• Title/Summary/Keyword: Ethylene Oxide

Search Result 478, Processing Time 0.029 seconds

The Responses of Yukbo Strawberry (Fragaria ananassa Duch.) Fruit to Nitric Oxide

  • Eum, Hyang-Lan;Lee, Seung-Koo
    • Food Science and Biotechnology
    • /
    • v.16 no.1
    • /
    • pp.123-126
    • /
    • 2007
  • The quality of Yukbo strawberry (Fragaria ananassa Duch.) fruit declines rapidly after harvest. Therefore, we examined the effects of nitric oxide (NO) on its respiration rate, quality, and shelf life. Strawberries were fumigated for 5 hr at 0, 50, 100, 200, or $500\;{\mu}L/L$ NO atmosphers, followed by a hold at $18^{\circ}C$ in air. Treatment with NO delayed the onset of ethylene production ad reduced respiration, which at $18^{\circ}C$ resulted I a maintained quality and prolonged shelf life. The NO-treated strawberries were also firmer and had a lower incidence of disease than the untreated fruit. The effect of NO on fruit quality was dose-dependent. Strawberries that were treated with low and high concentrations of 50 and $500\;{\mu}L/L$ No, respectively, had severe disease incidence and were of poor quality. Treating with NO at a concentration of $200\;{\mu}L/L$ appeared to slow down the ripening and senescence of fruit stored at $18^{\circ}C$. Calyx browning, respiration, and rot development progressed more quickly in strawberries treated with $500\;{\mu}L/L$ NO compared to those treated with $200\;{\mu}L/L$ No.

Polarity-tuned Gel Polymer Electrolyte Coating of High-voltage LiCoO2 Cathode Materials

  • Park, Jang-Hoon;Cho, Ju-Hyun;Kim, Jong-Su;Shim, Eun-Gi;Lee, Yun-Sung;Lee, Sang-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.2
    • /
    • pp.117-124
    • /
    • 2011
  • We demonstrate a new surface modification of high-voltage lithium cobalt oxide ($LiCoO_2$) cathode active materials for lithium-ion batteries. This approach is based on exploitation of a polarity-tuned gel polymer electrolyte (GPE) coating. Herein, two contrast polymers having different polarity are chosen: polyimide (PI) synthesized from thermally curing 4-component (pyromellitic dianhydride/biphenyl dianhydride/phenylenediamine/oxydianiline) polyamic acid (as a polar GPE) and ethylene-vinyl acetate copolymer (EVA) containing 12 wt% vinyl acetate repeating unit (as a less polar GPE). The strong affinity of polyamic acid for $LiCoO_2$ allows the resulting PI coating layer to present a highly-continuous surface film of nanometer thickness. On the other hand, the less polar EVA coating layer is poorly deposited onto the $LiCoO_2$, resulting in a locally agglomerated morphology with relatively high thickness. Based on the characterization of GPE coating layers, their structural difference on the electrochemical performance and thermal stability of high-voltage (herein, 4.4 V) $LiCoO_2$ is thoroughly investigated. In comparison to the EVA coating layer, the PI coating layer is effective in preventing the direct exposure of $LiCoO_2$ to liquid electrolyte, which thus plays a viable role in improving the high-voltage cell performance and mitigating the interfacial exothermic reaction between the charged $LiCoO_2$ and liquid electrolytes.

Study on the Characteristics of Carcinogenic Pollutant Emissions and Cancer Incidence Rates in Korea (국내 발암물질 배출량 특성과 암발생 추이에 관한 연구)

  • Im, JiYoung;Kim, Bokyeong;Kim, Hyunji;Yun, Jeonghyeon;Heo, HwaJin;Lee, JiHo;Lee, SangMok;Lee, ChungSoo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.2
    • /
    • pp.160-168
    • /
    • 2018
  • Objectives: The purposes of the study were to investigate hazardous pollutant emissions changes among group 1 carcinogens. The emissions characteristics were compared with national cancer registration statistics. Methods: A survey of group 1 carcinogen hazardous pollutant emissions (trichloroethylene, benzene, vinyl chloride, formaldehyde, 1,3-butadiene, ethylene oxide, chromium and its compounds, 3,3'-dichloro-4,4-diaminodiphenylmethane, chloromethyl methyl ether, arsenic and its compounds, cadmium and its compounds, o-toluidine) was conducted through a homepage for 2001-2015. The emission of hazardous chemicals and the cancer trend analysis for 2001-2015 were performed using the Korean statistical information service through its homepage as a reference. Results: Emissions of more than 95% of the substances listed as group 1 carcinogens over the last five years were made up of trichloroethylene, benzene, vinyl chloride, formaldehyde, 1,3-butadiene, and ethylene oxide. As a result of the comparison of emission results and cancer incidence rates, carcinogen pollutant emissions showed a tendency to decrease continuously. In addition, the incidence of cancer tended to increase, but showed a tendency to decrease from 2012. Conclusion: The results indicate hazardous pollutant emissions have continued to increase. However, no association between emissions and health effects was shown and more research is needed.

Novel Polyurethane Binder for Propellant based on Hydroxyl-terminated Copolyether (폴리에테르 공중합체 디올(HTPE)을 사용한 새로운 추진제용 폴리우레탄 바인더)

  • Song Jong-Kwon;Pan Xiao;Lee Bum-Jae;Jeon Jun-Pyo;Hwang Gab-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.417-421
    • /
    • 2005
  • Novel two synthetic technics using cationic ring-opening copolymerization of tetrahydrofuran (THF) and ethylene oxide (EO), or just polymerized EO on Poly-THF, could lead to random hydroxyl-terminated poly(EO-ran-THF) or tri-block PEG-PTHF-PEC, respectively. These reactions were carried out using $BF_3O(C_2H_5)_2$ as catalyst, 1,4-butanediol or PTHF as diol initiator. Copolymer structures were controlled by monomer feed ratio, or initial PTHF and EO monomer added amount. The molecular weight of polymer was merely dependant on the ratio of [monomer]/[diol], but not on catalyst. Well-defined random and block hydroxyl-terminated copolyether was found to be as the prepolymer for the propellant binder from the experiment to polyurethane with them.

  • PDF

Fabrication and Characterization of Polyurethane Foam for Wound Dressing (창상치료용 폴리우레탄 폼의 제조 및 특성연구)

  • Kim, Won-Il;Kim, Cheol-Joo;Kim, Dae-Yeon;Kwon, Oh-Kyoung;Kwon, Oh-Hyeong
    • Polymer(Korea)
    • /
    • v.34 no.5
    • /
    • pp.442-449
    • /
    • 2010
  • Polyurethane(PU) prepolymer was synthesized from ethylene oxide/propylene oxide(EO/PO) random polyether polyol, toluene diisocyanate and chain extender such as ethylene glycol and 1,4-butanediol. PU foams having various compositions were fabricated from PU prepolymers with different hard segment contents(%) and mixed foaming solution of different compositions. PU foam from chain extender-introduced PU prepolymer and mixed foaming solution containing glycerin showed better mechanical property than other groups. Various PU foams were tested on their mechanical property, moisture vapor transmission rate, absorption speed, absorptivity, morphology and cell culture test. According to the test, the PU foam fabricated from chain extender-introduced PU prepolymer and mixed foaming solution containing optimum composition of F-68, glycerin and CMC was found to have the best property for wound dressing materials. From in vivo animal study, it was confirmed that above PU foam showed rapid wound recovery.

Small-Angle Neutron Scattering Study of the Structure of Micelles Formed by a Polystyrene-Poly(ethylene oxide) Diblock Copolymer in Aqueous Solution (수용액 내 폴리스티렌-폴리에틸옥사이드 이중블록공중합체 미셀 구조에 대한 소각중성자산란 연구)

  • Kang, Byoung-Yook;Choi, Mi-Ju;Hwang, Kyu-Hee;Lee, Kwang-Hee;Jin, Byoung-Suk
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.485-489
    • /
    • 2009
  • The temperature dependence of the structure of micelles formed by a deuterated polystyrene-poly(ethylene oxide) diblock copolymer (dPS-PEO) in heavy water were investigated with small-angle neutron scattering (SANS). SANS data were analyzed using the hard-sphere structure factor in combination with the form factor of a core-shell model. The micelle aggregation number and corona radius were obtained from the fits to the SANS data. The micelle aggregation numbers varied with temperature from 229 at $25^{\circ}C$ to 240 at $45^{\circ}C$, with a corresponding increase in the core radius. However, the shell thickness of micelles decreased with increasing temperature from 6.2 to 5.8 nm. These structural changes of micelles might be ascribed to the decrease in the hydration volume per hydrophilic group in the corona because of the increase in hydrophobicity of the PEO block with increasing temperature.

Topical Delivery of Budesonide Emulsion Particles in the Presence of PEO-PCL-PEO Triblock Copolymers

  • Cho, Jin-Hun;Baek, Hyon-Ho;Lee, Jung-Min;Kim, Jung-Hyun;Kim, Dae-Duk;Cho, Heui-Kyoung;Cheong, In-Woo
    • Macromolecular Research
    • /
    • v.17 no.12
    • /
    • pp.969-975
    • /
    • 2009
  • This article describes the topical delivery and localization of budesonide through the hairless mouse skin. Two poly(ethylene oxide)-block-poly($\varepsilon$-caprolactone)-block-poly(ethylene oxide) (PEO-PCL-PEO) triblock copolymers (T 222 and T 252) having different CL:EO ratios were added in the preparation of budesonide particles stabilized with poly(vinyl alcohol) (PVA) and Tween 80 under ultrasonication. For comparison, a commercial PEO-PPO-PEO triblock copolymer (F68) was studied under the same condition. To demonstrate the effects of the triblock copolymer, the particle size of budesonide emulsion, entrapment efficiency, and in vitro release were measured and compared. The budesonide particles stabilized by the triblock copolymers had a diameter of ca. 350 nm with entrapment efficiencies of 66-76%. The In vitro release profiles of all samples showed an initial burst followed by sustained release. The skin penetration and permeation of budesonide were analyzed by using a Frantz diffusion cell. T 222 and T 252 exhibited higher total permeation amounts, but lower budesonide penetration amounts, than F68. The results suggest that the partitioning of budesonide in each skin layer can be adjusted in order to avoid skin thinning and negative immune response arising from the penetration of budesonide in blood vessels.

Enhanced characteristics of TCO films with $(SiO_2)_3(ZnO)_7$ gas barrier layer on various plastic substrates (다양한 플라스틱 기판위에 $(SiO_2)_3(ZnO)_7$ 보호층을 갖는 투명 전도성 박막들의 특성 향상)

  • Kwon, Oh-Jeong;Kim, Dong-Yung;Ryu, Sung-Won;Sohn, Sun-Young;Hong, Woo-Pyo;Kim, Hwa-Min;Hong, Jae-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.283-284
    • /
    • 2008
  • Electrical and optical characteristics of indium tin oxide (ITO) and indium zinc oxide (IZO) films without and with $(SiO_2)_3(ZnO)_7$ at.% (SZO) film deposited on poly(ethylene naphthalate) (PEN) and poly(ethylene terephthalate (PET) substrates as a gas barrier layer for flexible display were studied. The ITO and IZO films with SZO gas barrier layer showed the improved properties which were both the high transmittance of average 80% in the visible light range and the decreased sheet resistance as compared to those of ITO and IZO films without SZO layer. Particularly, the PEN substrate with only SZO gas barrier layer had a low water vapor transmission rate (WVTR) of $\sim10^{-3}g/m^2$/day. Thus, we suggest that the SZO film with protection ability against the water vapor permeation can be applied to gas barrier layer for flexible display.

  • PDF

Separation of Bacteria Using Capillary Electrophoresis (모세관 전기영동을 이용한 박테리아의 분리)

  • Moon, Byoung-Geoun;Choi, Kyu-Seong;Lee, Sang-Chun;Kim, Yong-Seong
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.2
    • /
    • pp.144-150
    • /
    • 2004
  • Various experimental factors that affect the separation of bacteria were investigated using capillary electrophoresis. At different buffer concentrations, gram-positive bacteria and gram-negative bacteria showed somewhat different migration behavior under high electric filed. The separation efficiency was also investigated as a function of concentration of bacterium injected into the capillary. In order to separate bacteria as the difference of size and shape, water soluble polymers such as poly(ethylene)oxide (PEO), polyvinylpyirrolidone (PVP), and dextran were studied. PEO, which is more flexible and has lower steric hinderance, showed the best separation efficiency. The mixed bacteria sample of Micrococcus lysodeikticus as gram-positive bacteria and Aerobacter aerogenes as gram-negative bacteria were successfully analyzed with PEO.

Electrotransport of Donepezil Hydrochloride from Poly(ethylene oxide) Hydrogel (폴리에틸렌옥사이드 하이드로겔을 이용한 도네페질염산염의 이온토포레시스 피부투과)

  • Choi, Yu-Ri;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.91-100
    • /
    • 2010
  • The objective of this work is to study transdermal delivery of donepezil hydrochloride (DH) using iontophoresis and to evaluate various factors which affect the transdermal transport. After the flux study using 4 kinds of hydrogel, hydrogel containing 8% poly(ethylene oxide) (PEO) was chosen as the hydrogel for further studies. Under experimental condition, DH was stable. We have studied the effect of polarity, current density, drug concentration and current profile on transdermal flux and compared the results. In vitro flux study was performed at $33^{\circ}C$, using side-by-side diffusion cell and full thickness hairless mouse skin. DH is positively charged at pH 7.4, and anodal delivery was much larger than cathodal and passive delivery at all current densities studied (0.2, 0.4 and 0.6 mA/$cm^2$). Cathodal delivery showed higher flux than passive flux. Flux increased as the concentration of DH in hydrogel increased. Pulsatile application of current showed smaller flux value than the application of continuous current. Based on these results, we have evaluated the possibility of delivering enough amount of DH to reach the therapeutic level. The maximum cumulative amount of DH transported for 12 hours was 455 ${\mu}g/cm^2{\cdot}hr$ when the amount of DH in the hydrogel was 3 mg/mL and the current density was 0.4 mA/$cm^2$. If the patch size is 10 $cm^2$, then we can deliver 4.6 mg for 12 hours. Because the daily dosage of DH is 5 mg, it seems possible to deliver clinically effective amount of DH using iontophoresis. This study also provides some information about the role of electrorepulsion and electroosmosis during the transport through skin.