• 제목/요약/키워드: Energy saving rate

검색결과 325건 처리시간 0.031초

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구 (A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency)

  • 최두성;도진석
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

세계 기후대별 High-Performance Buildings의 에너지 소비 원단위 평가 및 신기술 적용 동향 분석 연구 (Comprehensive Analysis of Energy Consumption Rate and New Technology Trend in High-Performance Buildings related with Different Climatic Zones)

  • 김철호;이승언;김강수
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.63-72
    • /
    • 2018
  • In this study, we analyzed high-performance building technologies through a case study of 65 high-performance buildings in the U.S., Europe, Asia and Oceania. In detail, we reviewed the international trend of building energy-saving technology and energy consumption per unit area by analyzing buildings constructed within a 10 year period(2008-018). The primary energy consumption was $48-440kWh/m^2$, and the average value was calculated as $169.3kWh/m^2$. Although some buildings received high certification ratings, they did not meet either Korean or international energy evaluation standards. The system analysis revealed that many energy-saving technologies show various application rates in different countries because the technologies possess different properties. Furthermore, small-area building groups tended to have less primary energy consumption than the medium and large-area buildings, but the area-energy relationship $R^2$ value was analyzed as 0.3161, indicating no clear proportional relationship. Therefore, we propose that it is necessary to maximize the energy savings of buildings by taking into consideration a region's code, climate, building usage, area and space-using patterns to reduce energy and greenhouse gas emissions.

부산시 에너지마일리지제 시범운영을 통한 가정용 전력 소비절감 효과분석 (Study on the effect of reducing consumption of domestic electric power by managing model energy mileage system in Busan)

  • 이은주;배민호;김재민;송국섭;곽노열;옥성애
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.934-939
    • /
    • 2009
  • To promote citizen's involvement in the GHG(Green House Gas) reduction policy, Busan city administration adopted an pilot energy incentive system called 'energy mileage'. The energy mileage system was designed to make energy end-users motivated to reduce domestic electricity use by providing financial rewards. Through the course of the pilot period, 5,3330 householders volunteerly participated the pilot system. About 66% of the participants managed to make energy saving against the same period of the previous year while 38.8% achieved the targeted reduction rate(i.e. over 10%) and received the equivalent rewards.

  • PDF

중앙난방시스템의 유량제어방식에 따른 제어특성 연구 (Control Characteristics with Flow Rate Control Methods in Central Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

태양광발전을 이용한 냉동.냉장창고용 냉수펌프의 에너지절감 기법 (Energy Saving Technique of Refrigeration Warehouse Cold Water Pump Using Photovoltaic Generation)

  • 김대균;전기영;이상집;정춘병;이훈구;한경희
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.92-99
    • /
    • 2005
  • 냉동 냉장창고용 냉수펌프 시스템을 태양광발전 시스템과 연계하여 펌프의 양정 및 유량의 변화에 따른 압력의 변화에도 불구하고 목표치 압력을 일정하게 제어할 수 있도록 하였다. BLDC 모터를 벡터제어 함으로써 각 운전속도의 영역에서 최대토크 운전 및 높은 신뢰성을 가능하도록 하여 냉동 냉장창고용 냉수 펌프 시스템의 에너지 절감 효과를 실현하였다.

에너지절약을 위한 상호련결된 반보호좌회전 교차로의 신호시간설계 (Traffic Signal Timing at Interconnected and Semi-Protected-Left-Turn Intersections for Energy Saving)

  • 김경환
    • 대한교통학회지
    • /
    • 제8권1호
    • /
    • pp.25-40
    • /
    • 1990
  • This study was undertaken to develop a traffic signal timing method for interconnected and semi-protected-left-turn intersections(the intersections which have left-turn signal but not exclusive left-turn lanes) on four-lane streets for energy saving and to computerize the method for the practical use. For this study, a probability model which could estimate the utilized time of the shared left-turn lane by through traffic during green period was developed based on field studies. The two left-turn treatments, leading and lagging left-turns, were tested for the intersections, and it can be concluded that the leading left-turn was more efficient for the normal urban streets on which through traffic is major traffic. Adopting the leading left-turn macro-models to estimate vehicular average delay and proportions of vehicles stopped at the intersections were developed. Using the two models as well as the idling fuel consumpution rate and the excess fuel consumption per stop-go speed change, a traffic signal timing method for the intersections for energy saving was developed and computerized. The method can be used for more than four-lane streets and for other measures of effectiveness such as minimum delay, minimum stop rates, etc.

  • PDF

에너지 저장 시스템 (ESS)용 배터리의 운전조건에 따른 성능 저하 및 태양광 연계형 ESS 모니터링 연구 (Performance Degradation of a Battery in an Energy Storage System (ESS) under Various Operating Conditions and Monitoring Study of ESS Connected with Photovoltaic)

  • 정윤이;정한주;정연기;이재영;이홍기
    • 한국수소및신에너지학회논문집
    • /
    • 제25권3호
    • /
    • pp.311-318
    • /
    • 2014
  • Performance degradation of a battery in 20 kWh energy storage system (ESS) under various operating conditions was studied. And energy saving of the ESS was also monitored by connecting with 20 kW photovoltaic (PV). PV-connected ESS saved 5~7% of energy consumption in 2013 compared to that without such system in 2012. As charge-discharge cycle increased, capacity decreased and the performance degradation was glaringly obvious after 40 cycles. And as charge and discharge rate increased, the performance degradation was more serious. After 50 charge-discharge cycles, a lot of degraded product was deposited on the surface of anode and cathode electrodes, and the cathode side was more contaminated. Therefore, in order to maintain the cell performance, it was more important to protect the degradation of the cathode side.

중규모 사무공간에서 조명에너지 성능평가를 위한 노모그래프 개발에 관한 연구 (Development of Nomographs for the Evaluation of Lighting Energy Performance in a Semi-infinite Office Space)

  • 김한성;고동환;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.73-80
    • /
    • 2003
  • The purpose of this study was to analyze daylighting performance in a semi-infinite size office space for lighting energy conservation. DOE2.1E was used for simulations for the model space of $12\times12\times2.6m$. Nomographs were developed which could simulate work plane illuminance, glare index, energy consumption rate and energy reduction rate for daylighting design. Major results of simulations are as follows ; 1) When blinds facing south were installed, 43% of workplane illuminance diminished, but the flare index didn't exceed the recommended max-glare value. 2) In a semi-infinite office space facing south. energy consumption rate in the case space of 500 lux workplane illuminance is larger then case space of 300 lux workplane illuminance. Therefore, energy reduction rate is increased when the semi-infinite office faces south and naintains 300 lux workplane illuminance level.

가변 유압모터를 이용한 전동지게차 리프트회생 효율에 관한 연구 (A Study on the Regeneration Efficiency of the Electric Forklift Using the Variable Hydraulic Motor)

  • 박용수;어영소;윤진수;도 찌 끄엉;한성민;신정우;유충목;안경관
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.26-32
    • /
    • 2020
  • In modern society, the energy-saving problem of industrial vehicles is economically and environmentally critical. Energy savings using the potential energy of forklifts are one of the viable solutions to resolving this problem. The basic concept of this study is to operate the hydraulic motor and recharge the battery using the flow rate from the cylinder when loading heavy objects and lowering the fork. To save energy, the torque and rotational speed of the generator should be optimized according to the load and descent speed to increase efficiency. To this end, we propose a system that optimizes energy saving efficiency by controlling the swashplate angle of the variable hydraulic motor through the GA(Genetic-Algorithm). The results were verified by building and comparing fixed motor models and variable motor models using the AMEsim. The results of the study show that the proposed optimized swashplate angle increases the energy saving efficiency by approximately 6%-8%, depending on the working conditions.