• Title/Summary/Keyword: Equipment control

Search Result 4,115, Processing Time 0.03 seconds

Analysis on the EMC evaluating method for applying wireless communications in NPP (원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석)

  • Kang, SeungSeok;Lim, Tae Heung;Choo, Jaeyul;Kim, HyungTae;Kim, DaeHee;Byun, Gangil;Park, Jong Eon;Lee, Jun-Yong;Choo, Hosung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2221-2231
    • /
    • 2017
  • In this paper, we surveyed previous cases, network protocols (such as Wi-Fi, Zigbee, Z-wave, and WirelessHart) and propagation characteristics on the application of maintaining equipments for instrumentation and control (I&C) using wireless communication techniques inside the nuclear power plant (NPP). In addition, we compared and analyzed the difference of detailed regulations with respect to the electromagnetic interference (EMI) and radio frequency interference (RFI) in the Regulatory Guide 1.180 rev. 1 (RG. 1.180) for adopting the wireless communication techniques inside the NPP, and other regulations, such as MIL-STD 461E and IEC 61000-4, that are recognized in the KINS/RG-N03.09 (Rev. 2). Furthermore, we investigated evaluating factors about electromagnetic properties by considering indoor environments, wave scattering, shielding effectiveness, and the indoor wave attenuation model that were not included in the current electromagnetic compatibility regulation.

The implementation of cable path and overfill visualization based on cable occupancy rate in the Shipbuilding CAD (조선 CAD에서 선박의 Cable 점유율을 기반으로 Cable 경로 및 Overfill 가시화 구현)

  • Kim, Hyeon-Jae;Kim, Bong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.740-745
    • /
    • 2016
  • Cables are installed for tens of thousands of connections between various pieces of equipment to operate and control a commercial ship. The correct shortest-route data is necessary since these are complicated cable installations. Therefore, an overfill interval commonly exists in the shortest paths for cables as estimated by Dijkstra's algorithm, even if this algorithm is generally used. It is difficult for an electrical engineer to find the overfill interval in 3D cable models because the occupancy rate data exist in a data sheet unlinked to three-dimensional (3D) computer-aided design (CAD). The purpose of this study is to suggest a visualization method that displays the cable path and overfill interval in 3D CAD. This method also provides various color visualizations for different overfill ranges to easily determine the overfill interval. This method can reduce cable-installation man-hours from 7,000 to 5,600 thanks to a decreased re-installation rate, because the cable length calculation's accuracy is raised through fast and accurate reviews based on 3D cable visualization. As a result, material costs can also be reduced.

Characteristics and Deposition of CuInS2 film for thin solar cells via sol-gel method0 (Sol-gel법에 의한 박막태양전지용 CuInS2 박막의 증착과 특성)

  • Lee, Sang-Hyun;Lee, Seung-Yup;Park, Byung-Ok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.4
    • /
    • pp.158-163
    • /
    • 2011
  • $CuInS_2$ thin films were prepared using a sol-gel spin-coating method. That makes large scale substrate coating, simple equipment, easy composition control available. The structural and optical properties of $CuInS_2$ thin films that include less toxic materials (S) instead of Se, tetragonal chalcopyrite structure. Copper acetate monohydrate ($Cu(CH_3COO)_2{\cdot}H2O$) and indium acetate ($In(CH_3COO)_3$) were dissolved into 2-propanol and l-propanol, respectively. The two solutions were mixed into a starting solution. The solution was dropped onto glass substrate, rotated at 3000 rpm, and dried at $300^{\circ}C$ for Cu-In as-grown films. The as-grown films were sulfurized inside a graphite container box and chalcopyrite phase of $CuInS_2$ was observed. To determine the optical properties measured optical transmittance of visible light region (380~770 nm) were less than 30 % in the overall. The XRD pattern shows that main peak was observed at Cu/In ratio 1.0 and its orientation was (112). As annealing temperature increases, the intensity of (112) plane increases. The unit cell constant are a = 5.5032 and c = 11.1064 $\AA$, and this was well matched with JCPDS card. The optical transmittance of visible region was below than 30 %.

A study on the Combustion Control System and Thermal Efficiency (연소제어시스템과 열효율 향상 방안에 관한 연구)

  • Zhang, Yong-Nam;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.645-650
    • /
    • 2010
  • In this research, the problem of combustion and its system in Hyundai Heavy Industries and Sachuan Unison will be analyzed in order to provide some methods of thermal efficiency improvement and help to make a positive influence on fuel savings and their productivity. In forging industries, in order to improve the material properties of the industrial heating elements which are being used, depending on different operation conditions of system equipment and combustion systems, fuel consumption and material properties can get a profound influence. Thus, analyzing about combustion system characteristics of 100 tons heating furnace and heat treatment furnace which are in operation in Hyundai Heavy Industry will be done. In usual, air-fuel ratio is proper for capacity of burner installed in each heating device, otherwise burner gets an automatic turn down ratio. It has a profound influence on heating performance and precision of temperature because it is the fixed characteristics of every industrial furnace. Even if there are some methods to improve the heating performance of a furnace installed with a large capacity burner, it is very difficult to obtain the precision of temperature in maintenance interval. Based on this, performance of burner can be drove to best by improving combustion system. Proper Combustion characteristic for each heating interval was analyzed in heating furnace in Hyundai Heavy Industry. A project plan for improving fuel savings and increasing precision of temperature was presented in this research.

Convergent Awareness and Performance of the Standard Operating Procedure in Emergency Medical Technicians Serving as Paramedics (구급대원으로 활동하는 응급구조사의 표준작전절차에 대한 융복합적인 인지도와 수행도)

  • Hwang, Jeong-Hyeon;Lee, Hyeon-Ji
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.10
    • /
    • pp.105-114
    • /
    • 2017
  • The purpose of this study was to examine the convergent awareness of emergency medical technicians serving as paramedics on the standard operating procedure(SOP) and their performance of it. The subjects in this study were 400 selected emergency medical technicians who were working as paramedics, and SPSS 20.0 was employed to make an analysis. The findings of the study were as follows: As for the convergent awareness of the subjects, they were best aware of the prevention of respiratory infections, and they were least aware of hand hygiene. Concerning performance, they performed best in handling treatment equipment and ensuring staff safety, and they performed least well in terms of hand hygiene. Overall, they were rated higher in awareness than in performance. Second, regarding the influence of general characteristics, there were statistically significant differences in awareness according to age, gender and injury experience, and significant differences were found in performance according to career only. The convergent awareness of the emergency medical workers was positively correlated with their performance. Given the findings of the study, it's required to improve both the Standard Operating Procedure awareness and performance of emergency medical workers who serve as paramedics, and it's expected to make it possible to boost their performance when repeated education is provided with the kind of programs that aim at improving awareness.

Model Identification for Control System Design of a Commercial 12-inch Rapid Thermal Processor (상업용 12인치 급속가열장치의 제어계 설계를 위한 모델인식)

  • Yun, Woohyun;Ji, Sang Hyun;Na, Byung-Cheol;Won, Wangyun;Lee, Kwang Soon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.486-491
    • /
    • 2008
  • This paper describes a model identification method that has been applied to a commercial 12-inch RTP (rapid thermal processing) equipment with an ultimate aim to develop a high-performance advanced controller. Seven thermocouples are attached on the wafer surface and twelve tungsten-halogen lamp groups are used to heat up the wafer. To obtain a MIMO balanced state space model, multiple SIMO (single-input multiple-output) identification with highorder ARX models have been conducted and the resulting models have been combined, transformed and reduced to a MIMO balanced state space model through a balanced truncation technique. The identification experiments were designed to minimize the wafer warpage and an output linearization block has been proposed for compensation of the nonlinearity from the radiation-dominant heat transfer. As a result from the identification at around 600, 700, and $800^{\circ}C$, respectively, it was found that $y=T(K)^2$ and the state dimension of 80-100 are most desirable. With this choice the root-mean-square value of the one-step-ahead temperature prediction error was found to be in the range of 0.125-0.135 K.

Enhancement of PLED lifetime using thin film passivation with amorphous Mg-Zn-F

  • Kang, Byoung-Ho;Kim, Do-Eok;Kim, Jae-Hyun;Seo, Jun-Seon;Kim, Hak-Rin;Lee, Hyeong-Rag;Kwon, Dae-Hyuk;Kang, Shin-Won
    • Journal of Information Display
    • /
    • v.11 no.1
    • /
    • pp.8-11
    • /
    • 2010
  • In this study, a new thin films passivation technique using Zn with high electronegativity and $MgF_2$, a fluorine material with better optical transmittance than the sealing film materials that have thus far been reported was proposed. Targets with various ratios of $MgF_2$ to Zn (5:5, 4:6 and 3:7) were fabricated to control the amount of Zn in the passivation films. The Mg-Zn-F films were deposited onto the substrates and Zn was located in the gap between the lattices of $MgF_2$ without chemical metathesis in the Mg-Zn-F films. The thickness and optical transmittance of the deposited passivation films were approximately 200 nm and 80%, respectively. It was confirmed via electron dispersive spectroscopy (EDS) analysis that the Zn content of the film that was sputtered using a 4:6 ratio target was 9.84 wt%. The Zn contents of the films made from the 5:5 and 3:7 ratio targets were 2.07 and 5.01 wt%, respectively. The water vapor transmission rate (WVTR) was determined to be $38^{\circ}C$, RH 90-100%. The WVTR of the Mg-Zn-F film that was deposited with a 4:6 ratio target nearly reached the limit of the equipment, $1\times10^{-3}\;gm^2{\cdot}day$. As the Zn portion increased, the packing density also increased, and it was found that the passivation films effectively prevented the permeation by either oxygen or water vapor. To measure the characteristics of gas barrier, the film was applied to the emitting device to evaluate their lifetime. The lifetime of the applied device with passivation was increased to 25 times that of the PLED device, which was non-passivated.

A study on the new developmental direction for Intelligent Network Service (지능망서비스의 발전방향에 관한 연구)

  • 박민수;최수길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.43-49
    • /
    • 2000
  • That modem society is an information society, information society has placed a high value on information and knowledge. Therefore, modem civilization depends largely on information and knowlege so the most valuable sources of all intelligence activities. This paper was studied on the new developmental direction for intelligent network service. The results of this study is as follow: first, intelligent network service must be systematic development. Second, intelligent network service must be promoted, presenting the development and establishment direction in future society. Third, intelligent network service must be able to unify ail the networks. Fourth, intelligent network service must be development for customers. Fifth, the cost of intelligent network service is determined by Telecommunication Reguration Commission. Sixth, the number system of intelligent network service must be accomplished by number system for future

  • PDF

Cyber-Lecture Management System based on XML (XML 기반의 사이버 강좌관리 시스템)

  • Kim, Hye-Young;Kim, Hwa-Sun;Kim, Heung-Sik;Kim, Sang-Gyun;Choi, Heung-Kook
    • The KIPS Transactions:PartA
    • /
    • v.10A no.5
    • /
    • pp.529-538
    • /
    • 2003
  • The speedy development of the world-wide web is rapidly growing the internet-based tools for the remote instruction. In interchanging and expressing the information of one another on the web, it is produced through the form of HTML(Hyoertext Text Markup Language). However, the structural disadvantage of the HTML is becoming to require a powerful XML(eXtensible Markup Language) which can store all the sphere of data, and transform them into another form. Nevertheless, because the powerful XML(eXtensible Markup Language). However necessary that XML standard should be applied appropriately. Because existing lecture data of cyber education sites cannot be shared, the users should passively use only the functions offered by cyber school. To solve the problem of this limit, in this study, the standardized data structure for XML is defined, and system model for processing between the server and the client is provided. By storing the lecture data of cyber education sites as XML on the web, stored data came to be reused without changing on any site. In the view of Users, they could used the Internet service with equipment that they want at any place and any time. To control any kinds of CK\LMS(Cyber Lecture Management System) for Administrator and Users, we offered a variety of Multimedia applications and an easy interface and built a new style of CLMS. Therefore, by strong and extracting the data related with the virtual education of the secondary school through the form of XML, for the effective interchange and sharing of the information, maximum utilization of the information can be achieved.

Properties of Strength and Stress-Strain of Recycled-Plastic Polymer Concrete (폐플라스틱 재활용 폴리머콘크리트의 강도와 응력-변형률 특성)

  • Jo Byung-Wan;Koo Jakap;Park Seung-Kook
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.329-334
    • /
    • 2005
  • The use of Polymer Concrete (PC) is growing very rapidly in many structural and construction applications such as box culverts, hazardous waste containers, trench lines, floor drains and the repair and overlay of damaged cement concrete surfaces in pavements, bridges, etc. However, PC has a defect economically because resin which be used for binder is expensive. Therefore the latest research is being progressed to replace existing resin with new resin which can reduce the high cost. Here, Polymer concrete using the recycled PET(polyethylene terephthalate) has some merits such as decrease of environmental destruction, decrease of environmental pollution and development of new construction materials. The variables of this study are amount of resin, curing condition and maximum size of coarse aggregate to find out mechanic properties of this. Stress-strain curve was obtained using MTS equipment by strain control. The results indicated that modulus of elasticity was increased gradually in an ascending branch of curve, as an increase of resin content. Compressive strength was the highest for resin content of $13\%$. And Compressive strength was increased as maximum size of coarse aggregate increases. The strain at maximum stress increases with an increase of resin content and size of coarse aggregate. For the descending branch of stress-strain curve the brittle fracture was decreased when it was cured at the room temperature compared to high temperature.