Performance Analysis of Adaptive Extended Kalman Filter in Tracking Radar (추적 레이더에서 적응형 확장 칼만 필터의 성능 분석)

  • Song, Seungeon;Shin, Han-Seop;Kim, Dae-Oh;Ko, Seokjun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.4
    • /
    • pp.223-229
    • /
    • 2017
  • An angle error is a factor obstructing to track accurate position in tracking radars. And the noise incurring the angle error can be divided as follows; thermal noise and glint. In general, Extended Kalman filter used in tracking radars is designed with considering thermal noise only. The Extended Klaman filter uses a fixed measurement error covariance when updating an estimate state by using ahead state and measurement. But, a noise power varies according to the range. Therefore we purposes the adaptive Kalman filter which changes the measurement noise covariance according to the range. In this paper, we compare the performance of the Extended Kalman filter and the proposed adaptive Kalman filter by considering KSLV-I (Korean Satellite Launch Vehicles).

Analysis of Phase Error Due to the Azimuth Angle of the Wave Plates in the Shearography Using Wollaston Prism (Wollaston prism을 이용한 스펙클패턴 전단간섭법에 있어서 파장판의 방위각에 의한 위상오차 해석)

  • Kim, Soo-Gil;Kim, Ki-Soo;Ko, Myung-Sook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.1-7
    • /
    • 2005
  • We introduced the method to obtain four speckle patterns with relative phase shift of ${\pi}/2$ by the polarizing elements, and calculate the phase at each point of the speckle pattern in shearography using Wollaston prism and polarizing elements. Ant we analyzed the phase error caused by the azimuth angles of wave plates used in the proposed method by Jones matrix.

Development of Computer Aided System for Error Assessoment for Multi-axis Machine Tools using the Double Ball Bar (기구볼바를 이용한 공작기계의 오차평가 시스템 개발)

  • 문준희;박희재;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.336-342
    • /
    • 1994
  • This paper presents an useful technique for assessing the volumetric error in multi_axis machine tools using the kinematic double ball bar and 3 dimensional spherical contouring. The developed system proposes the 3 dimensional spherical contour for the error analysis. The developed system input the measured radial data, analysing the volumetric errors such as positional, strightness, angle, and squareness errors, etc. The developed system has been tested in a practical machine tool, and showed high

  • PDF

A Study on the Transmission Error of a Star type Epicyclic Gear Train (스타형 유성기어열의 전달오차에 관한 연구)

  • 류형태;이동환;천길정
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.206-212
    • /
    • 1999
  • In this paper, the transmission error of a atar type Epicyclic Gear Train (EGT) has been studied. Dynamic analysis has been executes calculate the rotation angle of the input and output shafts at various loads. Transmission Error of EGT has been measured to compare with the analysis results. There are qualitative similarity between the experimental and analytical results.

  • PDF

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

Imperfection Parameter Observer and Drift Compensation Controller Design of Hemispherical Resonator Gyros

  • Pi, Jaehwan;Bang, Hyochoong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.4
    • /
    • pp.379-386
    • /
    • 2013
  • The hemispherical resonator gyroscope is a type of vibratory gyroscope, which can measure angle or angular rate, based on its operating mode. This paper deals with the case when the hemispherical resonator gyroscope is operated in angle measurement mode. In angle measurement mode, the resonator pattern angle precesses, with respect to the external rotation input, by the principle of the Coriolis effect, so that the external rotation can be estimated, by measuring the amount of precession angle. However, this pattern angle drifts, due to the manufacturing error of the resonator. Since the drift effect causes degradation of the angle estimation performance of the resonator, the corresponding drift compensation control should be performed, to enhance the estimation performance. In this paper, a mathematical model of the hemispherical resonator gyro is first introduced. By using the mathematical model, a nonlinear observer for imperfection parameter estimation, and the corresponding compensation controller are designed to operate hemispherical resonator gyros, as angle measurement sensors.

Angle Servo Method for Holographic Data Storage System using Angle Multiplexing (각 다중화 홀로그래픽 정보 저장장치를 위한 각 보상 기법)

  • Kim, Nak-Yeong;Kim, Jang-Hyun;Lim, Sung-Yong;Han, Cho-Lok;Lee, Jae-Seong;Yang, Hyun-Seok;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • A control method for the angle servo of reference beam during reading recoded data images of a holographic data storage system is presented. The recording scheme with angle offset is adopted in order to verify the proposed angle servo. Using this recording scheme, the angle error signal is generated and we can implement the angle servo. Experiments have been performed on recording and reading data images to compensate Bragg angle mismatch.

Development of a Contact Angle Measurement Method Based Upon Geometry (기하학적 원리에 의거한 접촉각의 측정)

  • 김동수;표나영;서승희;최우진;권영식
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.41-45
    • /
    • 1998
  • A Hew way of contact angle measurement is derived based on simple geometrical calculation. Without using complicated contact angle measurement instrument. Just measuring the diameter and height of liquid lens made it possible to calculate the contact angle value with a reasonable reliability. To validate the contact angle value obtained by this method, contact angle of the same liquid lens is measured using conventional goniometer and it is verified that two values are nearly same within the limit of observational error.

  • PDF

Vibration Mode Shape Changed by Phase Angle in Vibration Testing Using Phase-Shifting ESPI (위상이동 ESPI를 이용한 진동실험에서 위상각에 따른 진동모드 형상의 변화)

  • 정현철;김경석;양승필;장호섭;박찬주;조영학;김종수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.443-446
    • /
    • 2003
  • The vibration mode shape changed by the phase angle that can be controlled by phase-shifting ESPI system is discussed. For the phase-shifting ESPI experiment the stroboscopic illumination by using AOM(Acousto-Optic Modulator) is needed, and the initial phase angle can be adjusted by the program. The vibration mode shape is changed when the initial phase angle is changed. We examined the vibration mode shape change due to the initial phase angle change at each resonance frequency. Through this study, we found that in the vibration testing using phase-shilling ESPI the vibration mode shape is improved in the quality by adjusting exact phase angle and the error of the quantitative vibration analysis can be reduced.

  • PDF

Development of Horizontal Attitude Monitoring System for Agricultural Robots (농업 로봇 용 수평 자세 모니터링 시스템 개발)

  • Kim, Sung Deuk;Kim, Cheong Worl;Kwon, Ik Hyun;Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.87-91
    • /
    • 2019
  • In this paper, we have development of horizontal attitude monitoring system for agricultural robots. A two-axis gyro sensor and a two-axis accelerometer sensor are used to measure the horizontal attitude angle. The roll angle and pitch angle were measured through the fusion of the gyro sensor signal and the acceleration sensor signal for the horizontal attitude monitoring of the robot. This attitude monitoring system includes GPS and Bluetooth communication module for remote monitoring. The roll angle and pitch angle can be measured by the error of less than 1 degree and the linearity and the reproducibility of the output signal are excellent.