• 제목/요약/키워드: Equal pressure method

검색결과 87건 처리시간 0.032초

수정된 등압법을 이용한 매니폴드의 유량분배 (Flow Distribution in Manifold Using Modified Equal Pressure Method)

  • 예휘열;김두환;이관수;차우호
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.176-185
    • /
    • 2009
  • A general flow distribution model and a simple process of numerical analysis, which can be applied to multi-pass systems with manifolds, are presented. A numerical procedure, namely a modified equal pressure method based on the discrete model, was developed to predict flow rates at branch tubes. The predicted pressure distribution agreed well with the previous research with the average error less than 11%. A parametric study was performed to demonstrate the effect on the flow distribution.

수정된 등압법을 이용한 매니폴드의 유량분배 (Flow distribution in manifold using modified equal pressure method)

  • 예휘열;김두환;이관수;차우호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2280-2285
    • /
    • 2008
  • A general flow distribution model and a simple process of numerical analysis, which can be applied to multi-pass systems with manifolds, are presented. Correlations are derived from the discrete model, and numerically calculated using a modified equal pressure method. The predicted pressure distribution agrees well with the available experimental results of other researchers with the average error less than 2% for 10 branch manifolds, and 4% for 20 branch manifolds. A parametric study is performed to demonstrate the effect on the flow distribution.

  • PDF

동차선형 유한요소와 Fractional Step방법을 이용한 열유동장의 해석 (Analysis of Thermal flow Field Uing Equal Order Linear Finite Element and Fractional Step Method)

  • 최형권;유정열
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2667-2677
    • /
    • 1995
  • A new numerical algorithm using equal order linear finite element and fractional step method has been developed which is capable of analyzing unsteady fluid flow and heat transfer problems. Streamline Upwind Petrov-Galerkin (SUPG) method is used for the weighted residual formulation of the Navier-Stokes equations. It is shown that fractional step method, in which pressure term is splitted from the momentum equation, reduces computer memory and computing time. In addition, since pressure equation is derived without any approximation procedure unlike in the previously developed SIMPLE algorithm based FEM codes, the present numerical algorithm gives more accurate results than them. The present algorithm has been applied preferentially to the well known bench mark problems associated with steady flow and heat transfer, and proves to be more efficient and accurate.

등압법과 T-method를 이용한 공조시스템 배관 설계에 관한 연구 (A Study on the Duct Design of HVAC System Using the Equal Friction Method and the T-method)

  • 박준석;최길환;조대승
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.435-443
    • /
    • 2009
  • Optimal duct design of a HVAC system requires analysis technology to accurately evaluate its pressure losses, flow rate and velocity for making a compromised design among fan capacity and duct size affecting initial manufacturing and operation costs, and noise induced by the HVAC system. In this paper, we carry out initial duct design using the equal friction method. Using the result, the T-method is applied for accurate analysis of flow rate. Then, the duct size is modified using the difference between the required and the calculated flow rate, which can guarantee required flow rate, reduce the pressure unbalance among duct paths and lead to select optimal fan performance. To verify the validity and effectiveness of the proposed design method, an example for HVAC system design including noise analysis is demonstrated.

마그네슘의 등통로각압축 공정 시 변형 및 파괴 거동에 대한 유한요소해석 (Analysis for Deformation and Fracture Behavior of Magnesium during Equal Channel Angular Pressing by the Finite Element Method)

  • 윤승채;팜쾅;김형섭
    • 대한금속재료학회지
    • /
    • 제46권3호
    • /
    • pp.144-149
    • /
    • 2008
  • Equal channel angular pressing (ECAP) has been studied intensively over the decade as a typical top-down process to produce ultrafine/nano structured materials. ECAP has successfully been applied for a processing method of severe plastic deformation to achieve grain refinement of magnesium and to enhance its low ductility. However, difficult-to-work materials such as magnesium and titanium alloys were susceptible to shear localization during ECAP, leading to surface cracking. The front pressure, developed by Australian researchers, can impose hydrostatic pressure and increase the strain level in the material, preventing the surface defect on workpiece. In the present study, we investigated the deformation and fracture behavior of pure magnesium using experimental and numerical methods. The finite element method with different ductile fracture models was employed to simulate plastic deformation and fracture behavior of the workpiece.

Finite element based total response analysis of rectangular liquid containers against different excitations

  • Kalyan Kumar Mandal
    • Ocean Systems Engineering
    • /
    • 제13권1호
    • /
    • pp.57-77
    • /
    • 2023
  • In the present study, the total hydrodynamic pressure exerted by the fluid on walls of rectangular tanks due to horizontal excitations of different frequencies, is investigated by pressure based finite element method. Fluid within the tanks is invisid, compressible and its motion is considered to be irrotational and it is simulated by two dimensional eight-node isoparametric. The walls of the tanks are assumed to be rigid. The total hydrodynamic pressure increases with the increase of exciting frequency and has maximum value when the exciting frequency is equal to the fundamental frequency. However, the hydrodynamic pressure has decreasing trend for the frequency greater than the fundamental frequency. Hydrodynamic pressure at the free surface is independent to the height of fluid. However, the pressure at base and mid height of vertical wall depends on height of fluid. At these two locations, the hydrodynamic pressure decreases with the increase of fluid depth. The depth of undisturbed fluid near the base increases with the increase of depth of fluid when it is excited with fundamental frequency of fluid. The sloshing of fluid with in the tank increases with the increase of exciting frequency and has maximum value when the exciting frequency is equal to the fundamental frequency of liquid. However, this vertical displacement is quite less when the exciting frequency is greater than the fundamental frequency.

등압식 바닥 분출공조시스템의 기류 분출 상태에 관한 연구 (A Study on Outlet of Draft Pattern for Equal Pressure Method Underfloor Air Distribution System)

  • 최영식;손원득
    • 한국산업융합학회 논문집
    • /
    • 제16권2호
    • /
    • pp.29-33
    • /
    • 2013
  • This study has been conducted to propose an optimal design guidance of underfloor air distribution system by examining air pattern and proper exhaust status of floor plenum using CFD (Computational Fluid Dynamics). Simulation shows deficient air pattern and exhaust status at BPG (Bypass Grille) of the current design. As a means to find an alternative design, four cases have been developed and tested. Case 1, 2 and 3 show similar results in comparison to the current design. However, case 4 shows improved air pattern and exhaust status at BPG(Bypass Grille), and has been chosen as the optimal alternative.

Pure-Zr의 ECAP 공정에서 마찰에 따른 금형의 소성 변형 (Plastic Deformation of Die due to Friction during Equal Channel Angular Pressing)

  • 배강호;권기환;채수원;권숙인;김명호;황성근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.804-807
    • /
    • 1997
  • Recently equal-channel angular pressing (ECAP) has been employed to produce ultra-fine grain size materials. In this paper pure-Zirconium is considered due to its applicability to nuclear reactors. Among many process parameters of ECAP frictional effect on the plastic deformation of die has been investigated. The back pressure effect due to friction increases the stress level of die especially at the crossing area of channels, which may result in plastic deformation of die. The finite element method has been employed to investigate this issue.

  • PDF

말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구 (Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph)

  • 정인철;신태민;윤형로
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권8호
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.

20대 여성의 브래지어 치수설정과 의복압에 관한 연구 (A Study on Establishment of Brassiere Size and Clothing Pressure for the Twenties-aged Women)

  • 박유신;임영자
    • 복식
    • /
    • 제52권8호
    • /
    • pp.15-27
    • /
    • 2002
  • To set the measurements of bras for women in their 20s, considering the comfortableness in wearing and tightness, this paper conducted a questionnaire survey concerning breasts and bras as well as measurements of body and contact surface pressure. Easier and more accurate method of determining cup sizes based on the breast circumference is recommended to make up for the problem of current bra size system that can falsely measure cup sizes. Lower chest circumference was set at 5 cm equal intervals, and the breast circumference applicable to the cup size was set starting from the standard, 18 cm (A-cup), at 2 cm equal intervals, which gave the best coverage (88.1%).