• 제목/요약/키워드: Energy generator

검색결과 1,837건 처리시간 0.032초

에스컬레이터용 전력변환장치 효율 개선에 관한 연구 (A Study on Efficiency Improvement of Power Conversion System for Escalator)

  • 조수억
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.525-529
    • /
    • 2016
  • In the case of a motor system that converts electrical energy into mechanical energy, the region of the motor and that of the generator coexists. In the case of an escalator, the ascending escalator is operated by the motor, whereas the descending escalator is operated by the generator according to the load. To evaluate the proposed method, this study reduces the power of the ascending escalator up to approximately 35% by sharing the regeneration power of the descending escalator. The loss of transfer power nearly exists in the case of the proposed method. Furthermore, the lifetime of the DC link condenser can be extended because it is connected in parallel, thus leading to a twofold increase in capacity.

A 16-bit adiabatic macro blocks with supply clock generator for micro-power RISC datapath

  • Lee, Hanseung;Inho Na;Lee, Chanho;Yong Moon
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1563-1566
    • /
    • 2002
  • A 16-bit adiabatic datapath for micro-power RISC processor is designed. The datapath is composed of a 3-read and 1-write multi-port adiabatic register file and an arithmetic and logic unit. A four-phase clock generator is also designed to provide supply clocks fer adiabatic circuits and the driving capability control scheme is proposed. All the clock line charge on the capacitive interconnections is recovered to recycle energy. Adiabatic circuits are designed based on efficient charge recovery logic(ECRL) and are implemented using a 0.35 fm CMOS technology. Functional and energy simulation is carried out to show the feasibility of adiabatic datapath. Simulation results show that the power consumption of the adiabatic datapath including supply clock generator is reduced by a factor of 1.4∼1.5 compared to that of the conventional CMOS.

  • PDF

Power Closed-loop Control of Switched Reluctance Generator for High Efficiency Operation

  • Li, Zhenguo;Gao, Dongdong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.397-403
    • /
    • 2012
  • This paper describes a control method of turn-on/off angles to improve the efficiency of the switched reluctance generator(SRG) with a power closed-loop control system, and the inner-loop of the system is current hysteresis control. The SRG control system is constituted by the PI power controller and the two-level current hysteresis controller. By measuring and analyzing the system losses of different reference powers, speeds and turn-on/off angles, selection strategy of optimal turn-on/off angles is discussed. The proposed method is simple, reliable, and easy to achieve.

부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안 (A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator)

  • 장미혜;신백식;송원진;김영민;김동용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성 (The Impulse Output Characteristics using Cascading Method of Compact Transformer)

  • 정종한;김휘영;홍정환;박구렬;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

다리우스 풍력터빈 발전기의 기동특성 (Starting Characteristics of Darrieus Wind Turbine)

  • 이규용;이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1018-1020
    • /
    • 2003
  • Wind-powered generator system converts wind energy into utilized electric energy. Wind power generator is classified into two categories, as horizontal or vertical axis turbine. The former is equipped with yawing mechanism which is subject to set the blade-face towards the wind direction. However, the latter does not need this mechanism, but this system needs a external power for starting. This paper deals with the method how to overcome such trouble and with the analysis of the starting characteristic and a field test with a prototype of the Darrieus wind generator was performed.

  • PDF

영구자석 동기발전기의 설계 및 시제품 특성 분석에 관한 연구 (A Study on Design and Performance Analysis of a Prototype Permanent Magnet Synchronous Generator)

  • 오진훈
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.75-80
    • /
    • 2014
  • The small wind turbines has the merits of setting up with low costs by individuals, and get the energy saving effects that, it has the secured, separate markets from the big range systems, and the developing of it is continuously proceeding. The objective of this paper is to provide the design characteristics analysis of a permanent magnet synchronous generator(PMSG) skewed for magnet of rotor, the main advantage to be explored with the use of a split core design is the reduction in manufacturing costs and its simplicity in manufacture, compared to the manufacturing costs of a core skew PM machine. This thesis is aiming mainly analyzing the characteristics of the prototype to verify through Finite Element Method(FEM) and tests.

저속 기어형 2MW급 풍력발전기 개념설계 (Conceptual Design of 2MW Wind Turbine Generator with Low-speed Gearbox)

  • 손영욱;김영찬;김용환;이응채;박인수;정진화;한경섭;전중환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.319-322
    • /
    • 2006
  • Under the national project for the development of 2MW wind energy convert system, we are under development of the prototype of 2MW wind turbine with low speed gearbox. This system adopts low speed gear box with planetary and spur gear and is pitch regulated variable speed type with the synchronous permanent magnet generator. The compromised size of generator in diameter and width are adopted to meet the structural design requirements. In this paper, the concept study for the type, the aerodynamic design for the blade and the details of load calculation will be presented. The detailed characteristics of the system will also be introduced.

  • PDF

A PERFORMANCE ASSESSMENT OF A BASE ISOLATION SYSTEM FOR AN EMERGENCY DIESEL GENERATOR IN A NUCLEAR POWER PLANT

  • Choun, Young-Sun;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.285-298
    • /
    • 2008
  • This study evaluates the performance of a coil spring-viscous damper system for the vibration and seismic isolation of an Emergency Diesel Generator (EDG) by measuring its operational vibration and seismic responses. The vibration performance of a coil spring-viscous damper system was evaluated by the vibration measurements for an identical EDG set with different base systems - one with an anchor bolt system and the other with a coil spring-viscous damper system. The seismic performance of the coil spring-viscous damper system was evaluated by seismic tests with a scaled model of a base-isolated EDG on a shaking table. The effects of EDG base isolation on the fragility curve and core damage frequency in a nuclear power plant were also investigated through a case study.

NEURAL NETWORK CONTROLLER FOR A PERMANENT MAGNET GENERATOR APPLIED IN WIND ENERGY CONVERSION SYSTEM

  • Eskander Mona N.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.656-659
    • /
    • 2001
  • In this paper a neural network controller for achieving maximum power tracking as well as output voltage regulation, for a wind energy conversion system(WECS) employing a permanent magnet synchronous generator, is proposed. The permanent magnet generator (PMG) supplies a dc load via a bridge rectifier and two buck-boost converters. Adjusting the switching frequency of the first buck-boost converter achieves maximum power tracking. Adjusting the switching frequency of the second buck-boost converter allows output voltage regulation. The on-times of the switching devices of the two converters are supplied by the developed neural network(NN). The effect of sudden changes in wind speed ,and/or in reference voltage on the performance of the NN controller are explored. Simulation results showed the possibility of achieving maximum power tracking and output voltage regulation simultaneously with the developed neural network controller. The results proved also the fast response and robustness of the proposed control system.

  • PDF