• Title/Summary/Keyword: Equivalent thickness

Search Result 605, Processing Time 0.18 seconds

Performance Evaluation of Floor Vibration of Biaxial Hollow Slab Subjected to Walking Load (보행하중에 대한 2방향 중공슬래브의 진동성능 평가)

  • Kim, Min-Gyun;Park, Hyun-Jae;Lee, Dong-Guen;Hwang, Hyun-Sik;Kim, Hyun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.11-21
    • /
    • 2009
  • Considering that the weight of a biaxial hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a biaxial hollow slab is not significantly lower than that of a general solid slab, there has been a growing need for biaxial hollow slab systems, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a biaxial hollow slab system are quite different from the conventional floor systems. Therefore, in this study, the floor vibration of a biaxial hollow slab system subjected to walking load is investigated in comparison with a conventional floor slab system. For the efficiency of time history analysis, an equivalent plate slab model that can precisely represent the dynamic behavior of a biaxial hollow slab system is used. From the analytical results, it was determined that vibration of a biaxial hollow slab system subjected to walking load is evaluated as "office-level vibration," according to the classifications of the architectural institute of Japan and ANSI.

Electrical and Chemical Properties of ultra thin RT-MOCVD Deposited Ti-doped $Ta_2O_5$

  • Lee, S. J.;H. F. Luan;A. Mao;T. S. Jeon;Lee, C. h.;Y. Senzaki;D. Roberts;D. L. Kwong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.202-208
    • /
    • 2001
  • In Recent results suggested that doping $Ta_2O_5$ with a small amount of $TiO_2$ using standard ceramic processing techniques can increase the dielectric constant of $Ta_2O_5$ significantly. In this paper, this concept is studied using RTCVD (Rapid Thermal Chemical Vapor Deposition). Ti-doped $Ta_2O_5$ films are deposited using $TaC_{12}H_{30}O_5N$, $C_8H_{24}N_4Ti$, and $O_2$ on both Si and $NH_3$-nitrided Si substrates. An $NH_3$-based interface layer at the Si surface is used to prevent interfacial oxidation during the CVD process and post deposition annealing is performed in $H_2/O_2$ ambient to improve film quality and reduce leakage current. A sputtered TiN layer is used as a diffusion barrier between the Al gate electrode and the $TaTi_xO_y$ dielectric. XPS analyses confirm the formation of a ($Ta_2O_5)_{1-x}(TiO_2)_x$ composite oxide. A high quality $TaTi_xO_y$ gate stack with EOT (Equivalent Oxide Thickness) of $7{\AA}$ and leakage current $Jg=O.5A/textrm{cm}^2$ @ Vg=-1.0V has been achieved. We have also succeeded in forming a $TaTi_x/O_y$ composite oxide by rapid thermal oxidation of the as-deposited CVD TaTi films. The electrical properties and Jg-EOT characteristics of these composite oxides are remarkably similar to that of RTCVD $Ta_2O_5, suggesting that the dielectric constant of $Ta_2O_5$ is not affected by the addition of $TiO_2$.

  • PDF

Investigation charge trapping properties of an amorphous In-Ga-Zn-O thin-film transistor with high-k dielectrics using atomic layer deposition

  • Kim, Seung-Tae;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.264-264
    • /
    • 2016
  • 최근에 charge trap flash (CTF) 기술은 절연막에 전하를 트랩과 디트랩 시킬 때 인접한 셀 간의 간섭현상을 최소화하여 오동작을 줄일 수 있으며 낸드 플래시 메모리 소자에 적용되고 있다. 낸드 플래시 메모리는 고집적화, 대용량화와 비휘발성 등의 장점으로 인해 핸드폰, USB, MP3와 컴퓨터 등에 이용되고 있다. 기존의 실리콘 기반의 플래시 메모리 소자는 좁은 밴드갭으로 인해 투명하지 않고 고온에서의 공정이 요구되는 문제점이 있다. 따라서, 이러한 문제점을 개선하기 위해 실리콘의 대체 물질로 산화물 반도체 기반의 플래시 메모리 소자들이 연구되고 있다. 산화물 반도체 기반의 플래시 메모리 소자는 넓은 밴드갭으로 인한 투명성을 가지고 있으며 저온에서 공정이 가능하여 투명하고 유연한 기판에 적용이 가능하다. 다양한 산화물 반도체 중에서 비정질 In-Ga-Zn-O (a-IGZO)는 비정질임에도 불구하고 우수한 전기적인 특성과 화학적 안정성을 갖기 때문에 많은 관심을 받고 있다. 플래시 메모리의 고집적화가 요구되면서 절연막에 high-k 물질을 atomic layer deposition (ALD) 방법으로 적용하고 있다. ALD 방법을 이용하면 우수한 계면 흡착력과 균일도를 가지는 박막을 정확한 두께로 형성할 수 있는 장점이 있다. 또한, high-k 물질을 절연막에 적용하면 높은 유전율로 인해 equivalent oxide thickness (EOT)를 줄일 수 있다. 특히, HfOx와 AlOx가 각각 trap layer와 blocking layer로 적용되면 program/erase 동작 속도를 증가시킬 수 있으며 넓은 밴드갭으로 인해 전하손실을 크게 줄일 수 있다. 따라서 본 연구에서는 ALD 방법으로 AlOx와 HfOx를 게이트 절연막으로 적용한 a-IGZO 기반의 thin-film transistor (TFT) 플래시 메모리 소자를 제작하여 메모리 특성을 평가하였다. 제작 방법으로는, p-Si 기판 위에 열성장을 통한 100 nm 두께의 SiO2를 형성한 뒤, 채널 형성을 위해 RF sputter를 이용하여 70 nm 두께의 a-IGZO를 증착하였다. 이후에 소스와 드레인 전극에는 150 nm 두께의 In-Sn-O (ITO)를 RF sputter를 이용하여 증착하였고, ALD 방법을 이용하여 tunnel layer에 AlOx 5 nm, trap layer에 HfOx 20 nm, blocking layer에 AlOx 30 nm를 증착하였다. 최종적으로, 상부 게이트 전극을 형성하기 위해 electron beam evaporator를 이용하여 platinum (Pt) 150 nm를 증착하였고, 계면 결함을 최소화하기 위해 퍼니스에서 질소 가스 분위기, $400^{\circ}C$, 30 분의 조건으로 열처리를 했다. 측정 결과, 103 번의 program/erase를 반복한 endurance와 104 초 동안의 retention 측정으로부터 큰 열화 없이 메모리 특성이 유지되는 것을 확인하였다. 결과적으로, high-k 물질과 산화물 반도체는 고성능과 고집적화가 요구되는 향후 플래시 메모리의 핵심적인 물질이 될 것으로 기대된다.

  • PDF

A Study on the Insulation Performance of Composite Multilayer Insulation by Applciation of Heat Storage Tank (축열조용 복합 다층 단열재의 단열 성능 연구)

  • Choi, Gyuhong;Hwang, Seung Sik;Shin, Donghoon;Park, Woo Sung;Park, Dae Woong;Son, Seung Kil;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.82-87
    • /
    • 2014
  • MLI(Multi-layer Insulation) is widely used to get highly insulating on cryogenic system in order to reduce heat loads. MLI for satellites thermal performance is changed by materials and laminated method. In this study, a composite multilayer insulation by application of heat stroage tank performance were compared with materials and laminated to change the way. Experimental methods of the KS C 9805 was used, the composite multilayer insulation and EPS was compared with the insulation performance. A method for analysis of experimental results is the equivalent thickness about CMI and the insulation performance were used to compare thermal conductance. As a results, the equivalnet thickenss and the thermal conductance of the composite multilayer insulation were smaller than the EPS and the thermal performance are more excellent. In addition, the configuration of the composite multilayer insulation materials and laminated method varies depending on the overall heat transfer coefficient was confirmed.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

Diagnosis of Spinal Arachnoid Cyst using Magnetic Resonance Imaging in a Dog (개에서 자기공명영상을 이용한 척추부 지주막 낭종의 진단)

  • Shin, Chang-ho;Kim, Young-ki;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.464-468
    • /
    • 2015
  • A 6-year-old, intact male maltese was presented with hindlimb ataxia of 4 day duration. Physical and neurological examinations revealed a bright, alert, and responsive dog, with no evidence of cranial nerve deficits, conscious proprioceptive deficits. Spinal reflexes of the hind and forelimbs were normal. Patellar, cranial tibial, and withdrawal reflexes were normal. Pain could not be elicited on manipulation of the neck or palpation of the spinal column. Survey radiographs of the vertebral column were unremarkable. Computed tomography (CT) scans in the transverse plane were performed. The results of CT imaging were unremarkable. Magnetic resonance imaging (MRI) in both sagittal and transverse planes was performed. The extent of the lesion was 25 mm in length by 4 mm in thickness. The spinal cord was deviated ventrally and appreared thinner. On T1-weighted and FLAIR images, a discrete hypointense lesion dorsal to the spinal cord was observed at L1-2 which was contiguous with the subarachnoid space. On T2-weighted images, this region was hyperintense, consistent with a fluid-filled structure. The signal intensity of the cysts was equivalent to cerebrospinal fluid (CSF). Surgical treatment involving dorsal laminectomy had successful outcomes.

Effect of HA Crystals Precipitated by Hydrothermal-Treatment on the Bioactivity of Ti-6Al-7Nb Alloy (열수처리에 의해 석출된 HA 결정이 Ti-6Al-7Nb 합금의 생체활성에 미치는 영향)

  • Kwon O. S.;Choi S. K.;Moon J. W.;Lee M. H.;Bae T. S.;Lee O. Y.
    • Korean Journal of Materials Research
    • /
    • v.14 no.9
    • /
    • pp.607-613
    • /
    • 2004
  • This study was to investigate the surface properties of electrochemically oxidized Ti-6Al-7Nb alloy by anodic spark discharge technique. Anodizing was performed at current density 30 $mA/cm^2$ up to 300 V in electrolyte solutions containing $DL-{\alpha}$-glycerophosphate disodium salt hydrate($DL-{\alpha}$-GP) and calcium acetate (CA). Hydrothermal treatment was done at $300^{\circ}C$ for 2 hrs to produce a thin outermost layer of hydroxyapatite (HA). The bioactivity was evaluated from HA formation on the surfaces in a Hanks' solution with pH 7.4 at $36.5^{\circ}C$ for 30 days. The size of micropores and the thickness of oxide film increased and complicated multilayer by increasing the spark forming voltage. Needle-like HA crystals were observed on anodic oxide film after the hydrothermal treatment at $300^{\circ}C$ for 2 hrs. When increasing $DL-{\alpha}$-GP in electrolyte composition, the precipitated HA crystals showed the shape of thick and shorter rod. However, when increasing CA, the more fine needle shape HA crystals were appeared. The bioactivity in Hanks' solution was accelerated when the oxide films composed with strong anatase peak with presence of rutile peak. The increase of amount of Ca and P was observed in groups having bioactivity in Hanks' solution. The Ca/P ratio of the precipitated HA layer was equivalent to that of HA crystal and it was closer to 1.67 as increasing the immersion time in Hanks' solution.

Studies on the Nutritional Status and Energy Balance of Korean Women Divers (한국 해녀의 영양섭취 상태 및 에너지 균형에 관한 연구)

  • Joo, Soon-Jae;Lee, Ki-Yull;Lee, Yang-Cha;Park, Yang-Saeng
    • Journal of Nutrition and Health
    • /
    • v.16 no.4
    • /
    • pp.233-242
    • /
    • 1983
  • This study was attempted to investigate Korean women divers' nutritional status and the effect of their putting on rubber diving suits on the energy balance. For these investigations, measurements of nutrients intake, energy intake and energy consumption during diving work were performed. This study was conducted in summer and winter of 1981. Nutrition survey was carried out by interviewing each individual and the energy consumption during diving work was calculated from the extra oxygen consumption over the resting value and the change in mean body temperature in sea water. The results obtained were summarized as follows : 1) In summer, the divers' dietary intake were 2,454 Kcal for energy, 69g of protein, 16g of fat 578mg of calcium, 11mg of iron, 526 Retinol Equivalent of vitamin A, 1.1mg of thiamin, 1.3mg of riboflavin, 19mg of niacin and 50mg of ascorbic acid. These results showed that the intakes of energy, thiamin, riboflavin, niacin and ascorbic acid were higher than the Korean Recommended Dietary Allowances (RDA). Whereas in winter, the nutrients intake except iron, riboflavin, and vitamin A were higher than the RDA. 2) The energy consumption, measured by oxygen consumption and changes in body heat content, used in diving work were 260 Kcal per day in summer and 370 Kcal per day in winter. These values were about 600-700 Kcal per day lower than 1960s' 1,000 Kcal per day. The divers' energy intake were 2,454 Kcal per day in summer and 2,487 Kcal per day in winter. These data were about 550 Kcal per day lower than 1960s' intake. Since divers have worn the rubber diving suits, the energy consumption decreased as compared with the energy consumed while wearing cotton suits. And this seemed to be resulted in decreasing the energy intake. This result also showed that the balance between energy expenditure and energy intake were kept. 3) The mean subcutaneous fat thickness of divers and nondivers were 8.85 and 9.03 mm respectively. These values were as high as four times as those of 1960s'. The total body fat contents wers 25.8 percent in both diver and nondiver groups and showed an increase as high as twice as compared with 1960s' values.

  • PDF

RADIOGRAPHIC INTERPRETATION OF EXPERIMENTALLY PRODUCED BONY DEFECT ACCORDING TO kVp (관전압 변화에 다른 실험적 골결손부의 방사선사진상의 판독)

  • Nam Hye Kyung;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.265-276
    • /
    • 1990
  • The purpose of this experiment was to evaluate radiographic interpretation, of various sized 60 periapical and 60 cancellous lesions in 10 mandibular sections of 5 dogs according to kVp (65, 70, 75, 80 and 85 kVp). The results were as follows; The change of kilovoltage within 65kVp-85kVp range did not have influence on the radiographic interpretation of the same-sized bony defects at the constant radiographic density (p> 0.05). When the bony defects were less than the size of No.2 round bur, radiographic interpretation of bony defects prepared with No.2 round bur was easier than those prepared with No. 1 round bur at 80-85kVp in periapical region (p<0.05). However, in cancellous bone, this radiographic interpretation was easier at 65-75kVp (p<0.05). There were significant differences in the radiographic interpretation between the defects confined only to the cancellous, bone and the defects involved in the compact bone (p<0.05). However there were no significant differences between the defects confined only to the cancellous bone and the defects involved in junctional area of cancellous and compact bone (p>0.05). From the results of densitometric analysis, there was a difference in densitometric measurements at the same radiographic interpretation scores, and aluminum equivalent differences of 0.15-1.66㎜ thickness were needed for radiographic interpretation.

  • PDF

Practical Modeling for the Vibration Analysis of a Composite Deck Slab Structures (합성데크 바닥판 구조물의 진동해석을 위한 실용적인 모형화)

  • Kim, Jae-Yeol;Kim, Gee-Cheol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.43-50
    • /
    • 2005
  • Composite slab structures consisted with steel deck plate and concrete material show generally anisotropic structural behavior because of different stillness between the major direction and sub-direction of deck plate, and also the structures can be regarded as the laminated slab structures. It is necessary for the composite deck slab structures to carry out the exact vibration analysis to evaluate the serviceability. Also, it is needed to evaluate the exact structural behavior of composite deck slab with a layered orthotropic materials. In this paper, the thickness of lopping concrete and deck plate are used to calculate the material coefficient stiffness of a sub-direction, and an equivalent depth calculated from sectional stiffness of concrete and deck plate is applied to get the silliness of a major direction. The stiffness of two layered composite plates with different depth is determined by laminated theory. It is concluded that the presented method car efficiently analyze the structural behavior of composite deck slab consisted with steel deck plate and concrete material in the practical engineering field.