Browse > Article
http://dx.doi.org/10.5658/WOOD.2014.42.5.571

Evaluation of The Moment Resistance Joint Strength of Larch Glulam Using Glass Fiber Reinforced Wood Plate  

Song, Yo-Jin (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Jung, Hong-Ju (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Park, Hyun-Ho (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Lee, Hak-Young (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Hong, Soon-Il (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Publication Information
Journal of the Korean Wood Science and Technology / v.42, no.5, 2014 , pp. 571-578 More about this Journal
Abstract
As a way of developing wooden joint development, a glass fiber reinforced wood plate was manufactured to replace a steel plate. Also, the fracture toughness was evaluated. Through application to a cantilever-type specimen made of a column and a beam, the moment resistance performance was evaluated. For the fracture toughness specimen of the wood plate, 12 types were manufactured by varying the combination of a main member (veneer and plywood) and reinforcement (glass fiber sheet and glass fiber cloth). The results of the fracture toughness test indicated that the 5% yield load of the specimen using plywood was 18% higher than that of the specimen using veneer, and that the specimen reinforced by inserting glass fiber sheets between testing materials (Type-3-PS) had the highest average 5% yield load 4841 N. Thus, a moment resistance strength test was performed by applying Type-3-PS to a column-beam joint. The results of the test indicated that compared to the specimen using a steel plate and a drift pin (Type-A), the maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a drift pin (Type-B) was 0.79; and that a rupture occurred in the wood plate due to high stiffness of the drift pin. The maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a glass fiber reinforced wooden laminated pin (Type-C) was 0.67, which showed low performance. However, unlike Type-A, a ductile fracture occurred on Type-C, and the load gradually decreased even after the maximum moment.
Keywords
glass fiber reinforced wood plate; fracture toughness; moment resistance performance; glulam;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Garg, A.C. 1986. The Fracture Mechanics of Some Graphite Fibre-Reinforced Epoxy Laminates, Part 1: Quasi-Isotropic Laminates. Composites. 17: 141-149.   DOI   ScienceOn
2 Kim, K.H. 2012. Bolted Connection Strength of Glass Fiber Reinforced Glulam. Ph.D. Thesis, Kangwon National University, Korea.
3 Leonard, L.W.H., Wong, K.J., Yousif, B.F. 2009. Fracture behaviour of glass fiber-reinforced polyester composit. Proceedings of the institution of Mechanical Engineers. Part L: Journal of Materials Design and Applications. 223(2): 83-89.   DOI
4 Park, J.C., Shin, Y.J., Hong, S.I. 2009. Bending Performance of Glulam Beams Reinforced with Carbon Fiber-Reinforced Plastics Bonded with Polyvinyl Acetate-Based Adhesive. Journal of The Korean Wood Science and Technology, 37(4): 364-371.
5 Park, J.C., Shin, Y.J., Hong, S.I. 2009. Bonding Performance of Glulam Reinforced with Glass Fiber-Reinforced Plastics. Journal of The Korean Wood Science and Technology. 37(4): 357-363.   과학기술학회마을
6 Song, Y.J., Jung, H.J., Kim, D.K., Kim, S.I., Hong, S.I. 2014. Performance Evaluation for Bending Strength and Tensile Type Shear Strength of GFRP Reinforced Laminated Wooden Pin. Journal of The Korean Wood Science and Technology. 42(3): 258-265.   과학기술학회마을   DOI   ScienceOn
7 Uchisako, T., Tokuda, M. 2009. Rational Timber Frame Structure Jointed with Glass Fiber Reinforced Nylon Plate I. Basic Shear Properties of a Drift-Pin Joint to Static Loads. Mokuzai Gakkaishi, 55(4): 226-234.   DOI
8 ASTM D5045-99. 1999. Standard Test Methods for Plane-Strain Fracture Toughness and Strain Energy Release Rate of Plastic Materials.