• 제목/요약/키워드: Equivalent Winding

검색결과 137건 처리시간 0.025초

65kW급 HEV용 SRM의 설계 (Design of 65kW Class SRM for HEV)

  • 김태형;안진우;안영주;문재원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.562-564
    • /
    • 2005
  • This paper presents the reasonable design parameters of a SRM for hybrid electric vehicle driving. For the design of SRM, the initial model is designed using the equivalent magnetic circuit method. In order to optimize the SRM for HEV. The initial model is redesigned by FEM with the variation of the stock length and turns of winding. This paper shows that a flat-topped current of a phase can be made from a change of the stack length and the number of turns for high efficiency, high average torque and a lower torque ripple. The change of current falling time as a variation of turn-off angle was shown by FEA. The iron loss and copper loss were described. The torque of the redesigned motor is suitable for low and high speed ranges to drive a HEV that was verified by the speed-torque curve.

  • PDF

철손을 고려한 자기저항 동기전동기의 정수 측정 및 동특성 예측 (Parameter Measurement and Dynamic Performance Estimation of Synchronous Reluctance Motor Considering Iron Loss)

  • 이정섭;홍정표;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.58-60
    • /
    • 1999
  • This paper presents dynamic performance prediction using Matlab / simulink after parameter estimation of synchronous reluctance motor considering iron loss. Test motor is 3 phase SynRM with the segmental rotor, rating power is 0.175KW. Experiment equipment is consists of testing motor, dynamometer, vector invertor dynamocontroller, and power analyser. The stator iron loss and rotor iron loss are modelled by additional windings on three-phase winding axis. These windings are transformed into d-q axis, and are represented as equivalent eddy current windings. P-Q circle diagram method and single phase standstill method are used to measure motor parameters considering iron loss.

  • PDF

가스터빈 구동 공냉식 100 MW 발전기의 개념설계 (Conceptual Design of 100 MW Turbogenerator)

  • 박도영;황돈하;하경덕;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.88-90
    • /
    • 1998
  • The conceptual design of turbine-driven air-cooled 100 MW generator is presented. The generators rating is 100 MW 3-phase 2pole 13.8 kV 0.85 pf 60 Hz. The conceptual design is described by the process of designing the stator, rotor, and obtaining some of equivalent circuit parameters. The design process starts from the output coefficient G, and utilizes the classical design equations with parameters used in the modern designs. The slot dimensions of the stator and rotor are obtained with their respective winding dimensions.

  • PDF

IGBT 인버터 구동 저압 유도전동기 고정자 권선의 과도전압 해석 (Analysis of Voltage Distribution in the Stator Winding of Low-Voltage Induction Motor driven by IGBT PWM Inverter)

  • 김창화;이용한;안호진;황돈하;박도영;허익구;최병원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.690-692
    • /
    • 2000
  • In this paper voltage distribution in the windings of an inverter fed induction motor is studied. High frequency parameters of the induction motor are calculated using finite element analysis. With these parameters. a high frequency equivalent circuit of the inverter-cable-motor is formed. The transient analysis is performed using ATP-EMTP package to estimate the voltage distribution in the motor windings.

  • PDF

고온초전도동기모터의 시변자계에 따른 회전자의 손실 해석에 관한 연구 (A Study on the Analysis for Electrical Losses of the Rotor considering Time Varying Field of High Tc Superconducting Synchronous Motor)

  • 송명곤;윤용수;장원갑;장인배;이상진;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.340-342
    • /
    • 1998
  • This paper presents the ac losses simulation in the rotor having an high-Tc superconducting field winding using Ag sheathed Bi-2223. The analysis was conducted with an equivalent model of the high-Tc superconducting motor under transition condition during the load that varies from 250watt to 500watt. The simulation results show that the transient state lasts for about 2 seconds, and the ac losses decreased exponentially from the initial value above 2 watts.

  • PDF

펄스전동기의 위치제어특성에 관한 해석적 연구 (Analytical Study of Position Control Characteristics of the Variable Reluctance Pulse motor)

  • 이윤종;장세훈;이용범
    • 전기의세계
    • /
    • 제28권1호
    • /
    • pp.59-66
    • /
    • 1979
  • The linearized models on per for mance dynamics of the pulse motor have been already proposed by many others. These models exhibit certain advantages of their own because of their simple formulation, but in many cases the models are proved to be inadequate for further accurate analysis of the motor dynamics, owing to impractical and rather rough assumptions in the derivation. In this study a dynamic state transition model is induced, using the equivalent circuit obtained from the operating principle of the variable reluctance pulse motor which turns out to be nonlinear equation. This nonlinear dynamic state equation is numerically analysed by the use of UNIVAC System/3(OS/3) digital computer at hand. In the course of the dynamic analysis of the performance characteristics of a testing motor, dependance of the inertia of rotor and load, the coefficient of viscous friction between rotor and housing, and the winding resistance of the stator is discussed and a comparative study of the machine constants is carried on as related to the design problem of the motor.

  • PDF

인버터 스위칭 써지에 의한 저압 유도전동기의 과도전압 분포해석 (Analysis of Overvoltage Distribution in Low-Voltage Induction Motor Due to Inverter Switching Surge)

  • 황돈하;김용주;이인우;배성우;김동희;노채균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1151-1153
    • /
    • 2003
  • In this paper, switching surge voltage distribution in stator windings of induction motor driven by IGBT PWM inverter is studied. To analyze the irregular voltage of stator winding, equivalent circuit model of inverter-cable-motor was proposed and high frequency parameter is computed by using finite element method (FEM). Electromagnetic transient program (EMTP) analysis of the whole system for induction motor and PWM inverter is proposed. In order to experiment, an induction motor, 380 [V], 50 [HP], with taps from one phase and a switching surge generator was built to consider the voltage distribution.

  • PDF

5kVA 초전도변압기의 동작특성 (Operational Characteristics of a 5kVA Superconducting Transformer)

  • 최경달;이상진;김동수;이지광;김동훈;차귀수;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.111-113
    • /
    • 1994
  • For the analysis of characteristics of a superconducting transformer, we designed and fabricated a 5kVA superconducting transformer with two kinds of secondary winding. Using the results of the open and short tests, we calculated the parameters of its equivalent circuit. We designed also a 5kVA conventional transformer with the same design conditions as the superconducting one. The performances of the superconducting transformer were compared with the performances of the designed conventional transformer and another 5kVA distribution transformer.

  • PDF

EMTP에 의한 고압 유도전동기의 진공차단기 스위칭서지 시뮬레이션 (The Simulation of VCB Switching Surge in the High Voltage Induction motors by EMTP)

  • 이은웅;김종겸;김일중;김택수;이성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1001-1003
    • /
    • 1993
  • Steep-fronted surges associated with motor witching cause relatively large turn-to-turn winding stress. In order to calculate the surge level at the motor terminals, equivalent circuits consist of three parts with power sources, load cable and motor constants. This paper presents switching surges phenomena occurred in a high voltgae induction motor witching by EMTP.

  • PDF

자기여자 현상 및 출력전압 안정화를 고려한 단상유도발전기의 설계방안 (A Design Scheme of Single-Phase Induction Generator Considering Self-excitation and Voltage Regulation)

  • 김철진;이관용;김영태;신흥교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1002-1004
    • /
    • 2005
  • This paper describes the performance analysis and design of single-phase self-excited induction generators. In this study, it is proposed to design the proper capacitance for self-excitation and voltage regulation, also. This methods are based on the induced MMF equations between main and the auxiliary winding. For the least influence between the two capacitors, the self-excited capacitor is selected under no load condition, while the series capacitor is designed under loaded condition. For the steady state analysis, the equivalent circuit of single-phase induction generators is used as circuit modeling using the double-revolving field theory. The validity of proposal methods and designed generator system will be confirmed by experimental and computed results.

  • PDF