuation and Fire Protection Structures of Buildings」 and to analyze the change in evacuation time resulted from the increase in the number of occupants, a scenario was constructed by applying the 「performance-oriented design method and standard for firefighting facilities, etc.」. As a result of the experiment, it was found that the evacuation time was the shortest when the width of the hallway was the widest, which was 3m. On the other hand, the evacuation time took the longest at 1.8m, which was the width of the second narrowest hallway. For the safety of high school students who spend a lot of time at school, it is necessary to secure a wide hallway width when building a new school or to provide periodic safety education in the case of an existing school whose hallways are considered narrow.

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권2호
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

대규모 위락시설의 피난안전성능 평가에 관한 연구 (A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities)

  • 박봉래;공하성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.165-173
    • /
    • 2009
  • 성능위주의 설계가 법제화 되면서 화재 및 피난에 대한 연구가 활발히 진행 중이다. 성능위주설계는 인명의 안전성을 증대 시키는 방향으로 발전되어야 한다. 또한, 성능위주의 설계는 소방분야뿐만 아니라 건축법령에서 정하고 있는 피난에 관한 규정을 포함하여 검토되어야 한다. 본 논문은 성능위주의 설계 시 참고가 될 자료로 제시하기위해 다중이용시설인 광주광역시의 OO나이트클럽을 하나의 모델로 삼아 피난시간을 예측하였다. 이를 위해 우리나라와 외국의 피난에 관련된 규정과 연구논문들을 검토하고, 현장을 방문하여 자료를 수집하였다. 그리고 수집된 자료들을 피난프로그램인 Simulex의 입력 자료로 사용하여 피난시간을 측정하였다. 이 연구의 검토과정 및 결과에서 몇 가지 문제시되는 사항을 발견할 수 있었다.

Implementation of Occupant Density and Walking Pattern Measurement for Emergency Evacuation and Safety in High-Rise Multi-Purpose Facilities

  • Lee, Myung Sik
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.409-415
    • /
    • 2018
  • Recently, many countries around the world began to show interest in safety against terrorism, fire, and natural disasters. This study aimed to propose a quantitative measurement system for emergency evacuation and safety for various kinds of terrorism and fire within high-rise multi-purpose facilities, which can measure the pedestrians' ordinary walking patterns in the concourse with the highest pedestrian volume out of all the spaces within multi-story buildings, predict pedestrians' evacuation walking lines when a sudden disaster breaks out, and analyze the gait coefficient, occupant density, and evacuation behavior time.

화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구 (The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications)

  • 구인혁;김혜원;진승현;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

지진발생 상황에서 신속한 대피를 돕는 사인시스템 디자인 (Sign system design for rapid evacuation in earthquake evacuation situations)

  • 유가희;오광명
    • 문화기술의 융합
    • /
    • 제5권3호
    • /
    • pp.107-112
    • /
    • 2019
  • 피난과 관련된 대부분의 사인시스템은 벽의 상단부에 있다는 점에서 고개를 숙인 채 대피해야 하는 지진 상황에서 유용하지 않다. 본 연구는 지진 대피 상황의 분석과 이해를 바탕으로 신속한 지진 대피를 위한 대책으로서 사인 시스템을 제안하고자 한다. 첫째, 지진 대피 상황의 동영상 분석을 바탕으로 지진 상황을 이해한다. 둘째, 지진 상황에서 안전한 대피를 돕는 사인 시스템이 가져야 할 필요요건을 도출하였다. 셋째, 현장조사를 통해 국내에 설치되어 있는 사인시스템이 지진대피 상황을 위한 피난설비로서 적절한 기능을 갖추었는지 적합성을 고찰하였다. 동영상 분석 및 현장 조사를 바탕으로 피난유도등의 설치만으로는 지진 상황에서 신속한 대피를 유도할 수 없다는 결론을 도출하였다. 본 연구에서는 피난유도등 근처에 사인시스템을 설치하여 문의 사용성을 돕는 사인시스템을 제안한다.

피난실험을 통한 피난시간 지연요인 분석과 개선방안에 관한 연구 (Study on Stagnation Factors Analysis and Improvement Methods through an Evacuation Experiment)

  • 한운희
    • 한국화재소방학회논문지
    • /
    • 제32권2호
    • /
    • pp.57-66
    • /
    • 2018
  • 초고층건축물에서 재난 및 화재발생 시 가장 절실히 요구되는 것은 재실자가 안전하게 피난할 수 있는 체계를 구축하는 것이라 하겠다. 이는 물리적으로 피난 동선이 길어졌고, 동시에 상대적으로 많아진 재실자로 인해 피난자들이 느끼는 심리적 불안감을 해소시켜 피난에 대한 자신감을 심어줄 수 있는 구체적 방안이 필요하기 때문이다. 본 연구에서는 이러한 과제를 해결하기 위해서 3회에 걸쳐 대규모 인원이 참여한 피난실험을 하였으며, 실험 중 나타난 현상과 문제점을 파악하고, 피난시간에 지연을 초래할 수 있는 요인을 발굴하고 이의 개선 방안을 제안하였다. 이 논문의 연구 결과를 요약하면 다음과 같다. 첫째, 최근 발생한 초고층주상복합건축물 화재에서 방재시스템 운영미숙으로 많은 인명피해가 발생하였다. 이와 같은 사태를 사전에 예방하기 위하여 피난실험을 실시하여 적응력을 확보하였다. 둘째, 피난시뮬레이션 통계와 피난실험에서 수집된 Data 수치를 비교 분석 검증하였다. 셋째, 피난실험 과정에서 실험에 참여가 불가한 다수의 인원들이 있었으며, 이러한 참여 불가사유를 분석하고, 그 내용이 실제 피난시간에 어떠한 영향을 미치는지를 검증하였다. 넷째, 피난시간 지연 초래 요인에 대한 최적의 대응 방안을 수립하기 위하여 피난장비를 구입하고, 실험 전후 비교분석을 통하여 피난시간 지연을 최소화하기 위한 개선점을 도출, 피난자의 안전을 확보하는데 필요한 기준을 구체화하였다. 마지막으로 이 연구결과를 초고층건축물 소방안전관리에 활용될 수 있도록 하여 피난의 효율성을 확보할 수 있도록 하였다.

일개 노인요양병원의 피난안전성능 평가에 관한 연구 (A Study on the Evaluation of Evacuation Safety Function of an Elderly Care Hospital)

  • 김종범;김자옥;백은선
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.9-19
    • /
    • 2010
  • 최근 우리나라는 노인요양병원이 꾸준히 증가하고 있으며 화재등과 같은 비상 상황에서 노인의 행동 특성과 신체 상태를 고려한 종합적인 피난계획의 수립이 요구된다. 또한 시설 이용자의 대부분이 중증의 치매 및 뇌졸중을 앓고 있는 환자이기 때문에 자력으로 피난이 곤란하고 환자의 보행상태(침대, 휠체어, 각종 보조기구) 등에 따라 피난시간이 상이하여 이용자 전원을 피난시키는 것이 어렵기 때문이다. 본 논문은 성능위주의 설계 시 참고가 될 자료를 제시하기 위해 의료시설인 노인요양병원을 모델로 여러 수집된 자료들로 Simulex를 이용하여 피난시간을 측정하였다. 이 연구의 과정에서 몇 가지 문제시 되는 사항을 발견할 수 있었다.

산사태로 인한 인명피해 대비 개인용 재난대피기구 개발 (I) - 재하하중 및 재료시험 중심으로 - (Development of the Personal Disaster Evacuation Apparatus in Case of the Life Damage by the landslide (I) - Focusing on the Load Weight and Material Test -)

  • 김정면;황대원;박성용;임창수;연규석;김용성
    • 한국농공학회논문집
    • /
    • 제58권5호
    • /
    • pp.39-47
    • /
    • 2016
  • The houses are formed in the lower part of the mountain slope face in most agricultural areas of Korea, and old residents accounting for a large portion of the agricultural populations cannot respond to the evacuation quickly when the landslide happens, and the possibility the life damage occurs is high. Therefore, it is urgent to arrange the measure on this. This study is intended to develop the personal disaster evacuation apparatus that can be installed in the house to minimize the life damage by the landslide and to develop the self-initiative evacuation apparatus. This study suggested the load applicable to the personal disaster evacuation apparatus by quantitatively analyzing the effect of the load of rockslides and avalanches caused by the landslide on the structure. Also, the material property of materials was calculated through the tension and bending intensity test after making the specimen of glass fiber reinforced plastic (GFRP) member. The load weight and material property drawn from this study can be used as the basic material for the stability analysis of the personal disaster evacuation apparatus.