• Title/Summary/Keyword: Equal interval

Search Result 167, Processing Time 0.028 seconds

Study on the Development of Heat Recovery Ventilator (폐열회수형 환기장치 개발에 관한 연구)

  • Cho, Dong-Hyun;Lim, Tae-Woo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.3
    • /
    • pp.383-389
    • /
    • 2007
  • To evaluate the performance of heat exchanger with rotating porous plates, the experimental investigation was carried out under various conditions. With an equal interval of 18 mm inside the heat exchanger, the rotating porous plates are mounted. The hot and cold airs enter at opposite ends of heat exchanger and exchange heat each other. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10 mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18 mm. As a result of the measurement, the temperature distribution inside heat exchanger was constant as the hot air temperature of inlet is low. It was found that the heat transfer rate does not depend on the variation of RPM at the lower temperature of inlet. The heat transfer rate at the higher temperature of inlet increased a little with the increase in RPM.

Study on the Irregular Shape Rolling Process (비대칭 형상 압연 공정에 대한 연구)

  • 김용철;김동진;김병민
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.98-106
    • /
    • 1999
  • In this study cold rolling process for the irregular cross-sectional shape has been investigated. The product analyzed in present study is the steel cutter, which is frequently used to cut the desired shape on leather. Because steel cutter always has a irregular cross-section, after rolling process the workpiece is severely bended to every direction. The bending of the workpiece affects the processed performed after rolling such as heat treatment and grinding, then that of the workpiece becomes more severe. In this study, therefore, to prevent the bending of the workpiece to the left and right sides. rigid-plastic finite element method has been utilized and in order to find optimal roll geometry rapidly, one dimensional equal interval search technique has been also introduced. By using both rigid plastic finite element method and optimum technique, cold rolling process for the irregular cross-sectional shape has been successfully investigated.

Analysis of the Radiation Pattern of Conformal Array Transducers (곡면 배열 트랜스듀서의 방사 특성 해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.431-438
    • /
    • 2010
  • The radiation pattern of conformal transducers installed on a curved surface is likely to be complicated depending on the array pattern on the curved surface. In this research, the acoustic sources constituting a conformal transducer are arrayed in equi-angle, equi-interval, and geodesic dome forms, and the radiation pattern function of each of the array geometries has been derived, and therewith the radiation pattern has been analyzed for each array geometry. Based on the analysis result, we have determined the equi-interval array geometry that provides the widest beam width with the lowest side lobe level among the three array geometries. Results of the present work are expected to be utilized to the design of conformal transducer structures.

A Study on the Safety Frame Interval of Pipe Houses in Kyungpook Region (경북지방 파이프하우스의 안전골조간격에 관한 연구)

  • 이현우;이석건
    • Journal of Bio-Environment Control
    • /
    • v.4 no.2
    • /
    • pp.195-202
    • /
    • 1995
  • As the pipe houses were constructed by imitation and routine without a structural design by now, they were often destructed by a strong wind or a heavy snowfall. The purpose of this study was to provide the basic data for the safety structural design of the pipe houses in Kyungpook region to prevent meteorological disaster. It was shown that the change of frame interval according to the safety factor under the wind load was similar that under the snow load. But the safety frame interval under the snow load was approximately 0.5-0.6m greater than that under the wind load for equal safety factor. Therefore, it seemed that the maximum safety frame interval was to be decided by the snow load. The frame of the pipe houses in Seungju region was structurally stable under the design snow load in recurrence intervals of 8-15years, but was unstable in Kolyong region.

  • PDF

A note on distance measure and similarity measure defined by Choquet integral on interval-valued fuzzy sets (구간치 퍼지집합 상에서 쇼케이적분에 의해 정의된 거리측도와 유사측도에 관한 연구)

  • Jang, Lee-Chae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.4
    • /
    • pp.455-459
    • /
    • 2007
  • Interval-valued fuzzy sets were suggested for the first time by Gorzafczany(1983) and Turksen(1986). Based on this, Zeng and Li(2006) introduced concepts of similarity measure and entropy on interval-valued fuzzy sets which are different from Bustince and Burillo(1996). In this paper, by using Choquet integral with respect to a fuzzy measure, we introduce distance measure and similarity measure defined by Choquet integral on interval-valued fuzzy sets and discuss some properties of them. Choquet integral is a generalization concept of Lebesgue inetgral, because the two definitions of Choquet integral and Lebesgue integral are equal if a fuzzy measure is a classical measure.

Bootstrap Confidence Intervals of Classification Error Rate for a Block of Missing Observations

  • Chung, Hie-Choon
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.4
    • /
    • pp.675-686
    • /
    • 2009
  • In this paper, it will be assumed that there are two distinct populations which are multivariate normal with equal covariance matrix. We also assume that the two populations are equally likely and the costs of misclassification are equal. The classification rule depends on the situation when the training samples include missing values or not. We consider the bootstrap confidence intervals for classification error rate when a block of observation is missing.

A Study on the Earthwork Calculation for Reclamation (埋立을 위한 土工量 계산에 관한 硏究)

  • Mun, Du-Yeoul
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.61-70
    • /
    • 1995
  • The purpose of this paper is to calculate the excavation volume of unequal interval grid using nonlinear boundary in eathwork volume determination for reclamation of the foreshore. A congruence area formula by first and third equation is compared with trapezoidal, simpson formulas to earthwork volume. And nonlinear spot level method of unequal interval grid is compared with linear and nonlinear spot level method of equal interval grid excavation volume. As a result algorithm of derived area and volume formula should provide a better accuracy than linear and nonlinear spot level currently in use. Practical application of each method to the excavation volume is illustrated by digital elevation model of aerial photogrammetry and model test of aquarium.

  • PDF

Some characterizations of a mapping defined by interval-valued Choquet integrals

  • Jang, Lee-Chae;Kim, Hyun-Mee
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.66-70
    • /
    • 2007
  • Note that Choquet integral is a generalized concept of Lebesgue integral, because two definitions of Choquet integral and Lebesgue integral are equal if a fuzzy measure is a classical measure. In this paper, we consider interval-valued Choquet integrals with respect to fuzzy measures(see [4,5,6,7]). Using these Choquet integrals, we define a mappings on the classes of Choquet integrable functions and give an example of a mapping defined by interval-valued Choquet integrals. And we will investigate some relations between m-convex mappings ${\phi}$ on the class of Choquet integrable functions and m-convex mappings $T_{\phi}$, defined by the class of closed set-valued Choquet integrals with respect to fuzzy measures.

Just noticeable difference of autocorrelation function (ACF) parameters of refrigerator noise (냉장고 소음 ACF 요소의 최소인지한계량 조사)

  • You, Jin;Jeong, Choong-Il;Jeon, Jin-Yong;Cho, Moon-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1442-1445
    • /
    • 2007
  • Just noticeable differences (jnds) of autocorrelation function (ACF) parameters - Phi (0), Tau 1 and Phi 1 - of household refrigerator noise were investigated by psychoacoustical analyses. Phi (0) of five refrigerators' noise was changed with equal (${\pm}$) interval level of 0.5-1.0 dB up to five intervals by manipulating sound pressure level of the noise. Tau 1 and Phi 1 were varied with equal (${\pm}$) interval of around 0.10 ms and 0.02, respectively. Pitch shifting and strengthen methods were applied for the Tau 1 and Phi 1 variations. As results of subjective evaluations, about 2.0 dB was shown as jnd of Phi (0). The values of 0.30 ms and 0.06 were found as jnds of Tau 1 and Phi 1, respectively. The jnd results of each ACF parameter can be applied to explain substantial amount of sound quality (SQ) enhancement in the SQ prediction indices which were proposed in the authors' previous study [Sato et al. (2007) J. Acoust. Soc. Am.].

  • PDF

Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates (다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가)

  • Lim, T.W.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF