• Title/Summary/Keyword: Evacuation Characteristics

Search Result 209, Processing Time 0.026 seconds

Characteristics of Sediment Movement and Local Peoples' Countermeasure for Evacuation - focused on Inie areas of Kangwon-do - (집중 호우에 따른 부유토사 유출 특징 및 주민 대응 -2006넌 7월 강도 인제 지역을 중심으로-)

  • Kang, Sang-Hyeok
    • Spatial Information Research
    • /
    • v.16 no.1
    • /
    • pp.11-17
    • /
    • 2008
  • In order to reduce flood damage with debris flow, it is necessary to build up comprehensive flood control, including structural and non-structural countermeasures. In this paper, the decision making factors of individual refuge activities which are major non-structural activities to save peoples, lives against flood have been estimated based on questionnaire survey. Furthermore, in order to effective debris flow countermeasures, its simulation has carried out and it will useful fur minimizing their damages.

  • PDF

Application of Space Syntax Theory to the Design of Emergency Lightings (공간구문론을 이용한 비상조명 설계 방법론 검토)

  • Won, Seul-Ki;Choi, An-Seop;Kim, Young-Uk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.189-194
    • /
    • 2006
  • The emergency lighting plan for underground space should be done with consideration of characteristics of the space. Through the Space Syntax theory, it is possible to do quantitative analysis of the space. Integration and intelligibility are major index of this theory and we can use them as emergency lighting design parameters. For this study, human behaviors and survivor's evacuation routes in fire emergencies are analyzed through literature review. Based on those results, this study suggests the methodology of emergency lighting plan in underground space.

  • PDF

Acute Subdural Hematoma Associated with Ruptured Intracranial Aneurysm: Diagnosis and Emergent Aneurysm Clipping

  • Kim, Jung-Min;Hur, Jin-Woo;Lee, Jong-Won;Kim, Myoung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.375-379
    • /
    • 2005
  • Rarely, rupture of a cerebral aneurysm causes an acute subdural hematoma(SDH) in addition to subarachnoid hemorrhage(SAH). We report clinical and radiological characteristics of five cases, as well as potential pitfalls in the diagnosis and the treatment of this life-threatening condition. The patients ranged in age from 42 to 76 years. The Hunt-Hess grade on admission was grade III in one patient, grade IV in two, and grade V in two. All five patients un-derwent one-stage operation (both SDH evacuation and clipping of the aneurysm). The outcome was good recovery in two patients, persistent vegetative state in two, and death in one. Patients with a good outcome had a better Hunt-Hess grade on admission, with less amount of SDH.

A Study on the Improvement of the Resident' Evacuation Management Standard In Rapid Slope Areas Reflecting Rainfall Characteristics (강우특성을 반영한 급경사지 주민대피관리 기준 개선에 관한 연구)

  • Park, Ki Bum;Kim, Kyo Sik;Yang, Jun Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.257-257
    • /
    • 2021
  • 2007년 급경사지 재해 예방에 관한 법률 제정 이후, 급경사지에 대한 여러 가지 대책과 연구가 진행되고 있으나 2020년 발생한 최장기간의 장마에 안전한 것으로 판단되는 A-C등급의 급경사지 붕괴에 의해 많은 피해가 발생하였다. 특히 2020년에는 A-C등급의 급경사지 붕괴건수가 185건이나 발생하여 급경사지 평가기준에 대한 개선의 요구가 증가하고 있다. 본 연구에서는 현행 급경사지 주변 지역의 주민대피 관리기준의 강우특성이 과거 2009년에서 2014년 피해자료를 기반으로 산정된 강우기준이 적용되고 있다. 그러나 최근 기후변화에 따른 초과 강수량과 분석강우의 신뢰성을 확보할 필요가 있다. 따라서 본 연구에서는 최근 발생된 강우특성이 반영되지 못한 현행 급경사지 주민대피 관리기준의 강우기준에 대한 개선을 위해 강우자료의 30년 이상의 강우분석을 반영하고 최근의 기후변화 특성에 따른 강우분석자료를 검토하여 주민대피 관리기준에서의 강우기준 개선에 대한 연구를 하였다.

  • PDF

A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System (소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

Wear Characteristics of CBN Tools on Hard Turning of AISI 4140 (고경도강(AISI 4140, HrC60)의 하드터닝에서 가공속도 및 윤활조건 변경에 따른 CBN 공구의 마모 특성)

  • Yang, Gi-Dong;Park, Kyung-Hee;Lee, Myung-Gyu;Lee, Dong Yoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.799-804
    • /
    • 2014
  • Hard turning is a machining process for hardened materials with high surface quality so that grinding process can be eliminated. Therefore, the hard turning is capable of reducing machining time and improving productivity. In this study, hardened AISI4140 (high-carbon chromium steel) that has excellent yield strength, toughness and wear resistance was finish turned using CBN tools. Wear characteristics of CBN tool was analyzed in dry and MQL mixed with nano-particle (Nano-MQL). The dominant fracture mechanism of CBN tool is diffusion and dissolution wear on the rake surface resulting in thinner cutting edge. Abrasive wear by hard inclusion in AISI4140 was dominant on the flank surface. Nano-MQL reduced tool wear comparing with the dry machining but chip evacuation should be considered. A cryogenically treated tool showed promising result in tool wear.

A Study on the Lifetime Characteristics of AC-PDP as a Parameter of MgO Preparation (MgO 증착 변수에 따른 AC-PDP의 수명 특성 연구)

  • Choi, M.S.;Kim, Y.R.;Choi, Y.C.;Park, C.S.;Kim, D.H.;Lee, H.J.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1631-1635
    • /
    • 2002
  • In order to be good display, the ac PDP lifetime should be guaranteed over 30000 hours. Therefore, to satisfy these demands, it is need to find out main factors in ac PDP affecting the lifetime. In this paper, the characteristics of lifetime as a parameter of the MgO deposition rate conditions is investigated. MgO protective layers is fabricated by E-beam. Before measuring the lifetime we have carefully peformed high temperature evacuation and aging procedure, which is essential for providing the initial condition of our experiment. If MgO deposition rate increased, MgO film becomes dense and an adhesive power of MgO film gets better and because occurrence rate of the MgO cluster decreases, lifetime of MgO will be improved. As a result, ac PDP lifetime can be improved due to the improvement of MgO by MgO preparation conditions.

  • PDF

Investigation on Characteristics of Various Mold Packing Materials in Lost Foam Casting of Aluminum Alloy (알루미늄 합금 소실모형주조 시의 주형충전재에 따른 특성변화)

  • Kim, Ki-Young;Lee, Kyung-Whoan;Rim, Kyung-Hwa
    • Journal of Korea Foundry Society
    • /
    • v.22 no.3
    • /
    • pp.137-143
    • /
    • 2002
  • Silica sand, zircon sand, and steel shots were used as mold packing materials in lost foam casting of the aluminum alloy bar. Vibration acceleration in three directions and temperatures in the casting and mold were measured, and packing and cooling characteristics of these materials were investigated. Packing densities increased with increase in vibration magnitude and time, and were $1.41{\sim}1.49g/cm^2$ for silica sand, $2.54{\sim}2.86g/cm^2$ for zircon sand, and $3.92{\sim}4.52g/cm^2$ for steel shots. Sound castings were obtained only without evacuation of the flask during pouring. Solidification time became faster in order of silica sand, zircon sand and steel shot packing because steel shot has the highest cooling capacity of them. Solidification time of steel shot packing was shortened to about 1/2 of silica sand packing. Cooling capacity of sand mold was generally evaluated by heat diffusivity of the mold, however could be simply evaluated with specific heat per unit volume of the packing material in lost foam casting.

A Study on Warnning Criteria Investigation of Automated Rainfall Warning System -Focused on Realationship of Water Level, Discharge and Precipitation - (자동우량경보시설 경보발령기준 검토 연구 - 수위, 유출량, 강수량의 관계를 중심으로 -)

  • Ahn, Jae-Chan;Lee, Jong-Seol;Chol, Woo-Chung;Lee, Byong-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.101-109
    • /
    • 2008
  • Automated rainfall warning system is a facility to prevent casualties who were recreating in the down stream region with operating lead broadcasting or signaling warning automatically when torrential rainfall occurs in mountainous area. But standard of conventional warning does not consider the characteristics of basin, and warning signal. Evacuation signal 1 and evacuation signal 2 are uniformly signaled when the 10minute moving total of observed rainfall is higher than 4 mm, 6 mm, and 8 mm respectively. therefore, local governments and relative agencies had re-established the standard of warning by analyzing the risk water level, critical discharge and reference rainfall, which are considering the characteristics of basin. In this study the standard of conventional and re-established warning of weolseong basin, which is available to acquire a real rainfall. There are analyzed by considering the risk water level, critcal discharge and reference rainfall. Also this study compares rainfall of conventional and re-established warning standard and indentifies problems by analyzing adequacy of rainfall estimation for warning and proposes alternative. The standard of conventional warning which investigates with the converted rainfall(unit of a minute) issued too many alarm. The re-established standard upward has the necessity which will be regulated about the alarm announcement number of times. Considers the safety, upward regulation of alarm standard rainfall is a necessity which will be prudent.