• 제목/요약/키워드: Energy use behavior

검색결과 395건 처리시간 0.029초

Corrosion Characteristics of HT-9 in 500℃ and 650℃ Pb-Bi Liquid Metal

  • Song, T.Y.;Cho, C.H.
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.94-98
    • /
    • 2006
  • The next generation nuclear power reactor will use Pb-Bi as the cooling material. The steel structure materials such as HT-9 used in the reactor suffer from corrosion when they are exposed to high temperature Pb-Bi. Therefore corrosion should be prevented to use Pb-Bi as the coolant material without any safety problem. One method is to control the oxygen content in Pb-Bi. An appropriate amount of oxygen in Pb-Bi can produce a thin oxide layer on steel, and this layer protects the steel from corrosion attack. Since the required oxygen content in Pb-Bi is in the range of $10^{-5}$ to $10^{-7}$ wt%, this small oxygen content can be controlled by flowing a mixture of hydrogen gas and water vapor. The stagnant corrosion test of HT-9 samples was performed by controlling the oxygen content up to 2,000 hours. The corrosion behavior of HT-9 was analyzed at the temperatures of $500^{\circ}C$ and $650^{\circ}C$ with a reduced condition and a oxygen content of $10^{-6}$ wt%.

Comparative experimental assessment of seismic rehabilitation with CFRP strips and sheets on RC frames

  • Kakaletsis, D.J.
    • Earthquakes and Structures
    • /
    • 제10권3호
    • /
    • pp.613-628
    • /
    • 2016
  • The effectiveness of the use of modern repair schemes for the seismic retrofit of existing RC structures were assessed on a comparative experimental study of carbon fiber-reinforced polymer (CFRP) strips and sheets for the repair of reinforced concrete members of RC frames, damaged because of cyclic loading. Two virgin, single - story, one - bay, 1/3 - scale frame specimens were tested under cyclic horizontal loading, up to a drift level of 4%. Then, virgin specimens, B and F, respectively, were repaired and retested in the same way. One, specimen RB, was repaired with epoxy injections and CFRP strips and one, specimen RF, was repaired with epoxy injections and CFRP sheets. The two specimens are used to examine the differences between the structural behavior of frames repaired using CFRP strips and frames repaired using CFRP sheets. Both qualitative and quantitative conclusions, based on the observed maximum loads, loading and reloading stiffness, hysteretic energy absorption and failure mechanisms are presented and compared. The repaired frames recovered their strength, stiffness and energy dissipated reasonably. The use of CFRP sheets was found more effective than CFRP strips, due to the proper anchorage.

Dynamic behavior of a seven century historical monument reinforced by shape memory alloy wires

  • Hamdaoui, Karim;Benadla, Zahira;Chitaoui, Houssameddine;Benallal, Mohammed Elamine
    • Smart Structures and Systems
    • /
    • 제23권4호
    • /
    • pp.337-345
    • /
    • 2019
  • This work resumes a research that proposes the use of the technique based on the dissipation energy of the shape memory alloy (SMA) ties. It focuses principally on the assessment of the effectiveness of the use of these smart materials on displacements, accelerations and the stresses of the minaret of the great mosque of Ajloun in Jordan. The 3-D finite element model of the minaret is performed by the ANSYS software. First of all, the proposed model is calibrated and validated according to the experimental results gathered from ambient vibration testing results. Then, a nonlinear transient analysis is considered, when the El-Centro earthquake is used as the input signal. Different simulating cases concerning the location, number and type of SMA devices are proposed in order to see their influence on the seismic response of the minaret. Hence, the results confirm the effectiveness of the proposed SMA device.

와류식 교반기를 이용한 폴리프로필렌 입자의 혼합 거동에 대한 수모델 연구 (Water Model Experiments of the Mixing Behavior of Polypropylene Particles by Vortex Stirrer)

  • 정재용;이준호;이형철;기준성;황진일
    • 대한금속재료학회지
    • /
    • 제50권2호
    • /
    • pp.122-128
    • /
    • 2012
  • Water model experiments were carried out to understand the mixing behavior of reducing agents in molten slag through vortex stirrer, which makes use of a gravitational energy to mix reducing agent in the molten slag without imparting artificial energy. At a water flow rate of 6 L/min vortex was not generated, and a stable vortex was formed when the water flow rate was 7 L/min or higher with the present experimental apparatus. Water level increased linearly with increasing the water flow rate. In the upper vortex region, the vertical and horizontal velocities slightly decreased with increasing the water flow rate, whereas those in the lower vortex region increased remarkably. Accordingly, strong mixing behavior was obtained in the lower vortex region. Owing to the strong centrifugal force, particles move downwards with approaching the funnel wall. When 40 grams of polypropylene particles added to the lower vortex, they were instantaneously mixed well.

Experimental investigation of thin steel plate shear walls with different infill-to-boundary frame connections

  • Vatansever, Cuneyt;Yardimci, Nesrin
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.251-271
    • /
    • 2011
  • To make direct comparisons regarding the cyclic behavior of thin steel plate shear walls (TSPSWs) with different infill-to-boundary frame connections, two TSPSWs were tested under quasi-static conditions, one having the infill plate attached to the boundary frame members on all edges and the other having the infill plate connected only to the beams. Also, the bare frame that was used in the TSPSW specimens was tested to provide data for the calibration of numerical models. The connection of infill plates to surrounding frames was achieved through the use of self-drilling screws to fish plates that were welded to the frame members. The behavior of TSPSW specimens are compared and discussed with emphasis on the characteristics important in seismic response, including the initial stiffness, ultimate strength and deformation modes observed during the tests. It is shown that TSPSW specimens achieve significant ductility and energy dissipation while the ultimate failure mode resulted from infill plate fracture at the net section of the infill plate-to-boundary frame connection after substantial infill plate yielding. Experimental results are compared to monotonic pushover predictions from computer analysis using strip models and the models are found to be capable of approximating the monotonic behavior of the TSPSW specimens.

암모니아/메탄 예혼합 대향류 대칭화염에 관한 수치해석적 연구 - Part I 소화거동의 특성 (Numerical Study on the NH3/CH4 Symmetric Premixed Counterflow Flames - Part I Characteristics of Extinction Behavior)

  • 진은서;이기만
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.47-58
    • /
    • 2023
  • Experimental data conducted by Colson et al. and numerical data conducted in this study were compared through counterflow flames to understand of the characteristic of basic flame about mixture of ammonia/methane. In order to use the suitable numerical mechanism, the validation was performed using total four mechanisms and the Okafor's mechanism showed satisfactory experimental results. The extinction boundary of the stability map could be explained through the effective Lewis number and the trend of LeD. The extinction behavior of the flame was different under the lean and rich symmetric conditions and it was investigated by the major variables, global strain rate (ag) and mole fraction of ammonia (ΩNH3).

Study of Electrochemical Cs Uptake Into a Nickel Hexacyanoferrate/Graphene Oxide Composite Film

  • Choi, Dongchul;Cho, Youngjin;Bae, Sang-Eun;Park, Tae-Hong
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권2호
    • /
    • pp.123-130
    • /
    • 2019
  • We investigated the electrochemical behavior of an electrode coated with a nickel hexacyanoferrate/graphene oxide (NiPB/GO) composite to evaluate its potential use for the electrochemical separation of radioactive Cs as a promising approach for reducing secondary Cs waste after decontamination. The NiPB/GO-modified electrode showed electrochemically switched ion exchange capability with excellent selectivity for Cs over other alkali metals. Furthermore, the repetitive ion insertion and desertion test for assessing the electrode stability showed that the electrochemical ion exchange capacity of the NiPB/GO-modified electrode increased further with potential cycling in 1 M of $NaNO_3$. In particular, this electrochemical treatment enhanced Cs uptake by nearly two times compared to that of NiPB/GO and still retained the ion selectivity of NiPB, suggesting that the electrochemically treated NiPB/GO composite shows promise for nuclear wastewater treatment.

SUMMARY OF THE RESULTS FROM THE PHEBUS FPT-1 TEST FOR A SEVERE ACCIDENT AND THE LESSONS LEARNED WITH MELCOR

  • Park, Jong-Hwa;Kim, Dong-Ha;Kim, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.535-550
    • /
    • 2006
  • The objectives of this paper are twofold to summarize the new findings and confirmed results from the Phebus FPT-1 experimental data and to report useful information to MELCOR users regarding the better use of MELCOR. For the core damage behavior, the early stage of a melt progression was predicted well; however, the late phase models, concerned with fuel dissolution, oxide cladding failure, fuel slumping, rubble debris heat up, effects of burn-up fuel, and so on, still showed limitations in MELCOR. For the fission product behavior, the comparison showed unexpected phenomena, various limitations, unresolved issues, and even absence of models. The issues summarized in this study have revealed the main areas where our endeavors need to be intensified in order to improve our understanding of severe accident phenomena. From the analysis of the Phebus FPT-1 test results, not only new core damage features, such as foaming or core expansion, but also possible new fission product release patterns due to effects from a high burn-up fuel have raised alternative challenging phenomena that should be solved in the next severe accident research phase.

연속주조 압출 ZK60A 합금의 고온 기계적 특성 (High Temperature Mechanical Properties of Continuous Cast and Extruded ZK60A Alloy)

  • 안병민
    • 소성∙가공
    • /
    • 제23권3호
    • /
    • pp.178-183
    • /
    • 2014
  • Continuous casting is a process where molten metal is solidified into a semi-finished billet on a large scale with either a rectangular or round cross section for subsequent processing. The use of continuous casting provides an opportunity for producing material on a practical industrial scale with lower cost than conventional casting. In the current study, the material was fabricated by continuous casting and subsequent extrusion. Tensile tests were conducted on continuous cast ZK60A after extrusion over a range of strain rates at temperatures from 473K to 623K. The alloy exhibits a quasi-superplastic behavior with a maximum recorded elongation of ~250% at 523K when tested with an initial strain rate of $10^{-5}/s$. The experiments give a strain rate sensitivity exponent of 0.3~0.4 and an activation energy of 108 kJ/mol. From the current investigation, it was found that the high-temperature plastic flow of the ZK60A is controlled by a dislocation viscous glide mechanism.

Accelerated Prediction Methodologies to Predict the Outdoor Exposure Lifespan of Galvannealed Steel

  • Kim, Ki Tae;Yoo, Young Ran;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • 제18권3호
    • /
    • pp.86-91
    • /
    • 2019
  • Generally, atmospheric corrosion is the electrochemical degradation of metal that can be caused by various corrosion factors of atmospheric components and weather, as well as air pollutants. Specifically, moisture and particles of sea salt and sulfur dioxide are major factors in atmospheric corrosion. Using galvanized steel is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steel is widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance relative to iron. The atmospheric corrosion of galvanized steel shows complex corrosion behavior, depending on the plating, coating thickness, atmospheric environment, and air pollutants. In addition, corrosion products are produced in different types of environments. The lifespans of galvanized steels may vary depending on the use environment. Therefore, this study investigated the corrosion behavior of galvannealed steel under atmospheric corrosion in two locations in Korea, and the lifespan prediction of galvannealed steel in rural and coastal environments was conducted by means of the potentiostatic dissolution test and the chemical cyclic corrosion test.