• 제목/요약/키워드: Equivalent Circuit Method

검색결과 764건 처리시간 0.026초

DGS 구조를 이용한 DPDT 스위치 설계에 관한 연구 (A Study for DPDT Switch Design with Defected Ground Structure)

  • 안가람;정명섭;임재봉;조홍구;박준석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.132-138
    • /
    • 2005
  • In this paper a DPDT(Double-Pole Double Through) switch with defected ground structure(DGS) is proposed. The equivalent circuit for the proposed switch structure is derived according to based on equivalent circuit of proposed DGS unit structure. The equivalent circuit parameters of DGS unit are extracted by using the circuit analysis method. The on/off operation of the proposed switch is obtained by varying the capacitance of the varactor diode at the defected ground plane. In the case of ON state, the insertion loss of the fabricated DPDT was shown under 1dB. And in OFF state, we found the rejection characteristic over 20dB at the designed frequency 2.45GHz. The experimental results show excellent insertion loss at on state and isolation at off state.

A Simple Model for a DGS Microstrip Line with Stepped Impedance Slot-Lines

  • Woo, Duk-Jae;Lee, Taek-Kyung;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • 제15권1호
    • /
    • pp.26-30
    • /
    • 2015
  • In this paper, a simple equivalent circuit model for a defected ground structure (DGS) microstrip line with stepped impedance slot-lines in the ground plane is presented. In addition, an analytic expression for the resonance frequency of the proposed structure is derived. In equivalent circuit modeling, the capacitance and the inductance of the resonance circuit are evaluated from the dimensions of the etched pattern in the ground plane. The resonance frequencies calculated from the proposed method are compared with those obtained with an electromagnetic (EM) simulation.

Prediction of Change in Equivalent Circuit Parameters of Transformer Winding Due to Axial Deformation using Sweep Frequency Response Analysis

  • Sathya, M. Arul;Usa, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.983-989
    • /
    • 2015
  • Power transformer is one of the major and key apparatus in electric power system. Monitoring and diagnosis of transformer fault is necessary for improving the life period of transformer. The failures caused by short circuits are one of the causes of transformer outages. The short circuit currents induce excessive forces in the transformer windings which result in winding deformation affecting the mechanical and electrical characteristics of the winding. In the present work, a transformer producing only the radial flux under short circuit is considered. The corresponding axial displacement profile of the windings is computed using Finite Element Method based transient structural analysis and thus obtained displacements are compared with the experimental result. The change in inter disc capacitance and mutual inductance of the deformed windings due to different short circuit currents are computed using Finite Element Method based field analyses and the corresponding Sweep Frequency Responses are computed using the modified electrical equivalent circuit. From the change in the first resonant frequency, the winding movement can be quantified which will be useful for estimating the mechanical withstand capability of the winding for different short circuit currents in the design stage itself.

AT 급전계통 해석 알고리즘 연구 (A Study Algorithm of AT Feeding Systems)

  • 추동욱;김재철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권4호
    • /
    • pp.174-179
    • /
    • 2002
  • In this paper, the modified simulation algorithms of the Auto Transformer (AT) feeding electric train system were proposed. To obtain terminal voltage of train by using equivalent circuit or the AT feeding system, the iterative method is proposed for which determine the train voltages. The train voltages are iteratively calculated from the system voltage drop and line impedance. In the carte study, the proposed method is verified from actual operation data of the Kwa-Chon line. Also it is verified that the proposed method can be extent to the multi-train simulation tool. The terminal voltage of the multi-train can be calculated by using superposition principle and it is easily applied to the proposed method. Therefore, the proposed method can be a solution for the complexity of the circuit analysis in the existing methods.

Design, Analysis, and Equivalent Circuit Modeling of Dual Band PIFA Using a Stub for Performance Enhancement

  • Yousaf, Jawad;Jung, Hojin;Kim, Kwangho;Nah, Wansoo
    • Journal of electromagnetic engineering and science
    • /
    • 제16권3호
    • /
    • pp.169-181
    • /
    • 2016
  • This work presents a new method for enhancing the performance of a dual band Planer Inverted-F Antenna (PIFA) and its lumped equivalent circuit formulation. The performance of a PIFA in terms of return loss, bandwidth, gain, and efficiency is improved with the addition of the proposed open stub in the radiating element of the PIFA without disturbing the operating resonance frequencies of the antenna. In specific cases, various simulated and fabricated PIFA models illustrate that the return loss, bandwidth, gain, and efficiency values of antennas with longer optimum open stub lengths can be enhanced up to 4.6 dB, 17%, 1.8 dBi, and 12.4% respectively, when compared with models that do not have open stubs. The proposed open stub is small and does not interfere with the surrounding active modules; therefore, this method is extremely attractive from a practical implementation point of view. The second presented work is a simple procedure for the development of a lumped equivalent circuit model of a dual band PIFA using the rational approximation of its frequency domain response. In this method, the PIFA's measured frequency response is approximated to a rational function using a vector fitting technique and then electrical circuit parameters are extracted from it. The measured results show good agreement with the electrical circuit results. A correlation study between circuit elements and physical open stub lengths in various antenna models is also discussed in detail; this information could be useful for the enhancement of the performance of a PIFA as well as for its systematic design. The computed radiated power obtained using the electrical model is in agreement with the radiated power results obtained through the full wave electromagnetic simulations of the antenna models. The presented approach offers the advantage of saving computation time for full wave EM simulations. In addition, the electrical circuit depicting almost perfect characteristics for return loss and radiated power can be shared with antenna users without sharing the actual antenna structure in cases involving confidentiality limitations.

Analysis of Principle and Performance of a New 4DOF Hybrid Magnetic Bearing

  • Bai, Guochang;Sun, Jinji;Han, Weitao;Ren, Hongliang
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.379-386
    • /
    • 2016
  • To satisfy the requirement of magnetically suspended control moment gyroscope (MSCMG) that magnetic bearing can provide torque, a novel 4DOF hybrid magnetic bearing (HMB) with integrated structure was designed. Mathematical models of forces and torques are established by using equivalent magnetic circuit method. The current stiffness, displacement stiffness, tilting current stiffness and angular stiffness of the 4DOF hybrid magnetic bearing are derived by the mathematical models. Equivalent magnetic circuit method and finite element method (FEM) simulation results indicate that the force has a good linear relationship with both displacement and current, and the torque has a good linear relationship with angular displacement and current. The novel 4DOF HMB is capable of achieving control in both two radial translational degrees of freedom (DOF) and also two radial rotational DOFs. The 4DOF HMB is well adapted to MSCMG system, exhibiting advantages in the controllable DOF, light weight and easy to control.

등가자기회로를 활용한 콜레노이드 타입 선형 액츄에이터 설계 알고리즘 개발 (Development of the Design Algorithm Using the Equivalent Magnetic Circuit Method for Colenoid Type Electromagnetic Linear Actuator)

  • 한동기;장정환
    • 한국자기학회지
    • /
    • 제26권2호
    • /
    • pp.55-61
    • /
    • 2016
  • 본 논문에서는 설계변수 변화에 따른 특성을 빠른 시간 내에 파악할 수 있는 등가자기회로법(equivalent magnetic circuit method)을 활용하여 콜레노이드(colenoid) 타입의 선형 액츄에이터 설계 알고리즘을 제시하였다. 우선 선형 액츄에이터의 중요치수가 결정되면 등가자기회로법에 의해 슬롯 폭 비율 및 인가전류에 따른 클램핑력으로 파라미터 맵(parameter map)을 완성하고 이를 활용하여 효율적인 슬롯 폭 비율을 결정하였다. 또한 최대 클램핑력(clamping force)을 얻기 위해 극 폭 조절 알고리즘을 수행하여 최적의 극 폭 치수를 선정하였으며 이를 바탕으로 인가전류에 따른 클램핑력을 계산하여 40 kN 이상 출력하기 위한 최적의 극 수, 극 폭 치수 및 인가전류를 결정하였다. 제안된 설계 알고리즘은 최적설계 방법인 반응표면법(response surface method)과 비교하여 제안한 설계 알고리즘의 타당성을 검증하였다.

유한요소법을 이용한 유도전동기의 등가회로 정수 도출 (Calculation of the Equivalent Circuit Parameters of Induction Motor using Finite Element Analysis)

  • 심동하;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.55-57
    • /
    • 1997
  • This paper develops the advanced method for the calculation of the equivalent circuit parameters of induction motor. An Induction motor is magnetically coupled system. But the conventional motor (the permeance method) calculates the each component of parameters separately. And it highly depends on the experimental factors and experiences to compensate the errors due to the some assumptions. Rut the proposed method calculates the parameters fully from the results of 2 dimensional finite element analysis. So the complexity in geometry and the non linearity of induction motor can be considered. And the computational cost is reduced compared with the conventional field and circuit approach. The results are compared with parameters from the permeance method. And it is verified by the comparison with the experimental results.

  • PDF

Permanent Magnet Overhang Effect in Permanent Magnetic Actuator Using 3 Dimension Equivalent Magnetic Circuit network Method

  • Lim Seung-Bin;Kwon Ho;Kwon Sam-Young;Choi Seung-kil;Baek Soo-Hyun;Lee Ju
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.123-128
    • /
    • 2005
  • This paper presents an analysis of the permanent magnet overhang effect for the permanent magnetic actuator. Generally, the overhang is often used to increase the force density in permanent magnet machineries. The overhang is particularly profitable in reducing the volume after increasing the force density per volume when using the overhang effect of the permanent magnet. Therefore, the 3D Equivalent Magnetic Circuit Network Method (3D EMCN) has been used in this paper. According to the plunger position, the flux distribution per overhang length and the holding force are quantitatively compared. Furthermore, an appropriate length of the overhang has been proposed. To confirm the accuracy of the analysis method, the results of 2D FEM and 3D FEM are compared for the basic model.

정적 및 동적 단부효과를 고려한 선형 유도 전동기의 벡터제어 특성해석 (The Characteristic Analysis of Vector Control in a Linear Induction Motor Considering Static and Dynamic End Effects)

  • 김대경;권병일;우경일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.413-424
    • /
    • 2002
  • Recently, in the linear motion system, high performances are required In dynamic characteristics. Vector control method is capable of instantaneous thrust control can meet these high performance requirements. Linear induction motor(LIM) have static and dynamic end effects due to its finite core length, so that per-phase impedances are asymmetric and an air gap flux distribution is distorted. These points of the d-q axis equivalent circuit model considering both end effects is more complicated. This paper proposes the d-q axis equivalent circuit and the vector control method considering both static and dynamic end effects of the LIM. As a result, it is shown that the results of the equivalent circuit method(ECM) have a good agreement with those of the finite element method(FEM).