• 제목/요약/키워드: Environmental Resistance Performance

검색결과 469건 처리시간 0.023초

화재시 온도증가로 인한 RC 슬래브의 강도 특성 (Strength Properties of RC Slabs under Elevated Temperatures from Fire)

  • 임초롱;정철헌;김유석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

환경시험방법에 의한 내화도료의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performace of Intumescent Coating System by Environmental Testing Procedure)

  • 박수영;성시창;최동호;김대회;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system by environmental testing procedure.

  • PDF

고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성 (Behavior Characteristics of PCM Infilled Floor System at Elevated Temperature)

  • 박민재;민정기;윤성원;주영규
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.33-41
    • /
    • 2017
  • Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it.

Evaluation of Filtration Efficiency and Inhalation Airflow Resistance of Uncertified Masks in Asian Countries

  • Sohyun Kang;Soomin Kim;Ji Soo Kim;Gayoung Lee;Annisa Utami Rauf;Kraichat Tantrakarnapa;Shih-Chun Candice Lung;Kiyoung Lee
    • 한국환경보건학회지
    • /
    • 제50권4호
    • /
    • pp.267-273
    • /
    • 2024
  • Background: During the coronavirus pandemic, masks played a critical role in preventing respiratory infections. While the performance of masks such as KF-certified masks and N95 masks was evaluated and managed by the authorities, the performance of common masks was not. Objectives: This study aimed to evaluate the performance of uncertified masks in four Asian countries against certification standards (Korean KF80, KF94, and US N95). Methods: Thirty uncertified mask products from Indonesia, 20 from South Korea, 26 from Taiwan, and 30 from Thailand were purchased to perform performance evaluations. The uncertified masks included disposable dental masks, cloth masks, and children's masks. Filtration efficiency and inhalation airflow resistance tests were conducted according to Korean KF80, KF94, and US N95 protocols. Results: None of the 106 identified masks complied with the KF94 standard. A few complied with the KF80 standard: four from Indonesia, four from South Korea, 13 from Taiwan, and 16 from Thailand. Some of the masks met the N95 standard: one from Indonesia, three from South Korea, two from Taiwan, and one from Thailand. Conclusions: Since many uncertified masks did not comply with performance standards, wearing them might not have provided sufficient protection. Performance of uncertified masks could provide critical information for next pandemic management.

세라믹 막여과 정수처리 공정에서 유입수질 및 막여과유속이 막오염 형성에 미치는 영향 (Effects of membrane fouling formation by feed water quality and membrane flux in water treatment process using ceramic membrane)

  • 강준석;박서경;이정준;김한승
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.77-87
    • /
    • 2018
  • In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than $5m^3/m^2{\cdot}day$. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.

Characteristics of high performance reinforced concrete barriers that resist non-deforming projectile impact

  • Dancygier, A.N.
    • Structural Engineering and Mechanics
    • /
    • 제32권5호
    • /
    • pp.685-699
    • /
    • 2009
  • Current research and development of high performance concrete, together with study of phenomena that are pertinent to impact resistance, have lead to a new generation of barriers with improved properties to resist impact loads. The paper reviews major properties and mechanisms that affect impact resistance of concrete barriers as per criteria that characterize the resistance. These criteria are the perforation limit, penetration depth and the amount of front and rear face damage. From the long-known, single strength parameter that used to represent the barriers' impact resistance, more of the concrete mix ingredients are now considered to be effective in determining it. It is shown that the size and hardness of the aggregates, use of steel fibers and micro-silica have different effects on performance under impact and on the resistance. Additional pertinent phenomena, such as the rate and size effects, confinement and local versus global response, are pointed out with their reference to possible future developments in the design of impact resisting concrete barriers.

Evaluation of The Moment Resistance Joint Strength of Larch Glulam Using Glass Fiber Reinforced Wood Plate

  • Song, Yo-Jin;Jung, Hong-Ju;Park, Hyun-Ho;Lee, Hak-Young;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.571-578
    • /
    • 2014
  • As a way of developing wooden joint development, a glass fiber reinforced wood plate was manufactured to replace a steel plate. Also, the fracture toughness was evaluated. Through application to a cantilever-type specimen made of a column and a beam, the moment resistance performance was evaluated. For the fracture toughness specimen of the wood plate, 12 types were manufactured by varying the combination of a main member (veneer and plywood) and reinforcement (glass fiber sheet and glass fiber cloth). The results of the fracture toughness test indicated that the 5% yield load of the specimen using plywood was 18% higher than that of the specimen using veneer, and that the specimen reinforced by inserting glass fiber sheets between testing materials (Type-3-PS) had the highest average 5% yield load 4841 N. Thus, a moment resistance strength test was performed by applying Type-3-PS to a column-beam joint. The results of the test indicated that compared to the specimen using a steel plate and a drift pin (Type-A), the maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a drift pin (Type-B) was 0.79; and that a rupture occurred in the wood plate due to high stiffness of the drift pin. The maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a glass fiber reinforced wooden laminated pin (Type-C) was 0.67, which showed low performance. However, unlike Type-A, a ductile fracture occurred on Type-C, and the load gradually decreased even after the maximum moment.

Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

  • Kim, In-Ju
    • Safety and Health at Work
    • /
    • 제9권1호
    • /
    • pp.17-24
    • /
    • 2018
  • Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents.

전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향 (Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System)

  • 장재경;박혜민;김태영;양윤석;여정진;강석원;백이;권진경
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권5호
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.

옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구 (A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs)

  • 오상근;곽규성;선윤숙;권시원
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.