• Title/Summary/Keyword: Estimation of doses

Search Result 79, Processing Time 0.021 seconds

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

The Big Vitamin D Mistake

  • Papadimitriou, Dimitrios T.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.4
    • /
    • pp.278-281
    • /
    • 2017
  • Since 2006, type 1 diabetes in Finland has plateaued and then decreased after the authorities' decision to fortify dietary milk products with cholecalciferol. The role of vitamin D in innate and adaptive immunity is critical. A statistical error in the estimation of the recommended dietary allowance (RDA) for vitamin D was recently discovered; in a correct analysis of the data used by the Institute of Medicine, it was found that 8895 IU/d was needed for 97.5% of individuals to achieve values ${\geq}50nmol/L$. Another study confirmed that 6201 IU/d was needed to achieve 75 nmol/L and 9122 IU/d was needed to reach 100 nmol/L. The largest meta-analysis ever conducted of studies published between 1966 and 2013 showed that 25-hydroxyvitamin D levels <75 nmol/L may be too low for safety and associated with higher all-cause mortality, demolishing the previously presumed U-shape curve of mortality associated with vitamin D levels. Since all-disease mortality is reduced to 1.0 with serum vitamin D levels ${\geq}100nmol/L$, we call public health authorities to consider designating as the RDA at least three-fourths of the levels proposed by the Endocrine Society Expert Committee as safe upper tolerable daily intake doses. This could lead to a recommendation of 1000 IU for children <1 year on enriched formula and 1500 IU for breastfed children older than 6 months, 3000 IU for children >1 year of age, and around 8000 IU for young adults and thereafter. Actions are urgently needed to protect the global population from vitamin D deficiency.

Effect of Particulate Matter on the UV-Disinfection of Virus and Risk Assessment (입자성 물질 농도가 바이러스의 UV-처리와 위해성에 미치는 영향 평가)

  • Shin, Yu-Ri;Yoon, Chun-Gyeong;Rhee, Han-Pil;Lee, Seung-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1028-1033
    • /
    • 2010
  • Wastewater reuse for agricultural irrigation needs treatment and control of pathogens to minimize risks to human health and the environment. In order to evaluate the water quality of UV-treated reclaimed water, this study focused on the relationship between micro-pathogens and particulate matters. MS2 was selected as an index organism because it has similar characteristics to human enteric virus and strong resistance to UV disinfection. The turbidity and suspended solid (SS) were selected for test parameters. In this study, it was performed with different UV doses (30 and $60mJ/cm^2$) for estimation of the MS2 inactivation rate using collimated beam batch experiments in the laboratory. The experiment results by turbidity or SS concentration presented that the increased concentration of them lowered MS2 inactivation. At the turbidity (below 4.27 NTU) and SS (below 1.47 mg/L) of the low level range, the inactivation of 60 UV dose is higher than 30 UV dose. However, at the turbidity and SS of the high level, the increasing UV dose did not show apparent increasing the MS2 inactivation. In quantitative microbial risk assessment (QMRA), it can confirm the trend that $P_D$ and turbidity concentrations have positive correlationship at the low concentration, which was also observed in SS. The QMRA can be helpful in communication with public for safe wastewater reuse and be recommended.

Review of Guidelines for Radon and Estimation of Radiation dose (라돈의 가이드라인 고찰 및 선량 예측)

  • Chung, Eun Kyo;Kim, Kab Bae;Jang, Jae Kil;Song, Se Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.109-118
    • /
    • 2016
  • Objectives: To review reference levels by the international and domestic management and provide the basis for setting occupational exposure limits(OELs) of radon in Korea Methods: Government's organizations with laws and systems for monitoring radon exposure were investigated and compared. There are five laws governing Indoor Air Quality(IAQ) control such as Occupational Safety and Health Act, Indoor Air Quality Control in Public Use Facilities, Etc. Act, School Health Act, Public Health Control Act and Parking Lot Act in Korea. It was surveyed that a total of 32 countries including 24 countries in the European Union(EU), six countries in Asian and two countries in North America setting the reference levels for radon in the world. Results: In Korea, there are set guidelines for radon in the Ministry of Environment and the Ministry of Education. Reference levels of radon for existing dwellings were $150{\sim}400Bq/m^3$ for Western European countries, and $200{\sim}1,500Bq/m^3$ in Eastern European countries. Approximately 67% of those EU countries were set up $400Bq/m^3$ to the standards for existing dwellings. EU countries such as Luxembourg, Finland, Norway, Sweden and Russia had adopted mandatory level for radon. Radon guidelines for new dwellings were set more strictly reference level($200Bq/m^3$) than existing dwellings. Conclusions: International organizations such as ICRP, UNSCEAR and NCRP, etc. had recommended the guidelines for radon. It was calculated the relation of the dose conversion factors with the annual effective doses. the OELs of radon suggest to need to establish $150Bq/m^3$ for office room and $400{\sim}1,000Bq/m^3$ for the workplace.

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.

Protective Effect of Panax ginseng extract on Renal Functions Altered by Mercuric Chloride in Albino Rats

  • Saxena, Prabhu-N.;Mahour, K.;Kumar, Ashok
    • Journal of Ginseng Research
    • /
    • v.30 no.3
    • /
    • pp.100-105
    • /
    • 2006
  • Liver and kidney are specific organs which play an active role in biotransformation and detoxification mechanisms. Ant adverse effect of chemicals or heavy metal can cause the delay or fade in these mechanisms. Present study was designed to find out the protective effect of Panax ginseng extract on renal functions altered by mercuric chloride (heavy metal) in albino rat. Fifty albino rats were divided into 10 groups. Five groups for acute study and five groups for sud-acute study viz. control group (Tween 20 and distilled water), mercuric chloride treated group (0.926 mg/kg body wt. for acute and 0.044 mg/kg body wt. for sub-acute group after calculated $LD_{50}$ (9.26 mg/kg body wt.) by probit analysis (Finney, 1971), Panax ginseng extract treated group (10 mg/kg body wt. for acute and sub-acute sets), mercuric chloride treated followed by Panax ginseng extract and Panax ginseng extract followed by mercuric chloride group. All doses were given orally by gavage tube. The result revealed that the serum urea and creatinine significantly increased in mercuric chloride treated group, while significantly decreased (p<0.01) in Panax ginseng extract group after acute and sub-acute treatment. The biochemical estimation is also confirmed by nephropathological aspect. However, the Panax ginseng extract treated followed by mercuric chloride group is more prominent than the mercuric chloride treated followed by Panax ginseng extract group. It can be concluded that Panax ginseng extract had a protective nature on renal functions against mercuric chloride toxicity in albino rats.

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.

Cytogenetic and Medical Examination Report of Accidental Exposure of Nuclear Power Plant Worker using Multiple Assays (원자력 발전소 피폭자 건강영향평가 사례보고)

  • Lee, Jung-Eun;Yang, Kwang-Hee;Jang, Yun-Kun;Jeong, Mee-Seon;Kim, Chong-Soon;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.111-115
    • /
    • 2007
  • A deuterium oxide leakage accident occurred on October 4, 1999, at nuclear power plant in Korea. The concentration of tritium in air increased and 22 workers were exposed by tritium at that time. It is well known that tritium causes internal exposure. Therefore, we examined complete blood cell count, physical and biological dosimetry fur 13 workers among whole 22 workers to check the health effect and to evaluate the dose estimation of tritium exposure. The leukocyte count test, one of general blood test, was normal. The estimated doses were 0 - 4.44 mSv by physical dosimetry and 0-37 mGy by biological dosimetry. This dose does not exceed radiation dose limit, and the clinical symptoms of the exposed workers were not shown. The consistency between clinical sign and estimated dose means that physical and biological dosimetry were very useful especially in accident evaluation.

Neutron Generation from a 24 MV Medical Linac (24 MV 의료용 선형가속기의 중성자 발생에 관한 연구)

  • Jeong Dong Hyeok;Kang Jeong Ku;Lee Jeong Ok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • The energy spectra and dose calculations were performed for secondary neutrons from a 24 MV LINAC using MCNPX code (V2, 4, 0). The energy spectra for neutrons and photons emitted from the LINAC head, and absorbed dose to water were calculated in water phantom. The absorbed doses calculated with Monte Carlo were $0.66\~0.35$ mGy/photon Gy at the surface to d=5 cm, and calculated with interaction data was 0.52 mGy/photon Gy at the depth of electron equilibrium in water. We have shown that this work can be applied to dose estimation of neutrons from high energy LINAC through the comparison of our results with other results.

  • PDF