• 제목/요약/키워드: Entrance Speed

검색결과 146건 처리시간 0.023초

고속도로 연속 유입연결로 접속단간의 이격거리 설계기준에 관한 연구 (Design Guideline for Successive Entrance Ramp Spacing)

  • 장재남;장명순
    • 대한교통학회지
    • /
    • 제14권3호
    • /
    • pp.155-172
    • /
    • 1996
  • This study is to analyze speed variation at merging section of successive entrance ramp and to suggest design criterion of ramp spacing at successive entrance ramp in urban area. The major findings are as follows ; (1) The relationship between the speed at merging section of successive entrance ramp and the distance from the merging point represents concave curve. (2) The 85 percentile speed(S) at outside lane (lane 1) is modeled S = 49.5 + 355.7(D/Q) - 0.94(D2/Q) + 6.78(D/AL2) where, D = Distance from merging point(m), Q = Lane 1 volume(vph) AL2 = Acceleration length at second entrance ramp(m) (3) The more traffic volume and the shorter acceleration length of the second entrance ramp, longer ramp terminal spacing is needed.

  • PDF

고속철도 터널입구에서 형성되는 압축파의 특성에 관한 연구 (Characteristics of High-Speed Railway Tunnel Entry Compression Wave)

  • 김희동;김태호;이종수;김동현
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.234-242
    • /
    • 1999
  • Flow phenomena such as the pressure transients Inside a high-speed railway tunnel and the Impulsive waves at the exit of the tunnel are closely associated with the characteristics of the entry compression wave, which is generated by a train entering the tunnel. Tunnel entrance hood may be an effective means for alleviating the Impulsive waves and pressure transients. The objective of the current work is to explore the effects of the train nose shape and the entrance hood on the characteristics of the entry compression wave. Numerical calculations using the method of characteristics were applied to one-dimensional, unsteady, compressible flow field with respect to high-speed railway/tunnel systems. Two types of the entrance hoods and various train nose shapes were employed to reveal their influences on the entry compression wave for a wide range of train speeds. The results showed that the entry compression wave length increases as the train nose becomes longer and the train speed becomes lower. The entry compression wave length in the tunnel with hood becomes longer than that of no hood. Maximum pressure gradient in the compression wavefront reduces by the entrance hood. The results of the current work provide useful data for the design of tunnel entrance hood.

고속철도의 터널입구 형상변황에 따른 압력파동 현상에 관한 수치적 연구 (Numerical Study on the Effects of Pressure Wave Propagation for Tunnel Entrance Shape Change in High-Speed Railways)

  • 목재균;백남욱;유재석;최윤호
    • 한국자동차공학회논문집
    • /
    • 제5권2호
    • /
    • pp.50-59
    • /
    • 1997
  • When a front head of train enters a tunnel at a high speed, compression wave is generated at tunnel entrance due to the confinement effect and propagated along the tunnel with sound of speed. The propagated compression wave is reflected at tunnel exit due to abrupt pressure change at passage. The reflected wave is expansion pressure wave. And when the rear head of train goes through the tunnel entrance, another expansion pressure wave is generated and propagated along the tunnel. The pressure drop occurs seriously around train when the two expansion pressure waves come cross on train in the tunnel. In order to reduce the pressure drop, the compression wave front must be controlled because the intensity and magnitude of pressure drop is nearly proportional to that of compression wave at tunnel entrance. This study relates to reduction of the pressure wave gradient with respect to tunnel entrance shape change with various kind of angle and rounding. The results show characteristics of wave propagation in tunnel, usefulness of characteristic curve to estimate proper time domain size in numerical study and measuring time in actual experiment. Also rounding is contributed to improve pressure wave front even if its radius is very small at tunnel entrance. In order to improve of pressure wave front at tunnel entrance, proper angle is prefered to rounding with big radius and an angle of around 14$^{\circ}$ is recommended according to this simulations, And it is expected to reduce additional pressure drop in tunnel when the location and the size of the internal space for attendant equipment are considered in advance.

  • PDF

입구후드가 고속철도 터널입구의 압축파에 미치는 영향 (Effect of Tunnel Entrance Hood on Entry Compression Wave)

  • 김희동;김태호;김동형
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.58-68
    • /
    • 1999
  • The entry compression wave, which forms at the entrance of a high-speed railway tunnel, is closely related to the pressure transients in the train/tunnel systems as well as an impulsive noise appearing at the exit of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Optimum hood shape necessary to reduce the pressure transients and impulsive noise was found to be of an abrupt type hood with its cross-sectional area 2.5 times the tunnel area. It is believed that the current results are highly useful in predicting the effects of entrance hoods and in choosing the shape of proper hood.

고속철도에서 슬릿커버 완충공의 터널 미기압파 저감성능 (Experimental Study on the Slit Cover Hood for Reducing the Micro Pressure Waves in High-Speed Train-Tunnel Interfaces)

  • 김동현;민동호
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.758-765
    • /
    • 2001
  • Purpose of the present is to investigate the food configuration at a tunnel entrance for reducing the micro pressure wave that is generated according to train speed. Two configurations were examined for tunnel of 0.5 km length. The experimental results show that a slit cover hood installed at the entrance of the tunnel reduces the maximum micro pressure wave by 41.2%, and a configuration with a slit cover hood installed at the entrance and a 45$^{\circ}$slanted portal at the exit of the tunnel suppresses it by 47.7%.

미기압파에 의한 터널 출구 소음 저감을 위한 고속철도 터널 형상 개선에 관한 연구 (A Study on Tunnel Entry Design Considering the Booming Noise Resulting from Micro-Pressure Wave)

  • 목재균;최강윤;유재석
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.959-966
    • /
    • 1997
  • In general, the booming noise intensity at tunnel exit is strongly related to the gradient of the compression wave front created by high speed train entering the tunnel. This paper presents some results in relation with the compression wave front produced when the high speed train enters a tunnel. Four kinds of tunnel entrance shape with real dimensions were studied to investigate the formation of compression wave front inside tunnel by train entering tunnel. Computations were carried out using three-dimensional compressible Euler equation with vanishing viscosity and conductivity of fluid. According to the results, the flow disturbances occured at tunnel entrance were eliminated by tunnel hood with same cross sectional area. The compression wave front is formed completely at 30-40m from tunnel entrance. The maximum pressure gradient of compression wave front is reduced by 29.8% for the inclined tunnel hood and reduced by 21.5% for the tunnel hood with holes at the top face with tunnel without hood. The length of the inclined hood is 15m and the length of the hood with holes is 20m.

  • PDF

미기압파에 의한 터널출구소음저감을 위한 고속철도 터널형상개선에 관한 연구 (A study on tunnel entry design considering the booming noise resulting from micro-pressure wave)

  • 목재균;최강윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.627-635
    • /
    • 1997
  • In general, the booming noise intensity at tunnel exit is strongly related to the gradient of the compression wave front created by high speed train entering the tunnel. This paper presents some results in relation with the compression wave front produced when the high speed train enters a tunnel. Four kinds of tunnel entrance shape with real dimensions were studied to investigate the formation of compression wave front inside tunnel by train entering tunnel. Computations were carried out using three-dimensional compressible Euler equation with vanishing viscosity and conductivity of fluid. According to the reslts, the flow disturbance occured at tunnel entrance were eliminated by tunnel hood with same cross sectional area. The compression wave front is formed completely at 30-40m from tunnel entrance. The maximum pressure gradient of compression wave front is reduced by 29.8% for the inclined tunnel hood and reduced by 21.5% for the tunnel hood with holes at the top face with tunnel without hood. The length of the inclined hood is 15m and the length of the hood with holes is 20m.

  • PDF

고속도로 톨게이트 진입제어용 효과분석 툴의 개발 (Development of an Effectiveness Analysis Tool for Freeway Tollgate Entrance Control)

  • 이환필;윤일수;오영태;김수희
    • 한국ITS학회 논문지
    • /
    • 제11권3호
    • /
    • pp.1-12
    • /
    • 2012
  • 본 연구에서는 고속도로 교통류 관리를 위해 현재 시행중인 톨게이트 진입제어기법에 대해서 교통관리자가 교통상황의 변동에 따라 능동적으로 대처할 수 있도록 정보를 제공할 수 있는 톨게이트 진입제어의 효과분석 툴을 개발하였다. 개발을 위해 현재 시행되고 있는 한국도로공사 톨게이트 진입제어기법의 문제점을 진단하여 검지체계, 혼잡판단지표, 판단기준, 혼잡관리단위를 개선하였고 톨게이트 진입제어를 위한 절차를 수립하였다. 개발효과분석 툴은 개선된 톨게이트 진입제어 시행절차를 구현할 수 있도록 크게 교통상황 진단, 톨게이트 조절, 통행속도 산출 부문으로 구성하였다. 효과분석을 위해 톨게이트 진입제어과정을 구현한 효과분석 툴을 이용, 분석을 수행하였으며 혼잡기준속도를 80km/h로 적용하였을 때 톨게이트 진입제어 미시행시 및 기존 한국도로공사방안에 비해 통행속도가 각 21.5%, 8.8% 개선되는 것을 확인하였다.

고속철도 터널 입구후드에 관한 수치해석적 연구 (Numerical Study on High-Speed railway Tunnel Entrance Hood)

  • 김희동;김동현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.604-611
    • /
    • 1998
  • High-speed railway trains entering and leaving tunnels generate finite amplitude pressure wave which propagate back and forth along the tunnels, reflecting at the open ends of the tunnels and at other discontinuities such as ventilation shafts and the train themselves. In present day railways, the magnitudes of the pressure waves are much too small to cause structual damage, but they are a serious potential source of aural discomport for passengers on unsealed trains. Almost always do the pressure waves propagating along the tunnels lead to a hazardous impulse noise near the exit portal of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Desirable hood shape for reduction of the pressure transients and impulse noise was found to be of abrupt type hood with its cross-sectional area 2.5times the tunnel area.

  • PDF

2차선 유입연결로의 서비스 수준별 가속차선 길이 산정 기준 (Guideline of Acceleration Length by Level of Service for Two Lane Entrance Ramp)

  • 문대승;장명순
    • 대한교통학회지
    • /
    • 제14권3호
    • /
    • pp.75-90
    • /
    • 1996
  • The objective of study is to examine relationship between traffic flow characteristics of two lane entrance terminal and acceleration length, and to suggest the acceleration length by level of service. The relationship between the speed ratio and the distance from the ramp appeared to be a quadratic concave from. In the case of two lane entrance ramp, the acceleration length is suggested as 1.4~2.0 times longer than the acceleration length of one lane entrance ramp. It is also recommended that acceleration length for two lane entrance ramp should be designed according to the level of service at the right most lane (level of service A : 1.4 B : 1.6 C : 1.8 D : 2.0 times of the one lane entrance ramp acceleration length) on freeway.

  • PDF