• 제목/요약/키워드: Energy transformation

검색결과 660건 처리시간 0.027초

1920년대 소비에트 구성주의 패션에 관한 연구 (A Study on Soviet Constructive Fashion in 1920s)

  • 조윤경;금기숙
    • 복식
    • /
    • 제36권
    • /
    • pp.183-203
    • /
    • 1998
  • The wave of Avant-garde swept away all in the unique social background so called 'October Revolution' and the early 1900 Russian society which was able to absorb and accept anything. The Russian avant-garde has been affected by the Cubism and the Futurism those had peculiarly appeared in the early twentieth century, spreaded out to three spheres: the Suprematism, the Rayonism and the Constructivism. The Russian Constructivism has appeared in this background, concretely and ideally ex-pressed the ideology of the revolution into the artistic form and made an huge influence to the whole Russian society. The Constructivist like Tatlin, naum Gabo, Pevaner, Rodchenko, Stepanova, Popova and Exter gave great effect on the Soviet Constructive fashion design in 1920's after the Revolution. The Soviet costume in 1920s hold in common the characteristicss of the Constructive graphic as it is, geometrical and abstractive form, energetic and motility. In fashion design, these graphic qualities have been showed as the application of geometrical form and architectural image, physical distortion and transformation. And in textile design, the simple, dynamical presentation has been appeared. We can classify the Soviet costume at this time into three occasions. The first term is from late 1910 th mid 1920, and it is altered from folk costume design to modern one. With Lamanova as the first on the list, using the folk mitif, the Constructive expression of simple form has been gradually revealed in design. Designers like Makarova, Pribylskaia and Mukhina produced the plane, simple chemise style with the decoration of the Russian traditional motif. From early to late 1920 is the second term, and it is at the pick of the most active processing of the Constructive design. Not only at the costume in daily life but also at the theatrical costume and textile, the con-structive design has been represented all avail-able fields. Many Constructivists including Stepanova, Popova, Exter and Rodchenko took part in the textile design and costume design so as to evlvo their aesthetic concept. The third term is from late 1920 to early 1930. The socialistic realism has dominated over the whole culture and art, the revolutionary dynamic motif has been presented also in textile design. The formative features of Soviet Constructive fashion design are; silhouette, from, motif, color and fabric. The first, the silhouette : a straight rectangular silhouetted has been expressed through the whole period and a volumed one with distorted human body shape has introduced in the theatrical costume design. The second, the form: many lengthened rectangular forms have been made at beginnings, but to the middle period, geometrical, architectural forms have been more showed and there are energy and movement in design. At the last period, only a partial feature-division has been seen. The third, the motif; no pattern or ethnic motif has been partly used at beginnings, a figure like circle, tri-angle has gradually appeared in textile design. At latter period, a real-existent motif like an airplane has been represented with graphing and simplicity. The fourth, the color ; because of insufficient dyeing, neutral color like black or grey color has been mainly covered, but after middle term, a primary color or pastel tone has been seen, contrast of the fabric; without much development of textile industry after the Revolution, thick and durable fabrics have been the main stream, but as time had going to the last period, fabrics such as linen, cotton, velvet and silk have been varously choesn. At the theatrical costume, new materials like plastics and metals that were able to accentuate the form. The pursuit of popularity, simplicity and functionalism that the basic concept of Constructive fashion is one of the "beauty" which has been searching in modern fashion. And now we can appreciate how innovative and epochal this Soviet Constructive fashion movement was.ement was.

  • PDF

하수처리장 내 나노 TiO2 입자 제거효율 예측을 위한 물질흐름모델 개발 (Development of A Material Flow Model for Predicting Nano-TiO2 Particles Removal Efficiency in a WWTP)

  • 반민정;이동훈;신상욱;이병태;황유식;김극태;강주현
    • 한국습지학회지
    • /
    • 제24권4호
    • /
    • pp.345-353
    • /
    • 2022
  • 산업과 생활환경에서 사용된 공학적 미세입자는 결국 하수처리장을 거쳐 수계로 배출되므로 미세입자의 수계 배출 제어에 매우 중요한 역할을 담당하고 있다. 그러나 다수 연구에서 하수처리장 유출수 내 미세입자의 농도가 무영향관찰농도(No Observed Effective Concentration, NOEC)를 빈번히 초과하고 있는 것으로 보고되고 있어 전통적인 하수처리 기능과 더불어 미세입자를 보다 효과적으로 제어할 수 있도록 하수처리장의 설계와 운영을 최적화시킬 필요가 있다. 이를 위해서는 하수처리장 내 단위공정별 특성 및 운전조건에 따른 미세입자의 거동특성과 제거효율에 대한 예측이 선행되어야 한다. 이에 본 연구에서는 하수처리장 내 각 공정 특성별 및 주요 운전조건의 영향에 따른 미세입자 제거효율예측을 위한 모델을 개발함으로써 하수처리장에서 미세입자를 보다 효율적으로 제어하기 위한 도구를 제공하고자 하였다. 개발 모델에서는 수처리 계통에서의 4개 단위공정(1차침전지, 생물반응조, 2차침전지, 및 총인처리시설)을 고려하고, 슬러지처리 계통은 농축, 소화, 탈수 공정 등의 다중 공정을 통합한 단일 공정으로 모의한다. 모의 대상 미세입자는 TiO2 (nano-TiO2)로서, 수중에서의 용해와 변환은 미미하므로 부유성 고형물과의 부착 기작만을 고려하였다. 부유성고형물에의 nano-TiO2 부착 기작은 고-액상 간 평형가정에 기반한 겉보기분배계수(Kd)를 매개변수로 반영하였으며 정상상태에서의 미세입자의 농도 및 부하를 공정별로 계산할 수 있도록 하였다. 아울러 개발 모델 구동의 편의를 위하여 MS 엑셀기반 사용자 인터페이스를 제작하였다. 개발 모델을 이용하여 주요 운전인자인 고형물체류시간(Solid Retention Time, SRT)이 nano-TiO2 제거효율에 미치는 영향을 파악하였다.

개발전략으로서 산업정책: 쿠바의 경험과 정책적 시사점 (Industrial Policy as a Development Strategy: Cuba' s Experience and Policy Implications)

  • 신범철
    • 국제지역연구
    • /
    • 제22권3호
    • /
    • pp.3-27
    • /
    • 2018
  • 이 논문은 쿠바의 기존의 발전 전략과 국가사회주의의 본질적 문제를 개선하기 위한 시장개혁 조처를 분석하고 발전전략으로서 산업정책의 효과성을 논의하였다. 국가사회주의의 계획 경제는 기본적으로 동기부여 체계(incentive system) 결여와 연성예산제약(soft budget constraint) 문제를 극복하기 쉽지 않다. 이 두 가지 문제는1990년대 주된 무역 대상국가인 소련과 동구 국가사회주의 국가의 몰락 초래하였다. 사회주의국가 블록의 몰락이후 쿠바는 식량부족, 에너지부족, 생필품 부족 등 심각한 경제위기에 봉착하였다. 이를 극복하기 위해 쿠바는 국가사회주의를 유지하는 수준에서 경제개혁을 단행하여 시장개혁 정책을 실행하고자 하였다. 특히, 수출주도형 산업정책으로 자유무역지대법을 통과시키고 강력한 외자 유치의 산업정책과 이를 통한 발전전략을 추진하였다. 그러나 마리엘특구 등 4개의 경제특구 설치에 의한 산업정책과 발전전략은 크게 성공을 거두지 못하였다고 평가되고 있다. 이는 기본적으로 이중적 고용과 임금, 그리고 이중화폐제도의 문제에서 비롯된다. 외국기업은 노동자를 쿠바의 고용청을 통해 간접적으로 고용하거나 해고할 수 있는 고용방식은 선진적인 인사 조직관리 기법 적용을 제한하게 되고 결국은 근로의욕 저하, 노동자의 생산성 하락과 효율성 하락으로 이어질 수 있다는 것이다. 또한 이중화폐제도로 인한 이중적 임금구조는 외국인투자기업에 인건비가 높이기 때문에 외국인이 쿠바에 적극적으로 직접투자를 꺼린 것이다. 또한 쿠바의 불균형 산업구조와 생산구조, 편중된 노동력 구조, 도심화와 농촌인구 슬림화, 농업생산의 중앙집권화 등으로 Lewis가 제안한 2부문모형인 아시아 농업주도 발전전략을 적용하기 쉽지 않아 보인다. 다시 말해, 쿠바는 산업정책을 통한 발전 전략을 수행하기 위해서 여러 가지 난점을 극복해야 할 것이다.

반응표면분석법을 이용한 루테늄 알루미나 메탈모노리스 코팅촉매의 암모니아 분해 최적화 (Optimization for Ammonia Decomposition over Ruthenium Alumina Catalyst Coated on Metallic Monolith Using Response Surface Methodology)

  • 최재형;이성찬;이준혁;김경민;임동하
    • 청정기술
    • /
    • 제28권3호
    • /
    • pp.218-226
    • /
    • 2022
  • 최근 선진국들은 수소경제 및 탄소중립 사회로의 전환을 위해 수소에너지의 수요가 급격히 증가하고 있으며, 이산화탄소(CO2)를 배출이 없는 친환경적인 수소(H2) 생산 기술에 대한 관심이 높아지고 있다. 본 연구에서는 암모니아(NH3) 분해 수소 제조를 위해 루테늄 알루미나(Ru/Al2O3) 분말 촉매와 함께 알루미나 졸(alumina sol)의 무기바인더(inorganic binder)와 메틸 셀룰로오스(methyl cellulose)의 유기바인더(organic binder)를 사용하여 딥 코팅(dip coating) 방법으로 루테늄 알루미나 메탈 모노리스 코팅 촉매를 제조하였다. 딥 코팅을 위한 촉매 슬러리의 최적 비율로 촉매와 무기바인더의 중량 비율을 1:1로 고정하여 유기바인더 0.1일 때 1회 딥 코팅 시 촉매 코팅양은 61.6 g L-1이다. 이때 메탈모노리스 표면에 코팅된 촉매 층의 균일한 두께 (약 42 ㎛)와 결정상을 주사전자현미경(Scanning Electron Microscope, SEM)과 X-ray 회절분석(X ray diffraction, XRD)을 통해 확인하였다. 또한, 암모니아 분해 수소 제조의 최적 공정조건을 찾고자 반응표면분석법(Response Surface Method, RSM)을 이용하여 반응온도와 공간속도의 독립변수에 따른 암모니아 전환율에 대한 수치 최적화 회귀식 모델을 계산하였다. 이러한 결과로부터 암모니아 분해 수소생산을 위한 상업적 규모의 공정운전 기본설계 자료로 활용이 가능하다.

용호비결 연단술의 분석심리학적 의미 (On the Secret Scripture of Dragon and Tiger (Yong-Ho-Bi-Gyeol)-a Jungian Commentary)

  • 신용욱
    • 심성연구
    • /
    • 제33권2호
    • /
    • pp.141-194
    • /
    • 2018
  • 용호비결은 조선 중기의 문신이던 정렴(1506~1549년) 선생이 저술한 일종의 선도(仙道) 수련서로 매월당 김시습의 용호론의 맥을 잇는 조선시대 가장 중요한 도교문헌의 하나라고 할 수 있다. 본 논문은 정렴 선생과 용호비결 판본에 대하여 소개하고 책의 제목인 용호(龍虎), 책의 내용 중 수단지도(修丹之道), 폐기(閉氣), 호흡법, 단전(丹田), 현빈일규(玄牝一竅)의 연금술적 내용을 분석심리학적 측면에서 살펴보았다. 용호(龍虎)는 정신양(psychoid) 단계에서 작용하는 변환의 요소로 이를 통하여 단(丹)이 만들어지는데 단(丹)은 메르쿠리우스이자 철학자의 돌로 연금술의 적화 단계를 의미하기도 한다. 정렴 선생은 단(丹)을 이루기 위하여 가늘고 긴 호흡을 통한 단전에의 집중을 강조하였는데 이를 폐기(閉氣)라고 한다. 폐기(閉氣)는 능동적으로 니그레도(nigredo) 상태로 들어가는 것으로 이때 우리의 정신은 외부로 향한 투사를 거두어들여 단전(丹田)을 향해 집중한다. 니그레도를 통한 지속적인 수련은 알베도(albedo) 상태로의 이행을 가능케 하며 이를 통해 투사에 의한 객체의 오염으로부터 정신이 자유로와져 마음의 중심이 자아(ego)로부터 자기(Self)로 옮겨간다. 현빈일규(玄牝一竅)란 노자가 곡신(谷神)으로 표현한 우주의 여성적 원리를 경험하고 이를 체화하는 것이다.

고령 지산동 73~74호분 출토 유리구슬의 제작 기법과 화학 조성 (The Chemical Composition and Working Techniques of the Glass Beads Excavated in the Jisan-dong No. 73-74 Ancient Tombs, Goryeong)

  • 김나영;김은아;김규호
    • 박물관보존과학
    • /
    • 제31권
    • /
    • pp.21-37
    • /
    • 2024
  • 본 논문은 중심 연대가 5세기로 추정되는 고령 지산동 73~74호분에서 출토된 유리구슬 43점의 미세구조를 관찰하고 화학 조성을 분석하여 대가야 유리 문화를 이해하고자 하였다. 가시적 특징 및 미세구조는 실체현미경과 전자현미경으로 관찰하고 화학 조성은 전자현미경에 부착된 에너지분산형분광기로 분석하였다. 분석 결과, 고령 지산동 유리구슬은 늘인 기법, 주조 기법, 접은 기법 등 다양한 성형 기법이 확인되며 대다수는 늘인 기법에 의해 성형된 것으로 확인되었다. 화학 조성은 포타쉬유리군 32.6%, 소다유리군 67.4%로 소다유리군이 우세하게 나타나며 소다유리군는 고알루미나유리, 네트론유리, 식물재유리 등으로 다양한 융제가 사용된 것으로 판단된다. 이와 같은 고대유리의 조성은 동일 시기의 백제문화권과 비교하여 포타쉬유리군의 점유율이 높은 특징을 보인다. 이는 한국 고대유리 문화가 포타쉬유리군에서 소다유리군으로 변화하였으나 지역 및 문화권에 따라 차이가 있음을 보여준다. 소다유리군는 고알루미나유리가 23.3%, 네트론유리가 43.0%, 식물재유리가 1.2%로 네트론유리가 우세하게 나타났다. 그러나 한국 소다유리의 주된 유형은 고알루미나유리이고 유리 용기, 금박구슬, 연주옥을 제외한 네트론유리와 식물재유리의 출현 시기가 늦은 편으로 알려져 있는 점과는 상반된 결과로 지산동 출토 유리구슬에 대한 과학적 분석 결과는 한반도의 고대유리의 유입과 변천에 대한 중요한 단서를 제공할 수 있을 것으로 기대할 수 있다. 발굴조사에서 순차적으로 조영된 것으로 확인된 73, 74, 74-1호분은 조영 시기에 따른 유리구슬의 조성은 크게 차이가 나타나지 않는다. 또한, 신분 계급에 따른 차등 사용에 대한 근거도 확인되지 않는다. 다만, 유리의 화학 조성은 색상과 밀접한 관련을 보이는 것으로 판단된다.

대학생의 학창경험이 사회 진출에 미치는 영향: 대학생활 활동 로그분석을 중심으로 (School Experiences and the Next Gate Path : An analysis of Univ. Student activity log)

  • 이은주;박도형
    • 지능정보연구
    • /
    • 제26권4호
    • /
    • pp.149-171
    • /
    • 2020
  • 대학생 시기는 실질적으로 직업선택을 해야 하는 시기이다. 우리 사회가 빠르게 고도로 발달하는 만큼, 직업은 다양화, 세분화, 전문화되어 대학생들의 취업 준비기간은 또한 갈수록 길어지고 있다. 본 연구는 대학생들이 학교 내외에서 하는 경험하는 다양한 활동들이 취업에 어떤 영향이 있을지 대학생들의 로그데이터를 중심으로 분석해 보았다. 실험을 위하여 학생들의 다양한 활동을 체계적으로 분류하고 활동 데이터를 6개의 핵심역량(직무전문성강화 역량, 리더십 및 팀웍 역량, 세계화 역량, 직무몰입 역량, 직업탐색 역량, 자율이행역량)으로 구분하였고, 여기서 구분된 6개의 역량 값이 취업여부(취업그룹, 미취업그룹)에 미치는 영향을 분석하였다. 분석 결과 6개의 역량 모두 취업집단과 미취업집단의 수준차이가 유의한 것을 확인할 수 있어 학교에서의 활동은 취업에 유의미함을 유추할 수 있었다. 다음으로 6개의 역량이 취업의 질적성과에 미치는 영향을 분석하기 위하여 6개의 역량수준을 상·하로 나누고, 첫연봉액을 기준으로 6개의 그룹을 만든 후 관계를 확인해 보았는데, 그 결과 6개의 역량 중 세계화역량, 직업탐색역량, 자율이행역량 수준이 높은 학생이 연봉을 기준으로 한 취업성과 또한 높은 것으로 확인되었다. 본 연구의 이론적 공헌은 다음과 같다. 첫 번째, 학창경험으로부터 추출할 수 있는 역량을 인사조직관리분야의 역량과 연결하며, 개인의 경력성공을 위해 대학생으로서 필요한 역량을 직업탐색역량과 자율이행역량을 추가하였다는 점이다. 두 번째, 활동로그의 실데이터 기반으로 각각의 역량을 측정하고 결과변수와 검증을 한 점이다. 세 번째, 양적성과(취업률)뿐만 아니라 질적성과(연봉수준)를 분석한 점이다. 본 연구의 실무적 활용은 다음과 같다. 첫 번째, 대학생들의 경력개발계획 수립 시 가이드가 될 수 있다. 전략이 없거나 균형을 갖추지 못한 또는 과도한 스펙을 쌓기는 지양하고 직업세계와 직무에 대한 분석을 바탕으로 자신의 강점을 표현할 수 있는 취업준비가 필요하다. 두 번째, 학교와 기업, 지자체, 정부 등 대학생들을 위한 행사를 기획하는 담당자는 대학생들이 필요로 하는 경험을 설계할 본 연구에서 제시한 6대 역량을 참고할 수 있다. 이벤트의 수요자인 대학생이 필요한 역량을 키우면서 하면서 각 기관의 목적을 더할 때 수요자와 공급자 모두 만족스러운 결과를 만들 수 있다. 세 번째, 디지털 대전환 시대, 국가의 균형발전을 구상하는 정부의 정책담당자는 대학생들의 호기심과 에너지를 대학생들의 역량개발과 국가의 균형발전을 함께 성취하는 방향으로 정책을 만들 수 있다. 기존에 없던 플랫폼서비스를 시도하고, 기존의 아날로그 상품이나 서비스와 기업문화를 디지털화 하는 데에는 많은 인력이 필요하며 디지털세대인 현 대학생들의 활약은 전 산업에서 촉매가 될 뿐 아니라 성공적인 경력개발을 위한 대학생들에게도 필요한 경험이라 사료된다.

민담 '주인집을 망하게 한 하인'의 분석심리학적 이해: 트릭스터 원형을 중심으로 (An Interpretation of the Folktale 'the Servant Who Ruined the Master's House' from the Perspective of Analytical Psychology: Centering on the Trickster Archetype)

  • 노명선
    • 심성연구
    • /
    • 제37권2호
    • /
    • pp.184-254
    • /
    • 2022
  • 본 논문을 통해 한국 민담 '주인집을 망하게 한 하인'의 심리학적 의미를 고찰하였다. 민담 속 주인과 하인의 대립은 보편적인 인간 정신의 문제로, 경화된 기존의 집단적 의식과 이를 보상하고 갱신하려는 새로운 의식의 대립으로 볼 수 있다. 다른 각도에서 설명해보자면 인간의 정신적인 측면과 본능적인 측면 사이의 혹은 의식과 무의식 사이의 대립이며, 자아와 그림자 사이의 대립이라고도 할 수 있다. 민담 속 주인은 애먹이는 막내 하인을 없애버리려 여러 차례 시도하지만, 하인은 꾀와 속임수를 써서 주인으로부터 음식과 말(馬), 막내 누이, 전 재산, 마침내 목숨까지 빼앗아 버리고, 이야기는 막내 하인과 막내 누이의 혼인 생활로 끝을 맺는다. 주인이 죽고 하인이 새로운 주인이 되는 대극반전(enantiodromia)은 낡은 집단적 의식이 파괴되고 집단적 무의식으로부터 올라온 새로운 의식이 지배적 위치에 서게 되는 것으로, 개인의 심리적 상황에서는 기존의 자아의 태도가 해소되고 새로운 태도로 변환되는 것으로 이해해볼 수 있다. 이야기의 중간 과정에서 하인은 그를 죽이려고 주인이 써준 등편지를 순박한 사람들을 이용해 새롭게 바꿔 써서 막내 누이와 혼인한다. 이 모습은 집단적 의식의 도덕관념에서는 부정적으로 이해될 수 있으나, 아낙네, 꿀장수, 배고픈 중으로 상징되는 조선 시대 집단적 의식에서 무시되어오던 정신요소를 통합하는 과정으로 볼 수 있다. 하인으로 대변되는 새로운 의식성은 기존의 틀에 구속받지 않는 트릭스터적 특성을 갖기에 집단적 의식에서 무시되어온 정신적 내용을 통합하여 조선 후기 집단적 의식에 대한 보상과 대안으로서 제시하는 요소라고 할 수 있다. 주인은 다시 하인을 죽이려고 하인을 가죽 부대에 넣어 나무에 매다는데, 가죽 부대 속에 들어가 매달렸더니 눈을 떴다는 하인의 속임수에 넘어간 소경이 대신 매달려 죽고 하인은 달아나게 된다. 주인과 하인의 대극 문제가 마침내 나무로 상징되는 전체 정신(Self)에 맡겨지자 소경이 제거되는 것은 트릭스터에 포함되어있는 맹목성, 어리석음, 탐욕적 요소를 구분하고 정화하려는 자기(Self)의 의도로 이해해볼 수 있다. 이런 과정들을 거쳐 집단적 의식의 새로운 변화 혹은 새로운 자아의 태도를 상징하는 하인은 기존의 문제들을 해결하고 주인의 자리에 서게 된다. 그러나 꾀 많은 하인의 활약상을 들으며 청중들은 유쾌함과 해방감을 느끼는 한편, 소경이 대신 죽고 주인집 식구가 몰살되고 하인이 주인이 되는 부분에서는 하인의 위험성과 통제 불가능에 대한 우려와 두려움의 감정을 경험하기도 한다. 해외 유화들에 등장하는 트릭스터들 역시 철저히 이기적이고 오직 욕구를 채우고 위험에서 빠져나가기 위해 무고한 존재들을 속이거나 죽게 만드는데, 이들 트릭스터를 처단하거나 교화하려는 노력은 허사로 돌아가고 그들은 달아나버린다. 그러므로 본 민담 역시 이런 원형적 그림자가 매우 위험하다는 것, 그리고 의식이 통제하거나 의식에 동화될 수 없다는 것을 알게 해주고, 그것을 외경하고 관조하도록 하는 목적 의미도 있다고 볼 수 있다. 트릭스터는 기존의 구조와 질서가 경화되었을 때 보상작용으로서 무의식으로부터 올라오는 재생시키는(revivifying) 자연 에너지의 비합리적 발현 양상이다. 그 현상은 기존의 집단적 정신의 입장에서는 파괴적이고 비도덕적일 수 있으나, 도덕적으로 규정할 수 없는 보다 근원적 정신인 집단적 무의식의 기능이라고 보아야 한다. 트릭스터 원형상으로 볼 수 있는 하인은 변환을 가져오는 존재로 파괴성과 창조성이라는 양면성과 모순성을 지니고 있다. 본 민담의 유화들의 결말은 여러 갈래인데 이는 트릭스터의 양면성으로 인해 청중의 마음 반응이 그만큼 다양하다는 것을 반영하며, 트릭스터 문제에 대한 무의식의 다양한 반응을 제시하는 것이기도 하다. 또한 트릭스터란 그만큼 결론이 안 나고 논란을 일으키는 모순덩어리 존재로 의식적 합리적 태도로 통제할 수 없다는 것, 우리 안의 트릭스터 원형에 대해 진지하게 관조할 수 있을 뿐이라는 것을 보여준다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF