• Title/Summary/Keyword: Equipment qualification

Search Result 152, Processing Time 0.026 seconds

A Study on Dynamic Analysis of Vertical Mixed-Flow Pump for Nuclear Power Plants (원자력 발전소용 입형 사류펌프의 동적해석에 관한 연구)

  • Seo, Y.S.;Lim, W.S.;Chung, H.T.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2006
  • This study introduces the seismic qualification of safety related equipments for nuclear power plants to verify the possibility of resonance in regard to the operating speed and the structural integrity due to external piping nozzle loads as well as seismic dynamic loads using El-Centro earthquake, which was occurred in the 1940's previously. As a first step, it is necessary to investigate the natural frequency of the vertical mixed flow pump in order to determine whether static or dynamic equipment comparing with seismic cut-off frequency, 33hz. Also the normal mode analysis was carried out with the introduction of seismic redesign straint at the middle of vertical pump to increase the natural frequency. In terms of structural integrity, the application of static analysis with normal, upset and faulted nozzle loads event was presented for the comparison of material allowable stress. Also the dynamic analysis was performed to show the design adequacy through the application to the case of El-Centro earthquake.

  • PDF

A study of the improvement of the national technical qualification practical evaluation method for National Competency Standards in the seed and horticulture industry

  • Hyun-Ho, Jang;Taek-Keun, Oh;Jwakyung, Sung
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.729-738
    • /
    • 2021
  • The purpose of this study was to suggest an improvement plan ultimately to develop practical evaluation methods for national technical qualifications in the field of seeds and horticulture based on the National Competency Standards. Through this, national technical qualifications can be strengthened in terms of professionalism in the seeds and horticulture field. In order to conduct this study, the national technical qualification currently in use was matched to certain competency units and competency unit elements of National Competency Standards. We then visited an industrial site to understand the practical factors related to the technical, facility and equipment aspects of the seeds and horticulture industrial field, after which a practical evaluation exam was developed. Also, for a feasibility study, a pilot test assessment was conducted for students majoring in seeds and horticulture, with a survey also conducted with field experts and an advisory committee consisting of experts in seeds and horticulture. Based on the results, by suggesting an improvement plan for a practical evaluation method leading to better national technical qualifications in the field of seeds and horticulture, it was shown to be possible to improve knowledge, technical, and literacy aspects. This can lead to the training of outstanding technical professionals. Ultimately, the results here are expected to contribute to the improvement of the seeds and horticulture industry.

Analysis of the commercial diving national qualification system for the introduction of a diving supervisor (잠수기능장 제도 신설을 위한 산업 잠수 국가자격체계 분석)

  • Sim, Kyoung-Bo;Cha, Joo-Hong;Kang, Sin-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.655-662
    • /
    • 2016
  • This study proposes that a diving supervisor, who can perform the role of both a field manager and a supervisor, be introduced in the national qualification system. The goal was achieved by surveying the general status of the commercial diving sector, including the statistics of an underwater construction company, commercial diving equipment operation condition, diver working hours, diver supply and demand status, and underwater construction market size. The national qualification and national competency standard (NCS) systems were also analyzed to deduce the role definition and work scope of the diving supervisor. Consequently, the following proposition is made: the diving supervisor should be an "on-site manager with the highest job skill in the commercial diving field, who can perform the on-site process management as well as guide, supervise, and educate project participants and serve as an intermediary between the contractor and the workers." The responsibilities of the diving supervisor are proposed to include "diving planning and operation of the diving team," "diving with surface-supplied air and mixed-gas diving system," "chamber operation," "underwater construction," and "ship salvage." The persistent issues in commercial diving sectors, such as diver career development, management, and worker supervision, are expected to be largely resolved with the introduction of this qualification.

State of the Japanese Security Industry and Its Implications for Korea (일본 시큐리티산업 현황과 한국의 시사점)

  • Ahn, Hwang Kwon
    • Convergence Security Journal
    • /
    • v.13 no.2
    • /
    • pp.75-84
    • /
    • 2013
  • In Japan, the Security Equipment Association takes the initiative in standardization, the preparation of installation standards and the management of the qualification system. This association is joined by electronic security companies, manufacturers and installers and makes research in security equipment, security alarm system and information security system. But, the Korea Security Association takes the initiative in the security industry in accordance with the security business act, but few electronic security companies that are the hub of the security market have joined the association yet. Currently, there is no organization in which electronic security companies, security equipment manufacturers and installers can participate together, and it's not possible for all the parties concerned to make a concerted effort for the development of security equipment under the circumstances.

Seismic Analysis of the Reflective Metal Insulation for Thermal Shielding of Main Equipments of Nuclear Power Plants (원전 설비 열차폐를 위한 반사형 금속단열재의 내진 해석)

  • Kim, Seung-Hyeon;Rhee, Huinam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.166-172
    • /
    • 2016
  • This paper deals with the seismic qualification of the reflective metal insulation for thermal shielding that is installed on the outer surfaces of the main equipment of the primary coolant system of a nuclear power plant. A small-scale model of the reactor pressure vessel, which has equivalent dynamic characteristics, was designed to be tested in domestic seismic testing facilities in the future. In this study, seismic analysis of the small-scale model installed with metal insulation was performed using equivalent static analysis and response spectrum analysis. The required Response Spectrum for main equipment of the primary coolant system of APR-1400 plant were considered to establish the enveloping response spectrum, which was applied to the seismic analysis model. The results from two seismic analysis methods were compared to show the structural adequacy of the metal insulator design against a safe shutdown earthquake. This study will form the basis for the seismic testing to support the seismic qualification of the reflective metal insulator.

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

Development of Response Spectrum Generation Program for Seismic Analysis of the Nuclear Equipment (원자력기기 내진해석응답스펙트럼 생성프로그램 개발)

  • Byun, Hoon-Seok;Kim, Yu-Chull;Lee, Joon-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.755-762
    • /
    • 2004
  • In our country, when the replacement for individual components of equipment in nuclear power plants is required, establishment of individual criteria i.e. Required Response Spectra(RRS) of seismic test/analysis for the component is very difficult because of the absence of Test Response Spectra(TRS) for the individual component to be replaced, from the existing qualification documents. In this case, it is required to perform the structural analysis for the nuclear equipment including the components to be replaced. After the structural analysis, Analysis Response Spectra(ARS) at the point of the component shall be generated and used for seismic test of the component. However, as of today, no standard program authorized for the response spectra generation by using the structural analysis exists in korea. Because of above reason, the STAR-Egs computer program was developed by using the method which calculates directly the expected response spectrum(frequency vs. acceleration type) of the selected points in the nuclear equipment with input spectrum(Required Response Spectra, RRS), based on the dynamic characteristics of the Finite Element(FE) model that is equivalent to the nuclear equipment. The STAR-Egs controls ANSYS/I-DEAS commercial software and automatically extract modal parameters of the FE model. The STAR-Egs calculates response spectrum using the established algorithm based on the extracted modal parameters, too. Reliance on the calculation result of the STAR-Egs was verified through comparison output with the result of MATLAB commercial software based on the identical algorithm. Moreover, actual seismic testing was performed as per IEEE344-1987 for the purpose of program verification by comparison of the FE analysis results.

  • PDF

Seismic demand estimation of electrical cabinet in nuclear power plant considering equipment-anchor-interaction

  • Cho, Sung Gook;Salman, Kashif
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1382-1393
    • /
    • 2022
  • This paper investigates the seismic behavior of an electrical cabinet considering the influence of equipment-anchor-interaction (EAI) that is generally not taken into consideration in a decoupled analysis. The hysteresis behavior of an anchor bolt in concrete was thereby considered to highlight this interaction effect. To this end, the experimental behavior of an anchor bolt under reversed cyclic loading was taken from the recently developed literature, and a numerical model for the anchor hysteresis was developed using the component approach. The hysteresis properties were then used to calibrate the multi-linear link element that is implemented as a boundary condition for the cabinet incorporating the EAI. To highlight this EAI further, the nonlinear time history analysis was performed for a cabinet considering the hysteresis behavior comparative to a fixed boundary condition. Additionally, the influence on the seismic fragility was evaluated for the operational and structural condition of the cabinet. The numerical analysis considering the anchor hysteresis manifests that the in-cabinet response spectra (ICRS) are significantly amplified with the corresponding reduction in the seismic capacity of 25% and 15% for an operational and structural safety condition under the selected protocols. Considering the fixed boundary condition over a realistic hysteresis behavior of the anchor bolt is more likely to overestimate the seismic capacity of the cabinet in a seismic qualification procedure.

A STUDY FOR ROUGHNESS FUNCTION OF FLAT PLATE WITH REYNOLDS NUMBER (레이놀즈수에 따른 평판 모델의 거칠기 함수에 관한 연구)

  • Joung, T.H.;Lee, J.H.;Kim, J.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.78-84
    • /
    • 2016
  • In this paper, turbulence models for considering roughness in the open source code(OpenFOAM) was investigated. Wall function in the RANS(Reynolds-averaged Navier - Stokes) turbulence model was modified considering roughness on the flat plate by using roughness function. Correlation between the first layer height in the CFD model and roughness height of the plate was observed, and the most proper roughness function, and the first layer height from the plate wall in the CFD analysis was suggested in this paper.

Equipment qualification for Excitation Control System for Emergency Diessel Generator (원전 비상디젤 발전기 여자시스템 기기검증)

  • Lee, Joo-Hyun;Lim, Ick-Heon;Ryu, Ho-Seon;Shin, Man-Su;Huh, Tae-Yaung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1911-1912
    • /
    • 2006
  • 원자력 발전소가 전력계통으로부터 분리되어 외부전원으로 발전소 내부의 주요 보조기기들을 운전할 수 없는 상황에서 비상디젤 발전기는 원자력발전소의 핵심 냉각펌프 등 전원을 공급하지 않으면 안 된다. 현재까지는 품질등급 Q-Class인 비상 발전기 여자시스템이 외국 기술에 전적으로 의존하여 공급되었는데 비상발전기가 차지하는 역할의 중요성으로 인한 품질활동 절차, 규제기관의 인허가 획득 등의 문제 때문에 비상 디젤발전기의 여자시스템이 현재까지 국산 연구개발이 이루어지지 않았다. 본 논문은 원전 비상디젤 발전기 여자시스템의 국산개발에 필요한 시스템의 기기 검증에 대한 내용을 기술하고자 한다.

  • PDF