• Title/Summary/Keyword: Equivalent Thickness

Search Result 600, Processing Time 0.032 seconds

The role of natural rock filler in optimizing the radiation protection capacity of the intermediate-level radioactive waste containers

  • Tashlykov, O.L.;Alqahtani, M.S.;Mahmoud, K.A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3849-3854
    • /
    • 2022
  • The present work aims to optimize the radiation protection efficiency for ion-selective containers used in the liquid treatment for the nuclear power plant (NPP) cooling cycle. Some naturally occurring rocks were examined as filler materials to reduce absorbed dose and equivalent dos received from the radioactive waste container. Thus, the absorbed dose and equivalent dose were simulated at a distance of 1 m from the surface of the radioactive waste container using the Monte Carlo simulation. Both absorbed dose and equivalent dose rate are reduced by raising the filler thickness. The total absorbed dose is reduced from 7.66E-20 to 1.03E-20 Gy, and the equivalent dose is rate reduced from 183.81 to 24.63 µSv/h, raising the filler thickness between 0 and 17 cm, respectively. Also, the filler type significantly affects the equivalent dose rate, where the redorded equivalent dose rates are 24.63, 24.08, 27.63, 33.80, and 36.08 µSv/h for natural rocks basalt-1, basalt-2, basalt-sill, limestone, and rhyolite, respectively. The mentioned results show that the natural rocks, especially a thicker thickness (i.e., 17 cm thickness) of natural rocks basalt-1 and basalt-2, significantly reduce the gamma emissions from the radioactive wastes inside the modified container. Moreover, using an outer cementation concrete wall of 15 cm causes an additional decrease in the equivalent dose rate received from the container where the equivalent dose rate dropped to 6.63 µSv/h.

Application of a Composite Skin Equivalent using Collagen and Acellular Dermal Matrix as the Scaffold in a Mouse Model of Full-thickness Wound (콜라겐과 무세포진피를 이용한 혼합형 인공피부 개발 및 쥐 모델에서 창상치료 적용)

  • Lee, Dong Hyuck;Youn, Jin Chul;Lee, Jung Hee;Kim, In Seop
    • KSBB Journal
    • /
    • v.29 no.1
    • /
    • pp.42-49
    • /
    • 2014
  • The aim of this study was to develop a composite human skin equivalent for wound healing. Collagen type1 and acellular dermal matrix powder were utilized as the scaffold with dermal fibroblasts and keratinocytes for the development of a composite human skin equivalent. Fibroblast maintained the volume of composite skin equivalent and also induced keratinocytes to attach and proliferate on the surface of composite skin equivalent. The composite human skin equivalent had a structure and curvature similar to those of real skin. Balb-C nu/nu mice were used for the evaluation of full-thickness wound healing effect of the composite human skin equivalent. Graft of composite skin equivalent on full-thickness wound promoted re-epithelialization and granulation tissue formation at 9 days. Given the average wound-healing time (14 days), the wound in the developed composite skin equivalent healed quickly. The overall results indicated that this three-dimensional composite human skin equivalent can be used to effectively enhance wound healing.

A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray (고에너지 방사선치료용 조직등가보상체에 관한 고찰)

  • CHOI Tae Jin;HONG Young Rak;LIM Charn Soo;JEUNG Ho Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF

Structural Analysis on Door Hinge of Car (자동차 도어 힌지의 구조해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.33-39
    • /
    • 2010
  • The thickness of original hinge model is changed for structural stability in this study. The front end with the largest deformation of 9.8813 mm or the rear middle part with the largest equivalent stress of 6082.6 MPa is respectively shown at door hinge. The lower part of joint pin head with the largest deformation of 0.17499 mm and the largest equivalent stress of 1540.2 MPa are shown. The advanced model with more thickness and stability is shown to have smaller displacement in half and smaller equivalent stress by 3 times by comparing with the original model.

A new lumped equivalent circuits for spiral inductor with metal thickness (금속의 두께를 고려한 나선형 인덕터의 집중형 등가 회로의 제안)

  • 오데레사;김흥수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.9
    • /
    • pp.21-27
    • /
    • 1997
  • Square spiral inductors are designed with EM program in accordance with the inner diameter and the metal thickness which is 0.2.mu.m and 20.mu.m respectively. We propose a parameter extraction method based on the S-parameter. Lumped equivalent circuits of spiral inductors are analyed with reflection coefficient S$_{11}$, of witch freqency rnage is 1~10GHz. When metal thickness is 0.2.mu.m, S$_{11}$ with EM simulation is not the same as S$_{11}$ that of SPICE simulation. So we suggests a new lumped equivalent circuits which compensate circuits. Te new lumped equivalent circuits are adequate for other inductor with small scale at high frequencies.ncies.

  • PDF

Assessment of the Measurement Method of the Bone Mineral Density on Cu-Equivalent Image (구리당량 영상작성에 의한 골밀도계측방법의 평가)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.101-108
    • /
    • 2000
  • Purpose : The effects of step numbers of copper wedge and exposure on the coefficient of determination (r²) of the conversion equation to Cu-equivalent image and on the Cu-equivalent value (mmCu) and it's coefficient of variation measured at each copper step and the mandibular premolar area were evaluated. Method: Digital image analyzing system consisted of scanner, personal computer, and a stepwedge with 10 steps of 0.03 mm copper in thickness as reference material was prepared for quantitative assessment of the bone mineral density. NIH image program was used for analyzing images. Results : The film having moderately high film density showed the discrepancy between the real thickness and the measured Cu-equivalent value of each copper step. The Cu-equivalent image was dependent on the determinational coefficient of the conversion equation than the coefficient of variance of the measured value. Conclusion : Obtaining conversion equation with high coefficient of determination and proper film exposure are supposed to be neccessary for quantitative assessment of bone density. Multiple steps in the range of the corresponding copper thickness to the bone density of the area to be measured should be prepared.

  • PDF

The Effect of the Area Ratio and the Distance Ratio on Bending Stiffness of Two Rectangular Plates Spot-Welded (면적비와 거리비가 점용접된 두 사각평판의 굽힘강성에 미치는 영향)

  • Han, Geun-Jo;Ahn, Sung-Chan;Shim, Jae-Joon;Han, Dong-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.425-430
    • /
    • 2001
  • The mechanical behavior of two rectangular plates spot-welded under bending is investigated in detail. The focus of the analysis is to evaluate the effect of thickness of reinforced plates with equivalent thickness. The results of this investigation are compared from detailed finite element analysis and experiments of the plates spot-welded for various parameters, such as aspect ratio, area ratio, and distance ratio of spot-welding points. The study is carried out using the equivalent thickness of the reinforced plates spot-welded.

  • PDF

A study on assessment of bone mass from aluminum-equivalent image by digital imaging system (디지털 영상 시스템을 이용한 알루미늄 당량화상에 의한 골량 측정에 관한 연구)

  • Kim Jin-Soo;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.87-97
    • /
    • 1997
  • The purpose of this study was to evaluate the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxyapatite block and hydroxyapatite mass. The results of this study were as follow; 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated(r²=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference(P<0.05) between them 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r²=0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different(P<0.05).

  • PDF

Shear Process and Frictional Characteristics in Down-end Milling

  • Lee, Young-Moon;Jang, Seung-Il
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.4
    • /
    • pp.19-24
    • /
    • 2003
  • In end milling process, which is characterized by the use of a rotating tool, the undeformed chip thickness varies periodically with phase change of the tool. Although many efforts have concentrated on the study of end milling process, the analysis of shear and chip-tool friction behaviors has not been reported. Recently, a model has been proposed to simulate the shear and friction characteristics of an up-end milling process in terms of the equivalent oblique cutting. In the current study, the varying undeformed chip thickness and the cutting forces in a down-end milling process are replaced with the equivalent ones of oblique cutting. Then it is possible to simulate the shear and the chip-tool friction characteristics of a down-end milling process. The proposed model has been verified through two sets of cutting tests i.e., down-end milling and the equivalent oblique cutting tests. The experimental results show that the proposed model is suitable to analyze the shear and chip-tool frictional characteristics of down-end milling process. The specific cutting energy decreases with increase in equivalent undeformed chip thickness in a down-end milling process.

The Effect of the Area Ratio and the Distance Ratio on Bending Stiffness of Two Rectangular Spot-Welded Plates (면적비와 거리비가 점용접된 두 사각평판의 굽힘강성에 미치는 영향)

  • Han, Geun-Jo;Ahn, Sung-Chan;Shim, Jae-Joon;Han, Dong-Seop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.3
    • /
    • pp.387-392
    • /
    • 2003
  • The mechanical behavior of two rectangular spot-welded plates under bending is investigated in detail. The equivalent thickness of spot-welded plates is introduced in this study and used in explaining the results. The focus of the analysis is to evaluate the effect of spot-welding from the view point of equivalent thickness. The investigation of deflection has been performed as comparing the result from finite element analysis with the measured data of the spot-welded plates for various parameters, such as aspect ratio, area ratio, and distance ratio of spot-welding points. The effect of spot-welding is as large as 62%(at r=1.0) when the area ratio of spot-welding point is just 4.52%.