• Title/Summary/Keyword: Equivalent Area

Search Result 842, Processing Time 0.029 seconds

Modeling and Experimental Response Characterization of the Chevron-type Bi-stable Micromachined Actuator (Chevron형 bi-stable MEMS 구동기의 모델링 및 실험적 응답특성 분석)

  • 황일한;심유석;이종현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.203-209
    • /
    • 2004
  • Compliant bi-stable mechanism allows two stable states within its operation range staying at one of the local minimum states of the potential energy. Energy storage characteristics of the bi-stable mechanism offer two distinct and repeatable stable states, which require no power input to maintain it at each stable state. This paper suggests an equivalent model of the chevron-type bi-stable microactuator using the equivalent spring stiffness in the rectilinear and the rotational directions. From this model the range of spring stiffness where the bi-stable mechanism can be operated is analyzed and compared with the results of the FEA (Finite Element Analysis) using ANSYS for the buckling analysis, both of which show a good agreement. Based on the analysis, a newly designed chevron-type bi-stable MEMS actuator using hinges is suggested for the latch-up operation. It is found that the experimental response characteristics of around 36V for the bi-stable actuation for the 60$mu extrm{m}$ stroke correspond very well to the results of the equivalent model analysis after the change in cross-sectional area by the fabrication process is taken into account. Together with the resonance frequency experiment where 1760Hz is measured, it is shown that the chevron-type bi-stable MEMS actuator using hinges is applicable to the optical switch as an actuator.

Consequence Analysis of Gas Explosion in LPG Vessel Retail Store Which is Located around Apartment Complex (LPG 판매소에서 가스 폭발이 주위 아파트에 미치는 영향 평가)

  • Lee Su-Kyung;Bae Young-Bum;Oh Jeong-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.48-53
    • /
    • 2006
  • In case of fire and explosion which resulted from LP gas release of LPG vessel retail store, the populated area such as apartment complex is supposed to be damaged either partially or totally. To estimate the damage of LP gas explosion, we conducted quantitative risk analysis procedure as has been recommended by AIChE/CCPS. For incident scenario selection, event tree analysis was proposed. TNT equivalent method, SAFER Trace v.8.0 and probit model were also used for consequence analysis. The various methods and analyses which were performed in this study are presented with the effect zones in the layout.

  • PDF

Structure Borne Durability Design of a Vehicle Body Structure (차체구조의 구조기인 내구 설계)

  • 김효식;임홍재
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.109-121
    • /
    • 2004
  • This paper presents an optimal design method for structure-borne durability of a vehicle body structure. Structure-borne durability design requires a new design that can increase fatigue lives of critical areas in a structure and must prohibit transition phenomenon of critical areas that results from modification of the structure at the same time. Therefore, the optimization problem fur structure-borne durability design are consists of an objective function and design constraints of 2 types; type 1-constraint that increases fatigue lives of the critical areas to the required design limits and type 2-constraint that prohibits transition phenomenon of critical areas. The durability design problem is generally dynamic because a designer must consider the dynamic behavior such as fatigue analyses according to the structure modification during the optimal design process. This design scheme, however, requires such high computational cost that the design method cannot be applicable. For the purpose of efficiency of the durability design, we presents a method which carry out the equivalent static design problem instead of the dynamic one. In the proposed method, dynamic design constraints for fatigue life, are replaced to the equivalent static design constraints for stress/strain coefficients. The equivalent static design constraints are computed from static or eigen-value analyses. We carry out an optimal design for structure-borne durability of the newly developed bus and verify the effectiveness of the proposed method by examination of the result.

Numerical Analysis of Turbulent Swirling Cold-Flow in a Cyclonic Coal Gasifier (선회분류층형 석탄가스화기내의 비반응 난류 선회유동장 해석)

  • 이진욱;나혜령;윤용승
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • Turbulent swirling cold-flow in a cyclonic gasifier has been analyzed by numerical analysis. Comparison of two dimensional and three dimensional analyses has shown that concept of equivalent slit is appropriate for the two dimensionalization of three dimensional phenomena. Flow characteristics have been scrutinized by varying swirl number which is a crucial parameter in determining the flow pattern of the cyclonic gasifier. Reactive flow field has been estimated by using theoretical swirl number and equivalent slit width for reactive flow. Results show that proper flow field for the reactive coal gasification can be formed by controlling the exit area and azimuthal location of coal burners.

  • PDF

S-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 S영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Lee, J.T.;Han, H.H.;Kim, H.J.;Chong, D.I.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.143-144
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using S-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a S-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Z-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 Z영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Kim, K.Y.;Lee, J.T.;Han, H.H.;An, B.C.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.145-146
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using Z-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Development of Weight Type Snowfall Gauge and Observation (중량식 강설량계 개발과 관측)

  • Lee, Bu-Yong
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.255-261
    • /
    • 2009
  • We need water equivalent unit data of snowfall for the purpose of forecast and hydrology related research area. This study developed new method of automatic recording snowfall as weight unit. The instrument designed for measuring weight of snowfall by stain-gauge loadcell. Field test of instrument carried out at Daegwallyeong Obs. Station from 22 Jan. to 22 Feb. 2007. During observation period there is 15.3 cm snow depth and 16.0 mm of accumulated water equivalent depth at Daegwallyeong Obs. Station on 13 to 14 Feb. 2007. But the instrument of this study recorded 22.1 mm of water equivalent depth. It is not easy to explain difference between Daegwallyeong and this study. Because this study is only one case of comparison of snow measurement and there is very little amount of snow observation research. The density of snowfall calculated from 0.09 to $0.15g/cm^3$ from the observation data of 13 to 14 Feb. 2007. There is high relation between radar echo and snowfall amount measured by weight unit. It can supports forecast of snowfall and development of numerical model for forecast.

Stress Analysis of Blanking Plate Applied by Press (프레스에 의한 블랭킹 판재의 응력 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.66-71
    • /
    • 2008
  • The data of the deformation and the stress according to time are studied at upper model of press and lower model of the blanking plate applied by press with the width, length and height of 0.4 m and 0.6 m respectively. The press is pushing downward on the plate fixed at the lower floor. These data are compared and investigated through this study. By using these results, there is the maximum deformation at 4 corners in the lower plate model of aluminium alloy fixed at lower floor. This deformation incase of elapsed time of 0.6 second becomes 4 times as much as in case of elapsed time of 0.2 second. The quantity of deformation at the lower plate model becomes more than at the upper press model to the extent of 10%. At the lower plate model of aluminium alloy, there is the maximum Von-Mises equivalent stress at 4 corners and both sides of middle area on the lower plate model of aluminium alloy. This stress in case of elapsed time of 0.6 second becomes 6 times as much as in case of elapsed time of 0.2 second. The Von-Mises equivalent stress of lower plate model becomes 2 times as much as that of upper press mode.

  • PDF

LAG TIME RELATIONS TO CATCHMENT SHAPE DESCRIPTORS AND HYDROLOGICAL RESPONSE

  • Kim, Joo-Cheol;Kim, Jae-Han
    • Water Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.91-99
    • /
    • 2005
  • One of the most important factors for estimating a flood runoff from streams is the lag time. It is well known that the lag time is affected by the morphometric properties of basin which can be expressed by catchment shape descriptors. In this paper, the notion of the geometric characteristics of an equivalent ellipse proposed by Moussa(2003) was applied for calculating the lag time of geomorphologic instantaneous unit hydrograph(GIUH) at a basin outlet. The lag time was obtained from the observed data of rainfall and runoff by using the method of moments and the procedure based on geomorphology was used for GIUH. The relationships between the basin morphometric properties and the hydrological response were discussed based on application to 3 catchments in Korea. Additionally, the shapes of equivalent ellipse were examined how they are transformed from upstream area to downstream one. As a result, the relationship between the lag time and descriptors was shown to be close, and the shape of ellipse was presented to approach a circle along the river downwards. These results may be expanded to the estimation of hydrological response of ungauged catchment.

  • PDF

Assessment of seawater intrusion using geophysical well logging and electrical soundings in a coastal aquifer, Youngkwang-gun, Korea

  • Hwang Seho;Shin Jehyun;Park Inhwa;Lee Sangkyu
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.99-104
    • /
    • 2004
  • A combination of drilling, geophysical well logging, and electrical soundings was performed to evaluate seawater intrusion in Baeksu-eup, Youngkwang-gun, Korea. The survey area extends for over 24 $km^2$. To delineate the extent of seawater intrusion, 60 vertical electrical soundings (VES) have been carried out. Twelve wells were also drilled for the collection of hydrogeological, geochemical, and geophysical well logging data, to delineate the degree and vertical extent of seawater intrusion. To map the spatial distribution of seawater in this coastal aquifer, geophysical data and hydrogeochemical results were used, and the relation between the resistivity of groundwater and equivalent NaCl concentration was found. Layer parameters derived from VES data, various in-situ physical properties from geophysical well logging, and the estimated equivalent NaCl concentration were very useful for quantitative evaluation of seawater intrusion. Our approach for evaluating seawater intrusion can be considered a valuable attempt at enhancing the use of geophysical data.