• 제목/요약/키워드: Engineering Program

검색결과 13,052건 처리시간 0.043초

POTENTIAL APPLICATIONS FOR NUCLEAR ENERGY BESIDES ELECTRICITY GENERATION: A GLOBAL PERSPECTIVE

  • Gauthier, Jean-Claude;Ballot, Bernard;Lebrun, Jean-Philippe;Lecomte, Michel;Hittner, Dominique;Carre, Frank
    • Nuclear Engineering and Technology
    • /
    • 제39권1호
    • /
    • pp.31-42
    • /
    • 2007
  • Energy supply is increasingly showing up as a major issue for electricity supply, transportation, settlement, and process heat industrial supply including hydrogen production. Nuclear power is part of the solution. For electricity supply, as exemplified in Finland and France, the EPR brings an immediate answer; HTR could bring another solution in some specific cases. For other supply, mostly heat, the HTR brings a solution inaccessible to conventional nuclear power plants for very high or even high temperature. As fossil fuels costs increase and efforts to avoid generation of Greenhouse gases are implemented, a market for nuclear generated process heat will be developed. Following active developments in the 80's, HTR have been put on the back burner up to 5 years ago. Light water reactors are widely dominating the nuclear production field today. However, interest in the HTR technology was renewed in the past few years. Several commercial projects are actively promoted, most of them aiming at electricity production. ANTARES is today AREVA's response to the cogeneration market. It distinguishes itself from other concepts with its indirect cycle design powering a combined cycle power plant. Several reasons support this design choice, one of the most important of which is the design flexibility to adapt readily to combined heat and power applications. From the start, AREVA made the choice of such flexibility with the belief that the HTR market is not so much in competition with LWR in the sole electricity market but in the specific added value market of cogeneration and process heat. In view of the volatility of the costs of fossil fuels, AREVA's choice brings to the large industrial heat applications the fuel cost predictability of nuclear fuel with the efficiency of a high temperature heat source tree of Greenhouse gases emissions. The ANTARES module produces 600 MWth which can be split into the required process heat, the remaining power drives an adapted prorated electric plant. Depending on the process heat temperature and power needs, up to 80% of the nuclear heat is converted into useful power. An important feature of the design is the standardization of the heat source, as independent as possible of the process heat application. This should expedite licensing. The essential conditions for success include: ${\bullet}$ Timely adapted licensing process and regulations, codes and standards for such application and design ${\bullet}$ An industry oriented R&D program to meet the technological challenges making the best use of the international collaboration. Gen IV could be the vector ${\bullet}$ Identification of an end user(or a consortium of) willing to fund a FOAK

입체사진측량기법의 암반절리조사에 대한 적용성 연구 (Study on Applicability of Stereophotogrammetry to Rock Joint Survey)

  • 한정훈;송재준
    • 터널과지하공간
    • /
    • 제17권2호
    • /
    • pp.139-151
    • /
    • 2007
  • 입체사진측량기법이란 대상면에 대하여 두 장 이상의 스테레오 영상을 취득하고 이 영상을 해석함으로써 대상면에 대한 정보론 추출하는 방법이다. 본 연구에서는 기존의 수작업에 의한 암반절리조사 방법에 대한 대안으로서, 입체사진측량기법을 암반절리조사에 적용하여 절리 정보론 추출하였고 그 결과를 비교, 분석함으로써 암반절리조사에의 적용성을 평가하였다. 검증은 실내 모형 시험을 통한 검증과 실제 암반에 대한 검증을 통하여 수행되었다. 현장 적용시 기선거리비가 해석 결과에 미치는 영향을 평가하기 위한 촬영 및 분석을 수행하였고, 해석 자료의 정확도를 향상시키기 위하여 절리 대상면을 분할 확대 촬영하였다. ShapeMetriX 3D프로그램을 이용한 실내 모형 시험 결과, 3차원 공간 좌표의 실측치를 이용한 결과와 비교하여 경사각 및 경사방향에 대하여 모두 ${\pm}5^{\circ}$ 이내의 편차를 보임을 확인하였다. 또한 영상 취득시 폐색 구간이 발생하지 않도록 촬영한다면, 기선거리비가 해석 결과에 미치는 영향이 크지 않음을 알 수 있었다. 따라서 분할 확대 촬영을 통한 취득 자료의 분석은 효율적인 방법으로 판단된다.

수리적 굴착손상영역에서의 지하수유동 특성에 관한 연구 (Groundwater Flow Analysis around Hydraulic Excavation Damaged Zone)

  • 박종성;류동우;류창하;이정인
    • 터널과지하공간
    • /
    • 제17권2호
    • /
    • pp.109-118
    • /
    • 2007
  • 굴착손상영역(EDZ)은 굴착으로 인해 현지 암반이 역학적으로 손상을 입게 되어 응력상태, 변위상태, 암반의 안정성, 지하수의 흐름상태 등에 변화가 일어나는 영역을 의미한다. EDZ의 역학적 특성과 관련한 많은 연구들이 수행되었지만, EDZ에서의 지하수 유동 특성에 관한 연구는 아직 부족한 수준이다. 본 연구에서는 굴착으로 인한 수리-역학 상호작용(coupling)에 의해 굴착면 주변의 수리적 간극값이 변하는 영역을 수리적 굴착 thstkdduddudr이라 정의하고, 이를 3차원 분리단열망(DFN)에 적용시켜 보았다. 이를 통해 수리적 간극변화가 3차원 불연속 망에서의 전반적인 지하수 유동에 미치는 영향을 파악하였다. 또한 3차원 DFN 지하수 유동 해석 시 주로 이용되는 수두 조건과 유량 조건의 적용성을 고찰하였다. 해석 결과 수리-역학적 상호거동에 의해 발생하는 굴착면 주변의 수리적 간극변화는 터널 내부로 유입되는 유량에 큰 영향을 미치는 것으로 나타났다. 또한 DFN 해석 시 다양한 경계조건에 따른 상이한 결과를 토대로 보다 합리적인 경계조건 설정에 대한 방향을 제시하였다. 마지막으로 실제 현장에서 수리해석을 실시한 자료를 바탕으로 수리적 간극 값의 변화를 고려할 때와 고려하지 않을 때의 유입유량 차이를 통해, 3차원 지하공동의 지하수 유동해석 시 수리적 간극 값의 변화를 고려하는 것이 보다 더 보수적인 결과를 나타내는 것을 확인하였다.

작업환경측정 지정기관의 분석실 현황 및 분석결과의 신뢰성에 영향을 주는 요인 (Current status of working environment monitoring the designated organization's laboratory and factors affecting reliability of the analysis results)

  • 김기웅;박해동;김성호;노지원;황은송;정은교;조기홍
    • 한국산업보건학회지
    • /
    • 제28권1호
    • /
    • pp.108-116
    • /
    • 2018
  • Objectives: This study investigated to the analytical work environment, analyst's expert and status of analytical instrument in the designated organization's laboratory for measuring work environment, and carried out to ensure reliability of analytical results. Methods: This study was conducted by 114 analysts who work in designated organization's laboratory for measuring work environment. Information on the working environment and personal characteristics of the analysts were collected using a self-reported questionnaire and were analyzed using the SPSS program through analysis of frequency and t-test. Results: The speciality of subjects was occupational health(57.0%), environmental health(38.6%) and environmental engineering(4.4%), and they had a higher level of academic ability than workers in other industries. Analysts had to handle a large number of sample analysis and many tasks other than analytical work. The analysts answered that it was difficult to analyze organic substances than inorganic substances, and the difficult parts were the analytical methods setting of new substances(55.3%), instrument analysis(24.6%) and principle of analysis(23.7%). Analytical instruments mainly have legally required instruments. The difficulty of the analysis is solved from the senior analyst in the laboratory and analytical information is mainly exchanged through seminar organized by the Association of Occupational Health Analysts. The analysts who are planning to move or considering the company were 48.2%, and the reasons for moving the company were difficult to work(14.0%), low salary(9.6%), employment type(8.8%) and job stress(7.0%). Conclusions: The conclusions of our study were that it was possible to secure reliability by solving the problems such as implementing professional education to improve expertise of analysts, strengthening analytical instruments through institutional improvement and improving work environment.

자돈의 행동에 미치는 열환경 분석 (Analysis of Heat Environment in Nursery Pig Behavior)

  • 송준익;최홍림;전중환;전병수;강희설;이은솔;박규현
    • 한국축산시설환경학회지
    • /
    • 제15권2호
    • /
    • pp.131-138
    • /
    • 2009
  • 본 연구는 돼지의 체온 발산에 따른 행동에 근거하여 환경을 제어할 때 몸체에서 발산되는 체열과 환경의 온도차이를 이용하여 환경을 제어할 수 있는 방법을 모색하고자 하였으며, 열환경에서 얻어진 자료를 바탕으로 축사의 환경제어 시스템에 접목하고자 실시하였다. 연구의 결과를 요약하면 다음과 같다. 1. 환경온도에 따른 돼지의 행동을 칼라영상을 통하여 획득한 후 가시화 시스템 (열화상 프로그램)을 통한 행동상태를 고온, 적온, 저온기로 분류하였다. 2. 영상처리 시스템의 하드웨어를 적외선 CCD 카메라, 영상처리 보드DIF(TH3100) 모델과 컴퓨터는 400Hz, 128M, 586 Pentium로 구성되었으며, 프로그램은 C++ 언어로 작성되었다. 3. 영상처리시스템을 온도에 따라 분류했던 결과 저온, 적온, 고온으로 분류되어 돈사내 환경제어 시스템에 응용이 가능할 것으로 판단되었다. 4. 사료섭취량은 저온구가 다른 환경온도에 비하여 사료를 많이 섭취하였던 반면에 종료체중과 일당증체량에서는 낮게 나타났다 (p<0.05).

  • PDF

2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구 (A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer)

  • 박동소
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5284-5289
    • /
    • 2011
  • 본 연구에서는 대학 캠퍼스의 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열관류율(U-value) 평가를 수행하였다. 교육시설의 주요 창호 재료로 적용된 알루미늄은 열전도율이 175 $kca{\ell}/m^2h^{\circ}C$ 정도로 플라스틱 소재의 창틀과 비교할 때, 매우 불리하여 기존 교육시설에 설치된 알루미늄 창호는 열교를 통한 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 알로이 합금 창호의 열관류율 평가에 관한 연구를 수행하여 다음의 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물 에너지절약설계기준의 남부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 시물레이션을 통한 해석 결과 열관류율은 알루미늄 합금 창호 U= 9.631 W/$m^2K$, 복층유리 U= 2.382 W/$m^2K$로 여름철과 겨울철 동일한 해석 결과치가 산출되었다. (2) 열관류율 해석결과를 "건축물의 에너지절약설계기준"의 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반 복층창 단열성능기준인 U=4.0 W/$m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열손실이 발생됨을 보여 주고 있다.

OSGi 기반 USB 단말기 시스템을 이용한 ADHD 간편검사 (ADHD Simple Examination Using an OSGi Base USB Terminal System)

  • 한상석;이창구
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.664-673
    • /
    • 2008
  • 최근 유비쿼터스가 최대의 화두로 떠오르고 있다. 새로운 지식 정보와 경쟁력 강화를 위한 유비쿼터스 컴퓨팅 혁명은 기술 활용 체제라는 새로운 패러다임 전환과 이에 따른 대대적 변화를 예고하고 있다. 또한, u-러닝 기반여건과 학습 장애상황들을 극복하기 위해서는 기술 공학적으로 상당히 접근되어 있는 시스템과 생활 지도 측면의 검사가 반드시 필요하다. 본 논문에서는 OSGi(Open Service Gateway Initiative)에 기반을 둔 USB(Universal Serial Bus) 단말기 시스템을 이용하여 초등학교에서 증가 추세이며 반드시 해결해야 할 주의력 결핍 및 과잉장애(Attention Deficit Hyperactivity Disorder, 이하 ADHD)에 대한 간편검사를 구현하였다. OSGi 기반 USB 단말기 시스템은 다수의 USB 단말기들과 OSGi를 탑재한 서버가 고속의 USB 버스를 이용하여 네트워크를 구축한 다양한 유비쿼터스 시스템으로 정보의 보호, 네트워크의 안전성, 비용 절감 및 유지 보수가 용이함, 주의 집중력 향상 등의 장점이 있고, ADHD는 조기 진단과 치료가 절실하기 때문에 본 논문에서 다루게 되었다. OSGi 기반 USB 단말기 시스템을 활용한 ADHD 간편검사를 통하여 지필 검사의 단점을 보완하고 컴퓨터를 이용한 검사의 문제점을 해결할 수 있었으며, 학생 지도에 도움을 줄 수 있는 시스템 적용을 확인하였다. 본 논문 결과에 비추어 학교에서 공식적으로 실시하는 인성검사나 지능검사와 일반 시험문제 풀이 그리고 수준별 학습용 시스템, 맞춤형 설문 조사 프로그램, 장애인을 위한 학습 시스템, 다수가 같이하는 게임시스템으로도 사용이 가능하다.

유자과즙 추출물의 생리활성 및 항균활성에 관한 연구 (The Study of Physiological and Antimicrobial Activities on the Citrus Junos Extracts with its Textures and Skin)

  • 이송희;이무성
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.67-74
    • /
    • 2017
  • 본 연구는 유자의 과즙을 $50^{\circ}C$ 의 열수 추출물과 70%에탄올 추출물을 이용하여 항산화 효능과 항균효과를 2016년 11월부터 2017년 3월까지 실험하여 분석하였다. 실험결과는 모두 3회 반복 측정하여 평균값(mean)과 표준편차(standard deviation, SD)로 나타내었다. 연구 결과 총 polyphenol과 Tannin함량은 70%에탄올 추출물에서 $7.8{\pm}0.02mgGAE/g$, $9.9{\pm}0.01mgTAE/g$으로 열수 추출물보다 높은 함유량을 나타냈으며, DPPH radical의 소거능과 ABTS radical 소거능역시 70% 에탄올 추출물에서 농도가 10000 ppm일 때 각각 $46.1{\pm}4.76%$, $37.1{\pm}1.23%$로 열수 추출물보다 높게 나타났다. 항균효과에서는 C. albicans를 제외하고 모든 균에서 항균활성을 나타내었으며, 농도 25 mg/disc에서 E. coli는 $50^{\circ}C$ 열수추출물에서 $18{\pm}1.73mm$, S. epidermidis와 S. aureus는 70% 에탄올 추출물 에서 $17{\pm}4.36mm$, $19{\pm}2.86mm$로 열수추출물과 에탄올 추출물 모두 높은 항균력이 있음을 확인 하였다. 이와 같은 결과로 보았을 때 유자과즙추출물을 이용하여 비누, 샴푸 또는 두피개선제등 미용 또는 피부 관련 향장소재로서 활용할 수 있는 기초자료로서 충분한 가치가 있을 것으로 판단된다.

UPS 파워 팩 내부 연료전지의 냉각특성에 대한 수치 해석 (A Study on Numerical Analysis for Internal PEMFC Cooling of Power Pack for UPS)

  • 송준석;김병헌
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.527-535
    • /
    • 2017
  • 연료전지 배터리 하이브리드 UPS용 연료전지 파워 팩 내부에 설치한 연료전지의 화학반응에 의해 생성되는 열을 제거하는데 어려움이 있다. 열을 제거하지 못할 경우 연료전지의 내구성과 성능에 영향을 끼쳐 수명 단축의 원인이 된다. UPS용 연료전지 파워 팩 제작을 위하여 연료전지의 적절한 냉각 방법을 선정하고 제시하는 것이 본 연구의 목표이다. 냉각방법 선정을 위해 냉각 성능에 영향을 주는 각각의 설계 인자를 변화시키면서 연구를 수행하였다. 전산해석은 상용프로그램인 COMSOL Multiphysics로 수행하였다. 먼저 연료전지 스택의 냉각 팬의 위치를 상단과 하단에 배치했을 때 1 kW급 연료전지 스택 표면온도를 비교하였으며, 각각의 위치에 따른 냉각 팬의 회전속도를 2,500, 3,000, 3,500, 4,000 RPM으로 변경하여 적절한 냉각 팬의 속도를 결정하였다. 또한 파워 팩 외부에서 내부로 들어오는 공기의 입구인 그릴의 타공면적을 달리하여 내부로 들어오는 공기의 유량이 냉각에 미치는 영향을 비교하였다. 본 연구는 UPS용 연료전지 파워 팩 내부 연료전지의 열관리 기술개발에 효과적으로 활용될 수 있을 것으로 판단된다.

화재시 축력비에 따른 매입형 합성기둥의 내화성능에 대한 해석적 연구 (An Analytical Study on Encased Steel Composite Columns Fire Resistance According to Axial Force Ratio)

  • 김예솜;최병정
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.97-107
    • /
    • 2020
  • 본 연구에서는 화재시 매입형 합성기둥의 높은 축력비에 따른 내화성능을 알아보기 위해 유한요소해석 프로그램(ANSYS)을 통한 해석을 실시하였다. 온도에 따른 응력-변형률 곡선을 적용하여 ASTM E 119 가열곡선과 축력비 0.7, 0.6, 0.5에 따른 과도상태 열전달해석 및 정적구조해석을 실시하였으며, 해석조건과 동일한 조건에서의 재하가열실험을 실시하였다. 또한, 기준식(Eurocode 4)에 따라 가열시간에 따른 합성기둥의 공칭압축강도를 산정하고, 축력비로 나타내어 해석값 및 실험값과 비교하였다. 해석 및 실험과 기준(Eurocode 4)을 통해 가열시간에 따른 단면별 온도분포를 확인하고, 이에 따른 내화성능을 측정해 비교분석하였다. 유한요소해석 결과 축력비 0.5에서는 내화시간 180분으로 실험값과 유사한 값이 도출된 반면, 축력비 0.6, 0.7에서 내화시간 150분과 60분이 도출되어 실험결과에 비해 다소 높은 결과가 도출된 것을 알 수 있었다. 그리고 기준식(Eurocode 4)에 따라 산정한 축력비에 따른 내화시간이 실제 실험값에 비해 다소 낮게 평가하고 있다는 것을 확인하였다. 그러나 축력비 0.7에서는 기준(Eurocode 4)이 실험값에 비해 다소 높게 평가하는 것을 확인하였다. 이에 따라 고축력에서의 매입형 합성기둥의 내화특성(시간-축력비 관계)을 확인하고, 도출된 매입형 합성기둥의 실험 및 해석데이터를 Eurocode기준의 검증의 자료로 활용할 수 있을 것으로 보인다.