선박간 이격거리에 따른 WIND SHIELDING EFFECT 검토 (The Study on Wind Shielding Effects According to Distance Between Two Ships)

  • 구명준;하문근;최재웅;배준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1413-1417
    • /
    • 2004
  • The environmental elements which naturally occur can result in structural damages and operating faults of vessels under the navigation and mooring. These primary factors are considered as wind, waves and tide. In order to investigate wind shielding effects with respect to wind load conditions between two ships which face the wind directly or slantingly to the wind direction, this numerical simulation was preferred in terms of the variation of wind loads according to different distances, wind velocities and wind directions between two ships. The results were proved to be quite reasonable, comparing with experimental data from Danish Maritime Institute, and the report, "Environmental Conditions And Environmental Loads" published by Det Norske Veritas.

  • PDF

Modeling of RC Frame Buildings for Progressive Collapse Analysis

  • Petrone, Floriana;Shan, Li;Kunnath, Sashi K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권1호
    • /
    • pp.1-13
    • /
    • 2016
  • The progressive collapse analysis of reinforced concrete (RC) moment-frame buildings under extreme loads is discussed from the perspective of modeling issues. A threat-independent approach or the alternate path method forms the basis of the simulations wherein the extreme event is modeled via column removal scenarios. Using a prototype RC frame building, issues and considerations in constitutive modeling of materials, options in modeling the structural elements and specification of gravity loads are discussed with the goal of achieving consistent models that can be used in collapse scenarios involving successive loss of load-bearing columns at the lowest level of the building. The role of the floor slabs in mobilizing catenary action and influencing the progressive collapse response is also highlighted. Finally, an energy-based approach for identifying the proximity to collapse of regular multi-story buildings is proposed.

유량-부하량 관계식을 이용한 용담호 유입하천의 영양염류 유입량 변동특성 (Variational Characteristics of Nutrient Loading in Inflow Streams of the Yongdam Reservoir Using Flow-Loading Equation)

  • 김태근
    • 환경영향평가
    • /
    • 제15권2호
    • /
    • pp.129-138
    • /
    • 2006
  • The measurements of nutrient and runoff in 4 streams have been performed before and after the rainfall in order to estimate nutrient loads in the Yongdam reservoir. The equations for the relationship between the flow and the loads in each stream could be estimated by the regression analysis. R2 of TN showed the range from 0.95 to 0.99 and the range of R2 for TP was 0.90~0.95 based on the results of the regression analyses. In 2002, total loadings from the upstream to the Yongdam reservoir were TN 1,175 ton/year, TP 69 ton/year. There were 64.9% of TN and 72.3% of TP during 4 months as the flood season. Due to the rainfall, the load of TP was higher than one of TN in Yongdam reservoir.

비점오염 취약지역을 고려한 관리우선순위 설정 (Prioritization of Control Areas using Vulnerable Areas by Non-point Source Pollution)

  • 김홍태;신동석;김용석
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.11-18
    • /
    • 2014
  • Vulnerable areas by non-point source pollution and prioritizing control areas were researched using hydrological and geomorphological data, non-point source loads, and water quality data. Using overlay analysis, vulnerable areas were graded with various scenarios. Vulnerable areas were selected near the metro city with impermeable landuse because non-point source loads and water quality data had influence on overlay analysis to rank vulnerable area. Analysis scenarios and weighted values can be changed under regional characteristics and given conditions.

해양 수직 파일(Vertical Pile)에 작용하는 환경 하중하의 응력 해석 기법 비교 (Comparison of stress analysis tools for ocean vertical pile under environmental loads)

  • 조철희;김병환;김두홍
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.121-127
    • /
    • 2001
  • To investigate the stability and integrity of offshore structures, it is necessary to estimates the significant ocean environmental loadings. They include hydrostatic pressure, wind, wave, current, tide, ice, earthquake, temperature, marine growth and scouring. Waves are of major importance among them because of the large forces acting on submerged parts of the structure caused by accompanying water motions. For the comparison of stress and deflection analysis tools, a vertical pile is applied under environmental loads. The analysis is concerned with SACS(Structural Analysis Computer System), ANSYS and C program. SACS and C program have nearly the same results but not ANSYS. This study shows the comparison of results obtained from 3 different approaches.

  • PDF

Performance of R/C Bridge Piers under Seismic Loads

  • Kang, Hong-Duk;Kang, Young-Jong;Yoon, Young-Soo
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.35-46
    • /
    • 2000
  • A research program was initiated at the University of Colorado at Boulder to develop computational models that can be used for seismic risk assessments. To assess the overall performance of bridge structures including the nonlinear effects of bridge piers, the research focused on two levels of capabilities, i.e. global and local pier levels. A 3-D concrete model was used to evaluate the behavior of individual piers under combined axial, bending, and shear loadings using 3-D finite element analysis. Whereby the response curve reached the peak strength of the R/C column under the constant axial and monotonically increasing lateral loads. Experimental results on reinforced concrete bridge piers, which were obtained at the University of California at San Diego were used to validate the seismic performance of bridge piers at the two levels, globa1 and local.

  • PDF

고해상도 영상자료를 이용한 실제토지이용에 따른 지목면적 및 부하량 산정 (Calculation of Land Category Area and Pollution Loads according to Real Land Usage using High Resolution Satellite Image)

  • 박재홍;이수웅;박주현;류덕희;정동일;최혜미;전우송
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.193-204
    • /
    • 2009
  • The study was conducted investigation on land of D-dong in N city which is an urban area and D myeon of N city which is a suburban area, based on high resolution satellite image, to find out actual land usage. As for D-dong in N city, different rate between actual usage and official land information was 0.5~4.8% in terms of 5 major land types (paddy field, farm, ground, forest, and others). D myeon in N city posted 1.4~8.4%, which is higher than that of its counterpart. As for unit load, "land" which is large in terms of load presented a big difference between official information and actual usage. On the other hand, the levels of paddy, field, forest and others posted only small changes in load. In case of T-P, in particular, unit of each land type is lower than BOD and T-N, showing almost no changes in pollution loads.

건물용도에 따른 개별오수처리시설의 운영실태에 관한 연구 (A Survey on Operating State of ISWTP according to Building Use Type)

  • 권은미;김종석;정욱진
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.337-341
    • /
    • 2005
  • It is difficult to use average sewage water quality as a design parameter for the individual sewage wastewater treatment plant(ISWTP), because sewage water quality is very various according to the building use type. So, in this study, we estimated daily, seasonal and weekly trend of sewage water quality and flow rate in various kind of building to comprehend operating state of ISWTP. The sewage water quality and flow rate were higher in the business building than household building. The seasonal difference of the water quality was not detected but that of flow rate was high. The flow rate of the sewage in the business building was higher in summer than in other seasons and in weekend than in weekday. The treatment efficiency of IWSTP was about $70{\sim}80%$ with BOD, $40{\sim}50%$ with TN and TP, which was very low. The unit loads of the individual house were 36.05 gpcd with BOD, 37.91 gpcd with SS, 23.91 gpcd with T-N, and 7.90 gpcd with T-P respectively, and those values were higher than other studies. It is because, as distinct from other studies, sewage water quality was monitored at the inlet point of the IWSTP in this study. We can use this results as an one of basic parameters for the design of IWSTP.

수질오염총량관리를 위한 유역모형의 유달 과정 재현방안 연구 (Study on Representation of Pollutants Delivery Process using Watershed Model)

  • 황하선;이한필;이성준;안기홍;박지형;김용석
    • 한국물환경학회지
    • /
    • 제32권6호
    • /
    • pp.589-599
    • /
    • 2016
  • Implemented since 2004, TPLC (Total Pollution Load Control) is the most powerful water-quality protection program. Recently, uncertainty of prediction using steady state model increased due to changing water environments, and necessity of a dynamic state model, especially the watershed model, gained importance. For application of watershed model on TPLC, it needs to be feasible to adjust the relationship (mass-balance) between discharged loads estimated by technical guidance, and arrived loads based on observed data at the watershed outlet. However, at HSPF, simulation is performed as a semi-distributed model (lumped model) in a sub-basin. Therefore, if the estimated discharged loads from individual pollution source is directly entered as the point source data into the RCHRES module (without delivery ratio), the pollutant load is not reduced properly until it reaches the outlet of the sub-basin. The hypothetic RCHRES generated using the HSPF BMP Reach Toolkit was applied to solve this problem (although this is not the original application of Reach Toolkit). It was observed that the impact of discharged load according to spatial distribution of pollution sources in a sub-basin, could be expressed by multi-segmentation of the hypothetical RCHRES. Thus, the discharged pollutant load could be adjusted easily by modification of the infiltration rate or characteristics of flow control devices.

수질오염총량관리 대상물질 선정을 위한 하천수질 평가 (Evaluation of Stream Water Quality to Select Target Indicators for the Management of Total Maximum Daily Loads)

  • 박준대;박재홍;오승영;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.630-640
    • /
    • 2013
  • It is one of the most critical steps identifying impaired waterbodies exactly in the selection of target water quality indicators for the management of Total Maximum Daily Loads (TMDLs). Excess ratio and excess level were applied and analyzed by the stream zone basis in order to evaluate water impairment for Nakdong, Geum, Youngsan and Seomjin rivers. Each river basin was divided into stream zones in the light of its watershed and waterbody characteristics. Selected water quality parameters discussed in this study were pH, DO, BOD, COD, SS, T-P, T-Coli and F-Coli. The excess ratios of the water quality parameters were used to discriminate water bodies that did not meet water quality standards. The excess levels were used to classify the degradation of water quality. The excess ratios and the excess levels to the water quality criteria of the medium influence areas were used for each stream zone. The results indicate that the excess ratios and the excess levels are varied on the stream zone in each river basin. Three parameters, pH, DO and SS, met water quality standards in all stream zones. The other five parameters indicated very high excess ratios in most waterbodies, and especially T-P and T-Coli revealed to be very high excess levels in some waterbodies. These parameters could be considered as major target indicators for the management of TMDLs.